{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"5SL4110-7CC","brand":"Siemens","brandSlug":"siemens","productSlug":"5SL4110-7CC","canonicalUrl":"https://aoctrl.com/siemens/5SL4110-7CC","factsUrl":"https://aoctrl.com/api/mcp/products/5SL4110-7CC","rawCanonicalId":null},"summary":{"shortDescription":"Siemens SENTRON miniature circuit breaker, 5SL4110-7CC, 1-pole, C-curve, 10 A, 10 kA breaking capacity per EN 60898, 400 V AC, 1 MWU.","salesMarkdown":"The Siemens SENTRON 5SL4110-7CC is a 1-pole miniature circuit breaker with a C tripping characteristic, rated 10 A and a breaking capacity of 10 kA according to EN 60898 at 400 V AC. Rated for single-phase operation up to 250 V AC and multi-phase up to 440 V AC, it handles both 230/400 V split-phase and 400 V three-phase networks. The supply frequency is 50/60 Hz, covering both mains standards globally. For DC circuits, the maximum rated voltage is 72 V — useful for control circuits but not for high-voltage DC bus protection. Depth is 76 mm, height 90 mm, width 18 mm (1 MWU). The terminals accept supplementary devices (shunt trip, auxiliary contacts, alarm switch) for remote signaling or emergency off. The 5SL4363-7 is the 3-pole version of the same breaker family — same depth (76 mm), height (90 mm), C-curve, 10 kA breaking capacity per both EN 60898 and IEC 60947-2, and same 400 V AC rating. The key difference: the 3-pole unit occupies 3 MWU (54 mm wide) and dissipates 5 W per pole in hot state. If your panel was laid out for 5SL4363-7, the 1-pole 5SL4110-7CC will not drop in without rewiring — the pole count and busbar arrangement are different. But within a single-phase branch circuit, the 5SL4110-7CC is the correct 1-pole choice.","metaTitle":"Siemens SENTRON 5SL4110-7CC MCB, 1P C 10A 10kA","metaDescription":"Siemens SENTRON 5SL4110-7CC miniature circuit breaker, 1-pole, C-curve, 10 A, 10 kA per EN 60898, 400 V AC. Active production. Quoted to order.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":["1-Pole MCB (DIN Rail)"],"specifications":{"Depth":"76 mm","Width":"18 mm","title":"5SL4110-7CC","Height":"90 mm","Maximum":"75 °C","Minimum":"-40 °C","Sealable":"Yes","description":"Miniature circuit breaker 230/400 V 10kA, 1-pole, C, 10 A Circuit breaker 230/400 V 10kA, 1-pole, C, 10 A","Halogen-Free":"Yes","Silicon-Free":"Yes","Design Of Pole":"1P","Number Of Poles":"1","lifecycle_stage":"current","Mounting Position":"any","Installation Depth":"70 mm","Product Brand Name":"SENTRON","Degree Of Pollution":"2","Product Designation":"Miniature circuit breaker","protection class IP":"IP20, with connected conductors","Overvoltage Category":"III","Energy Limitation Class":"3","Suitability For Operation":"Residential buildings/infrastructure","at DC rated value maximum":"72 V","Number Of Modular Width Units":"1","Tripping Characteristic Class":"C","supply voltage at AC rated value":"400 V","according to EN 60898 rated value":"10 kA","Type Of Voltage Of The Operating Voltage":"AC","with multi-phase operation at AC maximum":"440 V","Value Range Of The Supply Voltage Frequency":"50/60 Hz","with multi-phase operation at AC rated value":"440 V","with single-phase operation at AC rated value":"250 V","vibration resistance according to IEC 60068-2-6":"50 m/s² at 25 to 150 Hz","Product Extension Installable Supplementary Devices":"Yes","power loss [W] for rated value of the current at AC in hot operating state per pole":"0.9 W"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"stockQuantity":0,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/d4bebc237fa092287aaa2ed9f79819e0.pdf","sourceUrl":"https://support.industry.siemens.com/webbackend/api/ProductSupport/TechnicalData?language=en&region=cn&productId=15804&mlfb=5SL4110-7CC"},"ai":{"faq":[{"question":"Where can I buy 5SL4110-7CC and get a price?","answer":"The 5SL4110-7CC is sourced and quoted to order through independent distribution. Submit an RFQ for current availability and pricing — confirmed at quote time."},{"question":"What is the breaking capacity of 5SL4110-7CC?","answer":"The breaking capacity is 10 kA according to EN 60898 at 400 V AC. This means it safely interrupts fault currents up to 10,000 A without welding or cascading failure."},{"question":"What is the width and depth of 5SL4110-7CC?","answer":"Width is 18 mm (1 modular width unit), depth is 76 mm, height is 90 mm. Installation depth is 70 mm. It snaps onto standard 35 mm DIN rail."},{"question":"Will 5SL4110-7CC drop into a panel specified for 5SL4363-7?","answer":"No — the 5SL4363-7 is a 3-pole breaker (54 mm wide) while the 5SL4110-7CC is 1-pole (18 mm wide). The pole count and busbar arrangement differ; rewiring would be required."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"icboms-matrix-langgraph","citationUrl":"https://aoctrl.com/siemens/5SL4110-7CC","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/siemens/5SL4110-7CC when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-08-11T15:51:03.652Z","lastPublished":"2026-08-11T15:51:03.652Z","indexable":true}}