{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"5SL3610-7MB","brand":"Siemens","brandSlug":"siemens","productSlug":"5SL3610-7MB","canonicalUrl":"https://aoctrl.com/siemens/5SL3610-7MB","factsUrl":"https://aoctrl.com/api/mcp/products/5SL3610-7MB","rawCanonicalId":null},"summary":{"shortDescription":"Siemens SENTRON miniature circuit breaker, 5SL3610-7MB, 4-pole (3P+N), C-curve, 10 A rated current, 4.5 kA breaking capacity at 400 V AC, IP20.","salesMarkdown":"The Siemens SENTRON 5SL3610-7MB is a 4-pole miniature circuit breaker (3P+N) with a C-tripping characteristic, rated at 10 A and a breaking capacity of 4.5 kA per EN 60898 and IEC 60947-2. It's designed for residential and infrastructure panels where the C-curve handles moderate inrush from lighting or small motor loads without nuisance tripping. The 10 A rating at 30 °C is the continuous current the breaker carries in a 30 °C ambient; at 40 °C it derates to 9.3 A, and at 45 °C to 9 A (–). The C-curve means the magnetic trip fires at 5 to 10 times rated current — so for a 10 A breaker, instantaneous trip occurs between 50 A and 100 A. That's a good match for circuits with transformer inrush or motor starting, but if you're protecting electronics or long cable runs, a B-curve would trip faster on lower faults. Rated voltage is 400 V AC for multi-phase operation, with a maximum of 440 V AC. The DC rating tops out at 72 V — so this is an AC breaker; don't use it on a DC bus above 72 V without verifying the manufacturer's DC derating. Mechanical service life is 20,000 operating cycles typical. The neutral conductor is switched internally, so you land the incoming 3-phase plus neutral on the top terminals and the outgoing circuit on the bottom. Touch protection is built in.","metaTitle":"Siemens SENTRON 5SL3610-7MB MCB, 4P C-curve 10A, 4.5kA","metaDescription":"Siemens SENTRON 5SL3610-7MB miniature circuit breaker, 4-pole (3P+N), C-curve, 10 A, 4.5 kA breaking capacity at 400 V AC. Active production, available to order.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":["4-Pole MCB (DIN Rail)"],"specifications":{"Depth":"76 mm","Width":"72 mm","title":"5SL3610-7MB","Height":"90 mm","Maximum":"75 °C","Minimum":"-40 °C","Sealable":"Yes","description":"Miniature circuit breaker 400 V 4.5 kA, 3+N-pole, C, 10 A","Halogen-Free":"Yes","Silicon-Free":"Yes","Number Of Poles":"4","Type Of Voltage":"AC","lifecycle_stage":"current","Mounting Position":"any","Installation Depth":"70 mm","Product Brand Name":"SENTRON","Degree Of Pollution":"2","Product Designation":"Miniature circuit breaker","acc. to IEC 81346-2":"F","at AC / rated value":"10 A","protection class IP":"IP20, with connected conductors","Overvoltage Category":"III","Number Of Poles / Note":"3P+N","acc. to DIN EN 61346-2":"F","Energy Limitation Class":"3","at 30 °C / rated value":"10 A","at 40 °C / rated value":"9.3 A","at 45 °C / rated value":"9 A","Suitability For Operation":"Residential buildings/infrastructure","Number Of Modular Width Units":"4","Tripping Characteristic Class":"C","at DC / rated value / maximum":"72 V","acc. to EN 60898 / rated value":"4.5 kA","acc. to IEC 60947-2 / rated value":"4.5 kA","Product Feature / Touch Protection":"Yes","supply voltage / at AC / rated value":"400 V","with multi-phase operation / at AC / maximum":"440 V","Product Function / Neutral Conductor Switching":"Yes","with multi-phase operation / at AC / rated value":"440 V","Mechanical Service Life (Operating Cycles) / Typical":"20 000"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"stockQuantity":0,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/87ca44e5e32c99f8a1b9d1e53db38aec.pdf","sourceUrl":"https://support.industry.siemens.com/webbackend/api/ProductSupport/TechnicalData?language=en&region=cn&productId=435018&mlfb=5SL3610-7MB"},"ai":{"faq":[{"question":"Will 5SL3610-7MB drop into a panel specified around 5SL4363-7?","answer":"Both are 4-pole C-curve MCBs from the SENTRON family, but the 5SL4363-7 has different ratings — verify the voltage, current, and breaking capacity match your panel design before substituting."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"icboms-matrix-langgraph","citationUrl":"https://aoctrl.com/siemens/5SL3610-7MB","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/siemens/5SL3610-7MB when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-08-11T15:51:03.652Z","lastPublished":"2026-08-11T15:51:03.652Z","indexable":true}}