{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"5SL4216-7CC","brand":"Siemens","brandSlug":"siemens","productSlug":"5SL4216-7CC","canonicalUrl":"https://aoctrl.com/siemens/5SL4216-7CC","factsUrl":"https://aoctrl.com/api/mcp/products/5SL4216-7CC","rawCanonicalId":null},"summary":{"shortDescription":"Siemens SENTRON 5SL miniature circuit breaker, 2-pole, C-curve, 16 A, 400 V AC, 10 kA breaking capacity per EN 60898, 2 modular width units.","salesMarkdown":"## What this MCB does in the panel The Siemens 5SL4216-7CC is a SENTRON miniature circuit breaker rated 16 A at 400 V AC with a 10 kA breaking capacity per EN 60898. Two-pole switching isolates both phase conductors in a single-width 2-module footprint (36 mm wide). For a 16 A circuit feeding lighting or receptacle loads in a residential or light-commercial panel, that is the standard headroom. The C-curve means the magnetic trip activates at 80–160 A (5–10× In), which avoids tripping on the inrush of a few fluorescent fixtures or a small motor. Temperature range covers -40 to 75 °C, so the breaker can live in an unheated enclosure or a hot switchroom. The 50 Hz rating is the standard mains frequency; the 440 V maximum for multi-phase operation confirms it can be used on 400 V three-phase systems where line-to-line voltage is 400 V. Snap-on DIN rail mount, any orientation. Two modular width units (36 mm) — matches the standard 18 mm per pole spacing. Touch protection is built in; sealable option is available for tamper-proofing in metered or public-access panels.","metaTitle":"Siemens 5SL4216-7CC SENTRON MCB, 2-Pole C 16A 400V 10kA","metaDescription":"Siemens 5SL4216-7CC SENTRON miniature circuit breaker, 2-pole, C-curve, 16 A, 400 V AC, 10 kA breaking capacity per EN 60898. Current lifecycle stage, sourced to order.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":["2-Pole MCB (DIN Rail)"],"specifications":{"Depth":"76 mm","Width":"36 mm","title":"5SL4216-7CC","Height":"90 mm","Maximum":"75 °C","Minimum":"-40 °C","Sealable":"Yes","Rated Value":"50 Hz","description":"Miniature circuit breaker 400 V 10kA, 2-pole, C, 16A Circuit breaker 400 V 10kA, 2-pole, C, 16A","Halogen-Free":"Yes","Silicon-Free":"Yes","Number Of Poles":"2","Type Of Voltage":"AC","lifecycle_stage":"current","Mounting Position":"any","Installation Depth":"70 mm","Product Brand Name":"SENTRON","Degree Of Pollution":"2","Product Designation":"Miniature circuit breaker","acc. to IEC 81346-2":"F","protection class IP":"IP20, with connected conductors","Overvoltage Category":"III","Design Of The Product":"5SL miniature circuit breakers","Number Of Poles / Note":"2P","acc. to DIN EN 61346-2":"F","Energy Limitation Class":"3","Suitability For Operation":"Residential buildings/infrastructure","Number Of Modular Width Units":"2","Tripping Characteristic Class":"C","at DC / rated value / maximum":"72 V","acc. to EN 60898 / rated value":"10 kA","Product Feature / Touch Protection":"Yes","supply voltage / at AC / rated value":"400 V","Influence Of The Surrounding Temperature":"+55 °C, max. 95% humidity","operational current / at AC / rated value":"16 A","vibration resistance / acc. to IEC 60068-2-6":"50 m/s² at 25 to 150 Hz","with multi-phase operation / at AC / maximum":"440 V","operational current / at 30 °C / rated value":"16 A","Product Function / Neutral Conductor Switching":"No","with multi-phase operation / at AC / rated value":"440 V"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"stockQuantity":0,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/f4ab5c3772864a9cd57ddebfe9666c12.pdf","sourceUrl":"https://support.industry.siemens.com/webbackend/api/ProductSupport/TechnicalData?language=en&region=cn&productId=15809&mlfb=5SL4216-7CC"},"ai":{"faq":[{"question":"Where can I buy the 5SL4216-7CC and get current pricing?","answer":"This part is sourced and quoted to order against an RFQ through independent distribution. Availability and current pricing are confirmed at the time of quotation."},{"question":"What is the breaking capacity of the 5SL4216-7CC?","answer":"10 kA per EN 60898 at 400 V AC, which is the standard rating for this class of miniature circuit breaker in residential and light-commercial distribution boards."},{"question":"Will the 5SL4216-7CC drop into a panel specified around the 5SL3232-6MB?","answer":"Both are 2-pole SENTRON 5SL-series MCBs on the same DIN-rail footprint, so the mechanical fit is identical. The difference is rating: the 5SL4216-7CC is a 16 A C-curve at 400 V, while the 5SL3232-6MB is a different current/curve combination. Verify the load requirements before swapping."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"icboms-matrix-langgraph","citationUrl":"https://aoctrl.com/siemens/5SL4216-7CC","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/siemens/5SL4216-7CC when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-08-11T15:51:03.652Z","lastPublished":"2026-08-11T15:51:03.652Z","indexable":true}}