{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"5SL3216-6","brand":"Siemens","brandSlug":"siemens","productSlug":"5SL3216-6","canonicalUrl":"https://aoctrl.com/siemens/5SL3216-6","factsUrl":"https://aoctrl.com/api/mcp/products/5SL3216-6","rawCanonicalId":null},"summary":{"shortDescription":"Siemens SENTRON 5SL3216-6, miniature circuit breaker, 2-pole, B-curve, 16 A at 30 °C, 400 V AC, 4.5 kA per EN 60898, 5 kA per IEC 60947-2, IP20, 2 MWU.","salesMarkdown":"## Siemens 5SL3216-6 — SENTRON 2-Pole B-Curve MCB, 16 A, 4.5 kA The Siemens 5SL3216-6 is a SENTRON miniature circuit breaker (MCB) in a 2-pole configuration with a B-curve tripping characteristic, rated 16 A at 30 °C and 400 V AC. Rated breaking capacity is 4.5 kA per EN 60898 and 5 kA per IEC 60947-2, which covers most domestic and light commercial fault levels; for higher prospective short-circuit currents (e.g., industrial main panels), a higher-rated MCB or MCCB upstream would be needed. At 40 °C the continuous current derates to 15.23 A; at 45 °C to 14.88 A; at 55 °C to 13.99 A. This derating curve is per the manufacturer's specification and must be applied when the breaker is installed in a warm enclosure or alongside other heat-generating devices. For audit purposes, the thermal derating figures are directly from the datasheet and should be included in any panel thermal calculation. The 5SL3216-6 occupies 2 modular width units (MWU) on a DIN rail, with a width of 36 mm, depth of 76 mm, and height of 90 mm. Installation depth is 70 mm. The breaker is sealable and halogen-free and silicon-free, which is relevant for environments sensitive to outgassing (e.g., clean rooms or certain industrial processes). ## Electrical ratings and compliance The DC rating is 72 V maximum, which limits its use in DC circuits to low-voltage control applications. The energy limitation class is 3, indicating the breaker limits let-through energy to a defined level for coordination with downstream devices.","metaTitle":"Siemens 5SL3216-6 SENTRON MCB, 2-Pole B-Curve 16A 400V","metaDescription":"Siemens 5SL3216-6 SENTRON miniature circuit breaker, 2-pole, B-curve, 16 A at 30 °C, 400 V AC, 4.5 kA (EN 60898). Current production. Quoted to order.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":null,"categoryPath":[],"specifications":{"Depth":"76 mm","Poles":"2","Width":"36 mm","Height":"90 mm","IP Rating":"IP20","Product Status":"Active","Energy Limitation Class":"3"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/d38be999fe4ecd6db8c4411f49345496.pdf","sourceUrl":"https://support.industry.siemens.com/webbackend/api/ProductSupport/TechnicalData?language=en&region=cn&productId=121513&mlfb=5SL3216-6","alternativesUrl":"https://aoctrl.com/api/mcp/products/5SL3216-6/alternatives.json"},"ai":{"faq":[],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/siemens/5SL3216-6","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/siemens/5SL3216-6 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}