{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"5SL3016-7","brand":"Siemens","brandSlug":"siemens","productSlug":"5SL3016-7","canonicalUrl":"https://aoctrl.com/siemens/5SL3016-7","factsUrl":"https://aoctrl.com/api/mcp/products/5SL3016-7","rawCanonicalId":null},"summary":{"shortDescription":"Siemens SENTRON 5SL3016-7, miniature circuit breaker, 1P+N, 16 A, C characteristic, 4.5 kA per IEC/EN 60898-1, DIN rail, 18 mm width.","salesMarkdown":"It interrupts faults up to 4.5 kA per IEC/EN 60898-1, making it suitable for residential and infrastructure final circuits where moderate inrush currents (lighting, small motors) are expected. Mounting position is unrestricted, so it fits in vertical or horizontal panel layouts. The neutral pole is switched (1P+N), and the supply cord can enter from any direction. Terminals accept conductors up to the listed cross-section; the unit is sealable for anti-tamper applications. IP20 rating applies with connected conductors. Rated current is 16 A at 30 °C. At elevated panel temperatures the breaker derates: 15.04 A at 40 °C, 14.53 A at 45 °C, 14 A at 50 °C, 13.46 A at 55 °C, and 12.89 A at 60 °C. For a panel running at 50 °C, plan for a 14 A continuous load per pole.","metaTitle":"Siemens 5SL3016-7 SENTRON MCB, 1P+N, 16 A, C-Curve, 4.5 kA","metaDescription":"Siemens 5SL3016-7 SENTRON miniature circuit breaker, 1P+N, 16 A, C characteristic, 4.5 kA per IEC/EN 60898-1. DIN rail mount, 18 mm wide. Active production. Quoted to order.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":["1-Pole MCB (DIN Rail)"],"specifications":{"Depth":"76 mm","Width":"18 mm","title":"5SL3016-7","Height":"90 mm","Maximum":"75 °C","Minimum":"-40 °C","Sealable":"Yes","Standard":"IEC/EN60898-1, GB/T10963.1","description":"CIRCUIT BREAKER 230V 4.5KA, 1+N-POLE/1MW C16","Halogen-Free":"Yes","Silicon-Free":"Yes","Design Of Pole":"1P+N","lifecycle_stage":"current","Fastening Method":"DIN rail","Mounting Position":"any","at AC rated value":"16 A","at DC rated value":"60 V","Installation Depth":"70 mm","Product Brand Name":"SENTRON","Degree Of Pollution":"2","Product Designation":"Miniature circuit breaker","protection class IP":"IP20, with connected conductors","Overvoltage Category":"III","Combined Terminal Top":"No","Design Of The Product":"Miniature circuit breaker compact","at 30 °C rated value":"16 A","at 40 °C rated value":"15.04 A","at 45 °C rated value":"14.53 A","at 50 °C rated value":"14 A","at 55 °C rated value":"13.46 A","at 60 °C rated value":"12.89 A","Energy Limitation Class":"3","Combined Terminal Bottom":"No","Suitability For Operation":"Residential buildings/infrastructure","Neutral Conductor Switching":"Yes","Number Of Modular Width Units":"1","Position Of Power Supply Cord":"Any","Tripping Characteristic Class":"C","according to EN 60898 rated value":"4.5 kA","Ambient Temperature During Operation":"-25...45°C: max. 85%rF, 45 60°C: max. 43%rF","Type Of Voltage Of The Operating Voltage":"AC","insulation voltage (Ui) at AC rated value":"250 V","with single-phase operation at AC maximum":"250 V","Value Range Of The Supply Voltage Frequency":"50/60 Hz","vibration resistance according to IEC 60068-2-6":"Yes","Mechanical Service Life (Operating Cycles) Typical":"10 000","Product Extension Installable Supplementary Devices":"Yes","power loss [W] for rated value of the current at AC in hot operating state per pole":"2.1 W"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"stockQuantity":0,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/fa7a13b106b09644bd9ac0b92a385ea2.pdf","sourceUrl":"https://support.industry.siemens.com/webbackend/api/ProductSupport/TechnicalData?language=en&region=cn&productId=1354190&mlfb=5SL3016-7"},"ai":{"faq":[{"question":"Who supplies 5SL3016-7 and how is it quoted?","answer":"We source this part through the authorized Siemens distribution channel. Availability and current pricing are confirmed at quote time against an RFQ — no stock figures are published here."},{"question":"What is the breaking capacity of 5SL3016-7?","answer":"The breaking capacity is 4.5 kA per IEC/EN 60898-1, which covers most residential and light commercial final circuits."},{"question":"What is the width of 5SL3016-7?","answer":"The width is 18 mm, which is one modular unit on a standard DIN rail."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"icboms-matrix-langgraph","citationUrl":"https://aoctrl.com/siemens/5SL3016-7","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/siemens/5SL3016-7 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-08-11T15:51:03.652Z","lastPublished":"2026-08-11T15:51:03.652Z","indexable":true}}