{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"5SL4116-8CC","brand":"Siemens","brandSlug":"siemens","productSlug":"5SL4116-8CC","canonicalUrl":"https://aoctrl.com/siemens/5SL4116-8CC","factsUrl":"https://aoctrl.com/api/mcp/products/5SL4116-8CC","rawCanonicalId":null},"summary":{"shortDescription":"Siemens SENTRON 5SL miniature circuit breaker, 5SL4116-8CC, 1-pole, D tripping characteristic, 16 A rated current, 10 kA breaking capacity at 230/400 V AC.","salesMarkdown":"## Siemens 5SL4116-8CC — D-curve MCB for high-inrush loads The Siemens 5SL4116-8CC is a 1-pole miniature circuit breaker from the SENTRON 5SL family, rated 16 A with a D tripping characteristic and a 10 kA breaking capacity per EN 60898 at 230/400 V AC. Snaps onto DIN rail in any orientation. The 18 mm width (1 width unit) means it occupies one standard module position in a distribution board or enclosure. Terminal capacity accepts 0.75 mm² to 25 mm² conductors. Touch protection is built in. The D-curve trips between 10 and 20 times the rated current (160–320 A magnetic trip), so it holds through the startup surge of a motor or transformer but clears a hard short quickly. Rated for single-phase operation at 250 V AC and multi-phase at 440 V AC, with a maximum of 60 V DC. The overvoltage category is 3 (distribution level).","metaTitle":"Siemens 5SL4116-8CC SENTRON MCB, 1P D 16A 10kA","metaDescription":"Siemens SENTRON 5SL4116-8CC miniature circuit breaker, 1-pole, D-curve, 16 A, 10 kA breaking capacity per EN 60898. Active production, sourced to order.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":["1-Pole MCB (DIN Rail)"],"specifications":{"Depth":"76 mm","Width":"18 mm","title":"5SL4116-8CC","Height":"90 mm","Maximum":"25 mm²","Minimum":"0.75 mm²","Sealable":"Yes","Rated Value":"50 Hz","description":"Miniature circuit breaker 230/400 V 10kA, 1-pole, D, 16A Circuit breaker 230/400 V 10kA, 1-pole, D, 16A","Halogen-Free":"Yes","Silicon-Free":"Yes","Number of poles":"1","Type of voltage":"AC","lifecycle_stage":"current","Mounting position":"any","Installation depth":"70 mm","Product brand name":"SENTRON","Product designation":"Miniature circuit breaker","Protection class IP":"IP20, with connected conductors","Overvoltage category":"3","Design of the product":"5SL miniature circuit breakers","Number of width units":"1","Number of poles / Note":"1P","acc. to DIN EN 61346-2":"F","acc. to DIN EN 81346-2":"F","circuit-breaker / Design":"5SL4CC","Suitability for operation":"Residential buildings/infrastructure","Current / at AC / rated value":"16 A","Tripping characteristic class":"D","at DC / rated value / maximum":"60 V","acc. to EN 60898 / rated value":"10 kA","Product feature / Touch protection":"Yes","Supply voltage / at AC / rated value":"400 V","Influence of the surrounding temperature":"+55 °C, max. 95% humidity","Vibration resistance / acc. to IEC 60068-2-6":"50 m/s² at 25 to 150 Hz","with multi-phase operation / at AC / maximum":"440 V","Product function / neutral conductor switching":"No","with multi-phase operation / at AC / rated value":"440 V","with single-phase operation / at AC / rated value":"250 V"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"stockQuantity":0,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/d4bebc237fa092287aaa2ed9f79819e0.pdf","sourceUrl":"https://support.industry.siemens.com/webbackend/api/ProductSupport/TechnicalData?language=en&region=cn&productId=253015&mlfb=5SL4116-8CC"},"ai":{"faq":[{"question":"Where can I buy 5SL4116-8CC?","answer":"This part is sourced and quoted to order against an RFQ through independent distribution channels. Current pricing and availability are confirmed at the time of quotation."},{"question":"What is the breaking capacity of 5SL4116-8CC?","answer":"The 5SL4116-8CC has a 10 kA breaking capacity per EN 60898 at 230/400 V AC."},{"question":"What does the D-curve mean on this breaker?","answer":"The D tripping characteristic (10–20× In) is designed for loads with high inrush currents such as motors, transformers, and discharge lighting, preventing nuisance tripping on startup while still clearing short circuits quickly."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"icboms-matrix-langgraph","citationUrl":"https://aoctrl.com/siemens/5SL4116-8CC","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/siemens/5SL4116-8CC when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-08-11T15:51:03.652Z","lastPublished":"2026-08-11T15:51:03.652Z","indexable":true}}