{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"5SL4202-6CC","brand":"Siemens","brandSlug":"siemens","productSlug":"5SL4202-6CC","canonicalUrl":"https://aoctrl.com/siemens/5SL4202-6CC","factsUrl":"https://aoctrl.com/api/mcp/products/5SL4202-6CC","rawCanonicalId":null},"summary":{"shortDescription":"Siemens SENTRON 5SL4202-6CC miniature circuit breaker, 2-pole, B characteristic, 2 A, 400 V AC, 10 kA breaking capacity per EN 60898.","salesMarkdown":"## What this 2 A B-curve MCB is for The Siemens 5SL4202-6CC is a 2-pole SENTRON miniature circuit breaker rated 2 A at 400 V AC with a B tripping characteristic and 10 kA breaking capacity per EN 60898. It protects branch circuits in residential and infrastructure panels — think lighting, general-purpose outlets, and small resistive loads where the B-curve's magnetic trip at 3–5× rated current keeps nuisance trips off sensitive electronics. The 2 A rating governs the continuous load the breaker can carry — size it for a circuit that draws under 1.6 A continuous to stay within the 80 % derating rule for continuous loads per NEC. The B-curve trips magnetically between 3× and 5× rated current (6–10 A), so it's a good match for resistive loads and short cable runs where inrush stays low; don't use it on motor circuits or transformers that see a higher starting surge — that's C- or D-curve territory. The 2-pole construction switches both phase and neutral on a single-phase circuit, or two phases on a split-phase system. Note that neutral conductor switching is not provided — this breaker does not include a switched neutral pole, so the neutral path is solid through the device. Overvoltage category 3 and pollution degree 2 confirm it's rated for fixed-installation panels where transient overvoltages and normal indoor contamination are expected. Physical fit: 36 mm width — that's 2 width units at 18 mm per pole — and 76 mm depth with 70 mm installation depth. Height is 90 mm. Vibration resistance tested to 50 m/s² over 25–150 Hz per IEC 60068-2-6 — solid for transport and moderate machine vibration. The breaker is sealable — a lead seal can be passed through the housing to prevent tampering after commissioning, useful for metered or rental subpanels.","metaTitle":"Siemens 5SL4202-6CC SENTRON MCB, 2-pole B-curve 2A 10kA","metaDescription":"Siemens 5SL4202-6CC SENTRON miniature circuit breaker, 2-pole, B characteristic, 2A rated current, 10kA breaking capacity at 400V AC. Current lifecycle stage, available to order. S","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":[],"specifications":{"Depth":"76 mm","Poles":"2","Width":"36 mm","Height":"90 mm","IP Rating":"IP20","Product Status":"Active"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/7404ae85aaaa1f58b9c29459ca8938a8.pdf","sourceUrl":"https://support.industry.siemens.com/webbackend/api/ProductSupport/TechnicalData?language=en&region=cn&productId=145416&mlfb=5SL4202-6CC","alternativesUrl":"https://aoctrl.com/api/mcp/products/5SL4202-6CC/alternatives.json"},"ai":{"faq":[],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/siemens/5SL4202-6CC","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/siemens/5SL4202-6CC when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}