{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"5SL4104-7CC","brand":"Siemens","brandSlug":"siemens","productSlug":"5SL4104-7CC","canonicalUrl":"https://aoctrl.com/siemens/5SL4104-7CC","factsUrl":"https://aoctrl.com/api/mcp/products/5SL4104-7CC","rawCanonicalId":null},"summary":{"shortDescription":"Siemens SENTRON 5SL4104-7CC, miniature circuit breaker, 1-pole, C characteristic, 4 A rated current, 10 kA breaking capacity per EN 60898, 400 V AC, 1 MW unit.","salesMarkdown":"## Siemens SENTRON 5SL4104-7CC — 1-pole C-curve MCB, 4 A, 10 kA The Siemens SENTRON 5SL4104-7CC is a 1-pole miniature circuit breaker with a C tripping characteristic, rated at 4 A and 400 V AC. Its 10 kA breaking capacity per EN 60898 means it safely interrupts short-circuit faults up to that level in residential and infrastructure final circuits — think lighting, socket outlets, or small appliance feeds where the prospective fault current stays under 10 kA. ## What the ratings mean for fit The C-curve (5–10× In) is the standard choice for moderate inrush loads — small motors, transformers, capacitive LED drivers — where a B-curve would nuisance-trip on startup but a D-curve isn't needed. At 4 A it covers a 900 W resistive load at 230 V or a small pump/ventilation fan. The 1-pole form factor (18 mm width, one modular unit) snaps onto a standard DIN rail; the 76 mm depth and 70 mm installation depth leave clearance for a standard distribution board enclosure. Rated for overvoltage category III and pollution degree 2, this MCB is at home in fixed-installation distribution boards where the upstream transformer and service entrance are within the same building. The IP20 rating (with connected conductors) is typical for enclosed panel use — no washdown or outdoor exposure. ## Panel integration notes Mounts in any position on a standard DIN rail. The 18 mm width occupies exactly one modular unit — useful when packing a dense distribution board. Sealable design (tamper-evident cover available) for installations that require lockout. Halogen-free and silicon-free construction matters if the panel is in a clean room or a corrosive environment where outgassing could contaminate contacts. Supplementary devices (auxiliary switches, shunt trips, alarm contacts) can be added on the right side — the product extension flag is set to Yes, so the accessory range for SENTRON 5SL series fits without modification.","metaTitle":"Siemens 5SL4104-7CC SENTRON MCB, 1P C-curve 4A 10kA","metaDescription":"Siemens SENTRON 5SL4104-7CC miniature circuit breaker, 1-pole, C characteristic, 4 A, 10 kA per EN 60898, 400 V AC. Active production, sourced to order.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":[],"specifications":{"Depth":"76 mm","Poles":"1","Width":"18 mm","Height":"90 mm","IP Rating":"IP20","Product Status":"Active","Energy Limitation Class":"3"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/b740b0085421af97c0af69348f11467c.pdf","sourceUrl":"https://support.industry.siemens.com/webbackend/api/ProductSupport/TechnicalData?language=en&region=cn&productId=207582&mlfb=5SL4104-7CC","alternativesUrl":"https://aoctrl.com/api/mcp/products/5SL4104-7CC/alternatives.json"},"ai":{"faq":[],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/siemens/5SL4104-7CC","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/siemens/5SL4104-7CC when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}