{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"5SL4113-7RC","brand":"Siemens","brandSlug":"siemens","productSlug":"5SL4113-7RC","canonicalUrl":"https://aoctrl.com/siemens/5SL4113-7RC","factsUrl":"https://aoctrl.com/api/mcp/products/5SL4113-7RC","rawCanonicalId":null},"summary":{"shortDescription":"Siemens SENTRON 5SL4 series miniature circuit breaker, 5SL4113-7RC, 1-pole, C-curve, 13 A, 10 kA breaking capacity per EN 60898, 240/415 V AC.","salesMarkdown":"The Siemens SENTRON 5SL4113-7RC is a 1-pole miniature circuit breaker (MCB) from the 5SL4 design family, rated 13 A with a C tripping characteristic and a 10 kA breaking capacity per EN 60898. It operates on AC supplies at 240/415 V, covering single-phase line-to-neutral (250 V) and multi-phase line-to-line (440 V) applications. The C-curve means it trips between 5 and 10 times rated current — standard for general-purpose protection of resistive and moderate inductive loads in residential and infrastructure panels. ## What the ratings mean for fit The 10 kA breaking capacity (per EN 60898) is the maximum prospective fault current this MCB can safely interrupt at its rated voltage — sufficient for most residential and light commercial service entrances where the available fault current stays under that threshold. The 13 A rating and C-curve make it a direct fit for 13 A ring-main or radial circuits in UK/EU-style distribution boards, protecting socket outlets and fixed appliances with moderate inrush (e.g., small pumps, refrigeration compressors). At 18 mm wide (1 width unit), it occupies a single module on a standard DIN rail — essential for high-density panels where every slot counts. The 76 mm depth and 70 mm installation depth mean it fits flush in most domestic consumer units and small distribution boards without protruding past the enclosure door. IP20 with connected conductors is the norm for enclosed panel mounting; no special sealing required. Rated for ambient temperatures from -40 °C to +75 °C, so it handles unheated utility rooms, outdoor enclosures in cold climates, and high-heat conditions near transformer vaults. The halogen-free and silicon-free construction matters for installations in hospitals, data centers, or other environments where corrosive off-gassing during a fault must be minimized. ## Integration notes Snap-on mounting to 35 mm DIN rail per EN 60715; any mounting position accepted. The sealable design (lockable toggle) allows the facility manager to lock the breaker in the ON or OFF position for lockout/tagout compliance without additional hardware. Neutral conductor switching is not built in — this is a single-pole device switching only the phase; the neutral bus bar runs uninterrupted. Overvoltage category III and pollution degree 2 ratings confirm it is suitable for fixed-installation distribution boards where transient overvoltages (e.g., from utility switching) are expected and the environment is non-conductive but may have occasional condensation. The energy limiting class 3 (highest) means it restricts let-through energy well, protecting downstream wiring and equipment during a short circuit.","metaTitle":"5SL4113-7RC SENTRON MCB, 1P C 13A 10kA","metaDescription":"Siemens SENTRON 5SL4113-7RC miniature circuit breaker, 1-pole, C-curve, 13 A, 10 kA breaking capacity per EN 60898. Current lifecycle stage. Available to order against RFQ.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":["1-Pole MCB (DIN Rail)"],"specifications":{"Depth":"76 mm","Width":"18 mm","title":"5SL4113-7RC","Height":"90 mm","Maximum":"75 °C","Minimum":"-40 °C","Sealable":"Yes","Rated Value":"50 Hz","description":"Miniature circuit breaker 240/415 V 10kA, 1-pole, C, 13A","Halogen-Free":"Yes","Silicon-Free":"Yes","Number of poles":"1","Type of voltage":"AC","lifecycle_stage":"current","Mounting position":"any","Installation depth":"70 mm","Product brand name":"SENTRON","Degree of pollution":"2","Product designation":"Miniature circuit breaker","Protection class IP":"IP20, with connected conductors","Overvoltage category":"III","Design of the product":"5SL miniature circuit breakers","Energy limiting class":"3","Number of width units":"1","Number of poles / Note":"1P","acc. to DIN EN 61346-2":"F","acc. to DIN EN 81346-2":"F","circuit-breaker / Design":"5SL4","Suitability for operation":"Residential buildings/infrastructure","Tripping characteristic class":"C","at DC / rated value / maximum":"72 V","acc. to EN 60898 / rated value":"10 kA","Product feature / Touch protection":"Yes","Supply voltage / at AC / rated value":"415 V","Operating current / at AC / rated value":"13 A","with multi-phase operation / at AC / maximum":"440 V","Product function / neutral conductor switching":"No","with multi-phase operation / at AC / rated value":"440 V","with single-phase operation / at AC / rated value":"250 V","Mechanical service life (switching cycles) / typical":"10 000"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"stockQuantity":0,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/d4bebc237fa092287aaa2ed9f79819e0.pdf","sourceUrl":"https://support.industry.siemens.com/webbackend/api/ProductSupport/TechnicalData?language=en&region=cn&productId=276575&mlfb=5SL4113-7RC"},"ai":{"faq":[{"question":"What is the breaking capacity of 5SL4113-7RC?","answer":"The breaking capacity is 10 kA per EN 60898 at 240/415 V AC. This is the maximum fault current the MCB can safely interrupt under standard test conditions."},{"question":"Where can I buy 5SL4113-7RC and how is it quoted?","answer":"The 5SL4113-7RC is sourced and quoted to order against an RFQ through independent distribution. Availability and current pricing are confirmed at quote time — submit an RFQ for your target quantity."},{"question":"Will 5SL4113-7RC drop into a panel specified around 5SL6132-6MB without rewiring?","answer":"Both are 1-pole SENTRON MCBs on the same 18 mm DIN-rail footprint, so the mechanical fit is identical. The 5SL4113-7RC is a 13 A C-curve device; the 5SL6132-6MB is a different rating and curve — verify the circuit's load and coordination requirements before swapping. The physical swap takes seconds; the electrical decision needs a spec check."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"icboms-matrix-langgraph","citationUrl":"https://aoctrl.com/siemens/5SL4113-7RC","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/siemens/5SL4113-7RC when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-08-11T15:51:03.652Z","lastPublished":"2026-08-11T15:51:03.652Z","indexable":true}}