{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"5SJ6532-7FC","brand":"Siemens","brandSlug":"siemens","productSlug":"5SJ6532-7FC","canonicalUrl":"https://aoctrl.com/siemens/5SJ6532-7FC","factsUrl":"https://aoctrl.com/api/mcp/products/5SJ6532-7FC","rawCanonicalId":null},"summary":{"shortDescription":"Siemens SENTRON 5SJ6532-7FC, miniature circuit breaker, 1P+N, C-curve, 32 A rated, 6 kA breaking capacity per EN 60898, 2 MW.","salesMarkdown":"## What it is and what it does The Siemens SENTRON 5SJ6532-7FC is a 1P+N miniature circuit breaker (MCB) with a C-curve trip characteristic, rated 32 A at 230 V AC single-phase and 250 V AC single-phase operation. It interrupts fault currents up to 6 kA per EN 60898 — that's the standard for residential and commercial final circuits, so it covers branch protection in distribution boards for lighting, socket outlets, and small appliance loads. ## What the ratings mean for fit C-curve trips between 5 and 10 times rated current — 160 A to 320 A magnetic release — which suits moderate inrush loads like small motors, fluorescent lighting, and transformers. The 32 A rating at 30 °C derates to 29.56 A at 40 °C and 28.16 A at 45 °C; if your panel runs hot, size the upstream protection accordingly. The 1P+N configuration switches the phase and the neutral, with neutral conductor switching built in. That's useful where you need to isolate both poles for maintenance or where local codes require switched neutral on the final circuit. DC rating is 72 V maximum — fine for control-circuit isolation on a 48 V or 60 V DC bus, but not for a 110 V DC string. ## Where it goes and how it mounts Snaps onto standard 35 mm DIN rail. The 36 mm width (2 modular units) fits a standard distribution board slot. Depth is 76 mm, installation depth 70 mm — check gland-plate clearance if the panel is shallow. Mounting position is any, so it works horizontally in a tight enclosure as long as the venting isn't blocked. IP20 with connected conductors — suitable for enclosed distribution boards, not for wet or washdown areas. Overvoltage category III and pollution degree 2 are typical for fixed-installation final circuits. ## Compliance and documentation Halogen-free and silicon-free construction — relevant for clean-room or sensitive-environment installations where outgassing matters. Sealable with a lead or tag for lockout/tagout. Mechanical service life is 10,000 switching cycles typical, which is standard for an MCB in normal branch-circuit duty.","metaTitle":"Siemens 5SJ6532-7FC SENTRON MCB, 1P+N, C-Curve, 32A, 6kA","metaDescription":"Siemens SENTRON 5SJ6532-7FC miniature circuit breaker, 1P+N, C-curve, 32A rated, 6kA breaking capacity per EN 60898. Active production. Quoted to order.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":null,"categoryPath":["1-Pole MCB (DIN Rail)"],"specifications":{"Depth":"76 mm","Width":"36 mm","title":"5SJ6532-7FC","Height":"90 mm","Maximum":"75 °C","Minimum":"-40 °C","Sealable":"Yes","description":"Miniature Circuit Breaker 6KA, 1+N-pole, C, 32A","Halogen-Free":"Yes","Silicon-Free":"Yes","Number Of Poles":"2","Type Of Voltage":"AC","lifecycle_stage":"current","Mounting Position":"any","Installation Depth":"70 mm","Product Brand Name":"SENTRON","Degree Of Pollution":"2","Product Designation":"Miniature circuit breaker","at AC / rated value":"32 A","protection class IP":"IP20, with connected conductors","Overvoltage Category":"III","Number Of Poles / Note":"1P+N","at 30 °C / rated value":"32 A","at 40 °C / rated value":"29.56 A","at 45 °C / rated value":"28.16 A","Suitability For Operation":"Residential buildings/infrastructure","Number Of Modular Width Units":"2","Tripping Characteristic Class":"C","at DC / rated value / maximum":"72 V","acc. to EN 60898 / rated value":"6 kA","Product Feature / Touch Protection":"No","supply voltage / at AC / rated value":"230 V","Product Function / Neutral Conductor Switching":"Yes","with single-phase operation / at AC / rated value":"250 V","Mechanical Service Life (Switching Cycles) / Typical":"10 000"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"stockQuantity":0,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/6ae38c4009aedc9276873a0ac416809f.pdf","sourceUrl":"https://support.industry.siemens.com/webbackend/api/ProductSupport/TechnicalData?language=en&region=cn&productId=1502733&mlfb=5SJ6532-7FC"},"ai":{"faq":[{"question":"What is the breaking capacity of 5SJ6532-7FC?","answer":"6 kA per EN 60898, which is the standard for residential and commercial final circuits."},{"question":"Will 5SJ6532-7FC drop into a panel specified around 5SL6516-6YA without rewiring?","answer":"Yes — same 36 mm width, same 76 mm depth, same 1P+N pole configuration, same DIN-rail mount. The difference is the trip curve (C vs B) and the rating (32 A vs 16 A). If the panel was wired for a 16 A B-curve, the 32 A C-curve will physically fit but the circuit protection must be re-evaluated for the higher ampacity and different trip characteristic."},{"question":"How do I get current pricing and availability for 5SJ6532-7FC?","answer":"Submit an RFQ through this listing. The part is sourced to order through independent distribution; pricing and stock are confirmed at quote time."},{"question":"What compliance documentation does Siemens provide for 5SJ6532-7FC?","answer":"The part is halogen-free and silicon-free, which supports RoHS and REACH compliance. The EN 60898 rating covers IEC certification. For specific UL or other agency documentation, request the manufacturer's declaration with your RFQ."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"icboms-matrix-langgraph","citationUrl":"https://aoctrl.com/siemens/5SJ6532-7FC","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/siemens/5SJ6532-7FC when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-08-11T15:51:03.652Z","lastPublished":"2026-08-11T15:51:03.652Z","indexable":true}}