{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"5SL3004-7KL","brand":"Siemens","brandSlug":"siemens","productSlug":"5SL3004-7KL","canonicalUrl":"https://aoctrl.com/siemens/5SL3004-7KL","factsUrl":"https://aoctrl.com/api/mcp/products/5SL3004-7KL","rawCanonicalId":null},"summary":{"shortDescription":"Siemens SENTRON 5SL3004-7KL miniature circuit breaker, 1P+N, C-curve, 4.5 kA breaking capacity per IEC/EN 60898-1, 1 modular width (18 mm), DIN rail mount.","salesMarkdown":"The C-curve trip characteristic means it holds up to 5–10× rated current for short-duration inrush, then trips magnetically above that threshold; this suits mixed resistive-inductive loads like lighting banks, small motor starters, and control transformers where the inrush isn't extreme. It occupies one modular width (18 mm) on DIN rail, so it fits standard consumer units and sub-distribution panels without crowding. The 76 mm depth plus 70 mm installation depth leaves clearance for wiring behind the panel door — standard for a 1-module MCB. Neutral conductor switching is built in, so no separate neutral bar is needed downstream for this pole. The sealable design allows a lock or tag to prevent unauthorized toggling — useful for safety isolation on a dedicated circuit.","metaTitle":"Siemens 5SL3004-7KL SENTRON MCB, 1P+N, C-Curve, 4.5 kA","metaDescription":"Siemens 5SL3004-7KL SENTRON miniature circuit breaker, 1P+N, C-curve, 4.5 kA per IEC/EN 60898-1. Active production. Quoted on request.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":["1-Pole MCB (DIN Rail)"],"specifications":{"Depth":"76 mm","Width":"18 mm","title":"5SL3004-7KL","Height":"90 mm","Maximum":"75 °C","Minimum":"-40 °C","Sealable":"Yes","Standard":"IEC/EN60898-1, GB/T10963.1","description":"CIRCUIT BREAKER 230V 4.5KA, 1+N-POLE/1MW, N LEFT C4","Halogen-Free":"Yes","Silicon-Free":"Yes","Design Of Pole":"1P+N","lifecycle_stage":"current","Fastening Method":"DIN rail","Mounting Position":"any","at AC rated value":"230 V","at DC rated value":"60 V","Installation Depth":"70 mm","Product Brand Name":"SENTRON","Degree Of Pollution":"2","Product Designation":"Miniature circuit breaker","protection class IP":"IP20, with connected conductors","Overvoltage Category":"III","Combined Terminal Top":"No","Design Of The Product":"Miniature circuit breaker compact","Energy Limitation Class":"3","Combined Terminal Bottom":"No","Suitability For Operation":"Residential buildings/infrastructure","Neutral Conductor Switching":"Yes","Number Of Modular Width Units":"1","Position Of Power Supply Cord":"Any","Tripping Characteristic Class":"C","according to EN 60898 rated value":"4.5 kA","Ambient Temperature During Operation":"-25...45°C: max. 85%rF, 45 60°C: max. 43%rF","Type Of Voltage Of The Operating Voltage":"AC","insulation voltage (Ui) at AC rated value":"250 V","with single-phase operation at AC maximum":"250 V","Value Range Of The Supply Voltage Frequency":"50/60 Hz","vibration resistance according to IEC 60068-2-6":"Yes","Mechanical Service Life (Operating Cycles) Typical":"4 000","Product Extension Installable Supplementary Devices":"Yes","power loss [W] for rated value of the current at AC in hot operating state per pole":"2 W"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"stockQuantity":0,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/7b2c96bf2f76229fb6729f4b0aa4d917.pdf","sourceUrl":"https://support.industry.siemens.com/webbackend/api/ProductSupport/TechnicalData?language=en&region=cn&productId=1354181&mlfb=5SL3004-7KL"},"ai":{"faq":[{"question":"Where can I buy 5SL3004-7KL and how is it quoted?","answer":"Sourced and quoted to order against an RFQ through independent distribution. Availability and current pricing are confirmed at quote time — no stock count or price is published here."},{"question":"Will 5SL3004-7KL drop into a panel designed for 5SL4106-7CC without rewiring?","answer":"Both are 1-module (18 mm) DIN-rail MCBs, so the mechanical footprint is identical. The 5SL3004-7KL is a 1P+N C-curve breaker; the 5SL4106-7CC is a different rating and curve. If the panel was wired for a 1P+N neutral-switching MCB, the 5SL3004-7KL will fit the same rail position and busbar arrangement — but verify the trip curve and amp rating match the circuit design before swapping."},{"question":"What compliance documentation does Siemens provide for 5SL3004-7KL?","answer":"The breaker is certified to IEC/EN 60898-1 and GB/T 10963.1. It is halogen-free and silicon-free. For RoHS, REACH, and UL documentation, the manufacturer provides declarations on request through the standard compliance portal."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"icboms-matrix-langgraph","citationUrl":"https://aoctrl.com/siemens/5SL3004-7KL","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/siemens/5SL3004-7KL when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-08-11T15:51:03.652Z","lastPublished":"2026-08-11T15:51:03.652Z","indexable":true}}