{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"5SJ4225-7HG41","brand":"Siemens","brandSlug":"siemens","productSlug":"5SJ4225-7HG41","canonicalUrl":"https://aoctrl.com/siemens/5SJ4225-7HG41","factsUrl":"https://aoctrl.com/api/mcp/products/5SJ4225-7HG41","rawCanonicalId":null},"summary":{"shortDescription":"Siemens SENTRON 5SJ4 series, 2-pole miniature circuit breaker, C-curve, 10 kA (EN 60898) / 15 kA (IEC 60947-2), 400 V AC, 60 V DC, 2 MW units wide.","salesMarkdown":"Its C-curve tripping characteristic means it handles inrush currents 5–10× the rated current before tripping — the standard choice for motor and transformer branch circuits where the starting surge exceeds a B-curve's tolerance. For a machine-tool panel fed from a transformer with a known 12 kA fault level, the 15 kA rating provides the headroom without cascading upstream. ## Voltage and duty coverage Rated 400 V AC and 60 V DC. The 2-pole series configuration breaks both legs, clearing DC arcs that a single-pole cannot. The 75 °C maximum matters when the breaker sits near heat sources — a transformer or drive in the same enclosure — without derating. The -40 °C floor covers unheated outdoor cabinets in cold climates. Protection class IP20 with connected conductors, IP40 in the handle range. The IP20 body is standard for enclosed panels; the IP40 handle area means the toggle is protected against tools ≥1 mm diameter. Sealable — a lockable cover over the toggle prevents unauthorised switching, required in safety-isolation circuits under lockout/tagout procedures. Listed as current production.","metaTitle":"Siemens 5SJ4225-7HG41 2-Pole MCB, C-Curve, 10 kA","metaDescription":"Siemens SENTRON 5SJ4225-7HG41 2-pole miniature circuit breaker, C-curve, 10 kA per EN 60898, 15 kA per IEC 60947-2. Active production, sourced to order.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":["2-Pole MCB (DIN Rail)"],"specifications":{"Depth":"70 mm","Width":"36 mm","title":"5SJ4225-7HG41","Height":"110 mm","Maximum":"75 °C","Minimum":"-40 °C","Sealable":"Yes","description":"Miniature circuit breaker 240 V 14kA, 2-pole, C, 25A, D=70 mm according to UL 489","Halogen-Free":"Yes","Silicon-Free":"Yes","Design Of Pole":"2P","Number Of Poles":"2","lifecycle_stage":"current","Fastening Method":"on standard mounting rail","Mounting Position":"any","at AC rated value":"400 V","at DC rated value":"60 V","Installation Depth":"70 mm","Product Brand Name":"SENTRON","Degree Of Pollution":"3","Product Designation":"Miniature circuit breakers","protection class IP":"IP20, with connected conductors, IP 40 in the handle range","Overvoltage Category":"3","Tunnel Terminals Top":"No","Vibration Resistance":"50 m/s² at 25 to 150Hz and 60m/s² at 35Hz (4sec)","Combined Terminal Top":"Yes","Design Of The Product":"Miniature circuit-breaker 5SJ4","Product Function Note":"Terminal tightening torque for Cu, 60/75°C; 3.5Nm/31lb.in","Tunnel Terminals Bottom":"No","Combined Terminal Bottom":"Yes","Suitability For Operation":"Mechanical engineering / industry","at DC rated value maximum":"60 V","Neutral Conductor Switching":"No","Number Of Modular Width Units":"2","Position Of Power Supply Cord":"Any","Tripping Characteristic Class":"C","according to EN 60898 rated value":"10 kA","Ambient Temperature During Operation":"max. 95% humidity","Supply Voltage Frequency Rated Value":"50 Hz","according to IEC 60947-2 rated value":"15 kA","installation environment regarding EMC":"Suitable for environment B (immunity to interference not applicable)","insulation voltage (Ui) at AC rated value":"440 V","Value Range Of The Supply Voltage Frequency":"50/60 Hz","vibration resistance according to IEC 60068-2-6":"±1 mm at 5 to 25 Hz; 50 m/s² at 25 to 150 Hz","Mechanical Service Life (Operating Cycles) Typical":"10 000","Product Extension Installable Supplementary Devices":"Yes","Tightening Torque With Screw-Type Terminals Maximum":"3.5 N·m","power loss [W] for rated value of the current at AC in hot operating state per pole":"2.9 W"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":"$228.50","stockQuantity":0,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/4ef0807793bfd6bfec4b16e634440e79.pdf","sourceUrl":"https://support.industry.siemens.com/webbackend/api/ProductSupport/TechnicalData?language=en&region=cn&productId=134131&mlfb=5SJ4225-7HG41"},"ai":{"faq":[{"question":"Is the 5SJ4225-7HG41 suitable for DC applications?","answer":"Yes, rated 60 V DC. The 2-pole design breaks both legs, which is necessary to clear a DC arc that a single-pole cannot extinguish reliably."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"icboms-matrix-langgraph","citationUrl":"https://aoctrl.com/siemens/5SJ4225-7HG41","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/siemens/5SJ4225-7HG41 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-08-11T15:51:03.652Z","lastPublished":"2026-08-11T15:51:03.652Z","indexable":true}}