{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"5SL4110-8CC","brand":"Siemens","brandSlug":"siemens","productSlug":"5SL4110-8CC","canonicalUrl":"https://aoctrl.com/siemens/5SL4110-8CC","factsUrl":"https://aoctrl.com/api/mcp/products/5SL4110-8CC","rawCanonicalId":null},"summary":{"shortDescription":"Siemens SENTRON 5SL4110-8CC, 1-pole miniature circuit breaker, D-curve, 10 A, 10 kA interrupting capacity per EN 60898, 400 V AC.","salesMarkdown":"## 1-pole D-curve MCB for high-inrush loads The Siemens SENTRON 5SL4110-8CC is a 1-pole miniature circuit breaker with a D tripping characteristic, rated 10 A at 400 V AC and interrupting 10 kA per EN 60898. The D-curve means it tolerates the high inrush currents typical of motor starters, small transformers, and solenoid valve banks — the magnetic trip threshold is 10 to 20 times the rated current, so nuisance tripping on startup is rare. It occupies a single 18 mm modular width unit on the DIN rail, leaving room in the panel for other branch circuits. ## Ratings that decide the fit Breaking capacity is 10 kA at 400 V AC per EN 60898 — this is the standard for residential and light commercial distribution boards. The breaker is rated for single-phase operation up to 250 V AC and multi-phase up to 440 V AC. Power loss per pole is 0.9 W in hot operating state; in a densely packed enclosure, that low dissipation keeps the internal temperature rise manageable. The operating temperature range spans -40 °C to 75 °C, which covers unheated utility rooms and outdoor-adjacent cabinets. Vibration resistance is 50 m/s² over 25 to 150 Hz per IEC 60068-2-6, adequate for installation near light industrial machinery. ## Panel integration notes Mounts on standard 35 mm DIN rail in any position. Depth is 76 mm, installation depth 70 mm, so it fits flush in a 100 mm deep enclosure with room for wiring behind the busbar. The IP20 rating with connected conductors means the terminals are finger-safe once the circuit is wired — standard for distribution boards. Supplementary devices (auxiliary switches, shunt trips, alarm contacts) can be snapped onto the right side without additional DIN space. The housing is halogen-free and silicon-free, which matters for panels in clean rooms or areas with sensitive electronics.","metaTitle":"Siemens 5SL4110-8CC SENTRON MCB, 1P D 10 A 10 kA","metaDescription":"Siemens 5SL4110-8CC SENTRON miniature circuit breaker, 1-pole, D-curve, 10 A, 10 kA per EN 60898, 400 V AC. Active production, sourced to order. Request a quote.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":[],"specifications":{"Depth":"76 mm","Poles":"1","Width":"18 mm","Height":"90 mm","IP Rating":"IP20","Product Status":"Active"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/d4bebc237fa092287aaa2ed9f79819e0.pdf","sourceUrl":"https://support.industry.siemens.com/webbackend/api/ProductSupport/TechnicalData?language=en&region=cn&productId=408861&mlfb=5SL4110-8CC","alternativesUrl":"https://aoctrl.com/api/mcp/products/5SL4110-8CC/alternatives.json"},"ai":{"faq":[],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/siemens/5SL4110-8CC","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/siemens/5SL4110-8CC when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}