{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"5SL4108-8CC","brand":"Siemens","brandSlug":"siemens","productSlug":"5SL4108-8CC","canonicalUrl":"https://aoctrl.com/siemens/5SL4108-8CC","factsUrl":"https://aoctrl.com/api/mcp/products/5SL4108-8CC","rawCanonicalId":null},"summary":{"shortDescription":"Siemens SENTRON 5SL4108-8CC miniature circuit breaker, 1-pole, D tripping characteristic, 8 A rated current, 10 kA breaking capacity per EN 60898, 230/400 V AC.","salesMarkdown":"## Siemens 5SL4108-8CC SENTRON MCB — 1-pole D-curve 8 A The Siemens 5SL4108-8CC is a 1-pole miniature circuit breaker from the SENTRON series, with a D tripping characteristic rated at 8 A. It breaks fault currents up to 10 kA per EN 60898 at 230/400 V AC — the standard residential and light commercial interrupting rating. The D-curve means it tolerates the high inrush of motor and transformer loads without nuisance tripping, making it a fit for pump, compressor, or small-drive branch circuits where a C-curve would trip on startup. ## What the ratings mean for your panel Rated 8 A continuous, with a D-curve magnetic trip that holds through the 5–10× In surge typical of motor starts. The 10 kA breaking capacity per EN 60898 certifies it can safely interrupt a 10 kA prospective short-circuit current at 230/400 V — that is the standard for most residential and light commercial distribution boards. Single-pole design (1P) means it switches only the phase; the neutral is not broken. Rated for single-phase operation at 250 V AC and multi-phase at 440 V AC, so it covers both 230 V branch circuits and 400 V three-phase panels when used on one phase. The 18 mm width (1 modular unit) snaps onto standard DIN rail and occupies one slot in a distribution board. Depth of 76 mm and height of 90 mm keep it flush with adjacent devices. Mounting position is unrestricted — any orientation works. The IP20 rating (with connected conductors) is typical for enclosed panel use; no washdown or outdoor exposure without an outer enclosure. Rated for ambient temperatures from -40 °C to 75 °C, covering unheated enclosures in cold climates and warm cabinets near transformers. The 0.8 W power loss per pole at rated current is low enough to ignore for thermal budgeting in a populated board. Supplementary devices (auxiliary contacts, shunt trips, alarm switches) can be snapped onto the right side — the product extension feature is supported.","metaTitle":"Siemens 5SL4108-8CC SENTRON MCB, 1P D 8A 10kA","metaDescription":"Siemens 5SL4108-8CC SENTRON miniature circuit breaker, 1-pole, D-curve, 8A, 10kA breaking capacity per EN 60898. Active production. Quoted to order.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":[],"specifications":{"Depth":"76 mm","Poles":"1","Width":"18 mm","Height":"90 mm","IP Rating":"IP20","Product Status":"Active"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/b740b0085421af97c0af69348f11467c.pdf","sourceUrl":"https://support.industry.siemens.com/webbackend/api/ProductSupport/TechnicalData?language=en&region=cn&productId=49491&mlfb=5SL4108-8CC","alternativesUrl":"https://aoctrl.com/api/mcp/products/5SL4108-8CC/alternatives.json"},"ai":{"faq":[],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/siemens/5SL4108-8CC","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/siemens/5SL4108-8CC when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}