{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"5SL4410-6","brand":"Siemens","brandSlug":"siemens","productSlug":"5SL4410-6","canonicalUrl":"https://aoctrl.com/siemens/5SL4410-6","factsUrl":"https://aoctrl.com/api/mcp/products/5SL4410-6","rawCanonicalId":null},"summary":{"shortDescription":"Siemens SENTRON 5SL4410-6 miniature circuit breaker, 4-pole, B-characteristic, 10 A rated, 10 kA breaking capacity, 400 V AC, 4 MW units.","salesMarkdown":"## Siemens 5SL4410-6 SENTRON 4P B-10A MCB The Siemens 5SL4410-6 is a 4-pole miniature circuit breaker from the SENTRON series, rated 10 A at 400 V AC with a B tripping characteristic and a 10 kA breaking capacity certified to both EN 60898 and IEC 60947-2. That 10 kA rating means it safely clears a bolted fault up to that level without upstream coordination issues in a residential or infrastructure panel — the listed suitability for residential buildings/infrastructure confirms the intended install base. The B-curve trips between 3 and 5 times rated current, so it's sized for lighting and general-purpose loads where inrush is modest, not motor starts. Mechanical life is rated at 10 000 operating cycles typical, and the unit is sealable — useful for utility or submetering applications where tamper evidence is required. The housing is halogen-free and silicon-free, which matters for installations with sensitive contacts or environmental compliance requirements. ## Mounting and integration Occupies 4 modular-width units (72 mm) on a DIN rail. Depth is 76 mm, installation depth 70 mm. Mounting position is any, so it fits vertical or horizontal panel layouts without derating. IP20 with connected conductors — standard for enclosed distribution boards; no washdown rating, so keep it inside the cabinet. Overvoltage category III and pollution degree 2, which is the typical spec for fixed-installation distribution boards downstream of the main incoming supply. ## Thermal derating and ambient limits Rated 10 A at 30 °C ambient. At 40 °C it derates to 9.24 A; at 45 °C to 8.8 A; at 55 °C to 7.96 A. If the panel ambient runs hot — say, a crowded enclosure near a furnace line — factor that derating into the load schedule. The maximum ambient is 55 °C with up to 95% humidity; storage range is -40 to 75 °C.","metaTitle":"Siemens 5SL4410-6 SENTRON MCB, 4P, B-10A, 10kA, 400V AC","metaDescription":"Siemens 5SL4410-6 SENTRON miniature circuit breaker, 4-pole, B-curve, 10 A, 10 kA breaking capacity per EN 60898 / IEC 60947-2, 400 V AC. Active production. Sourced to order.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":["4-Pole MCB (DIN Rail)"],"specifications":{"Depth":"76 mm","Width":"72 mm","title":"5SL4410-6","Height":"90 mm","Maximum":"75 °C","Minimum":"-40 °C","Sealable":"Yes","description":"Miniature circuit breaker 400 V 10kA, 4-pole, B, 10 A","Halogen-Free":"Yes","Silicon-Free":"Yes","Number Of Poles":"4","Type Of Voltage":"AC","lifecycle_stage":"current","Mounting Position":"any","Installation Depth":"70 mm","Product Brand Name":"SENTRON","Degree Of Pollution":"2","Product Designation":"Miniature circuit breaker","acc. to IEC 81346-2":"F","at AC / rated value":"10 A","protection class IP":"IP20, with connected conductors","Overvoltage Category":"III","Number Of Poles / Note":"4P","acc. to DIN EN 61346-2":"F","Energy Limitation Class":"3","at 30 °C / rated value":"10 A","at 40 °C / rated value":"9.24 A","at 45 °C / rated value":"8.8 A","at 55 °C / rated value":"7.96 A","Suitability For Operation":"Residential buildings/infrastructure","Number Of Modular Width Units":"4","Tripping Characteristic Class":"B","at DC / rated value / maximum":"72 V","acc. to EN 60898 / rated value":"10 kA","acc. to IEC 60947-2 / rated value":"10 kA","Product Feature / Touch Protection":"Yes","supply voltage / at AC / rated value":"400 V","Influence Of The Surrounding Temperature":"+55 °C, max. 95% humidity","with multi-phase operation / at AC / maximum":"440 V","Product Function / Neutral Conductor Switching":"No","with multi-phase operation / at AC / rated value":"440 V","Mechanical Service Life (Operating Cycles) / Typical":"10 000"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"stockQuantity":0,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/ad43b931801eb24b98c90e7f6e2824ba.pdf","sourceUrl":"https://support.industry.siemens.com/webbackend/api/ProductSupport/TechnicalData?language=en&region=cn&productId=27674&mlfb=5SL4410-6"},"ai":{"faq":[{"question":"Where can I buy 5SL4410-6 and how do I get a price?","answer":"This part is sourced and quoted to order against an RFQ through independent distribution. Availability and current pricing are confirmed at quote time."},{"question":"What is 5SL4410-6's listed depth (76 mm) on this component line?","answer":"The depth is 76 mm; installation depth is 70 mm."},{"question":"What is 5SL4410-6's listed width (72 mm) on this component line?","answer":"Width is 72 mm, which corresponds to 4 modular-width units on a DIN rail."},{"question":"What compliance documentation does Siemens provide for 5SL4410-6?","answer":"The MCB is certified to EN 60898 and IEC 60947-2 for breaking capacity, rated overvoltage category III, pollution degree 2, and is halogen-free and silicon-free. The product is designed for residential buildings and infrastructure per the manufacturer's suitability listing."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"icboms-matrix-langgraph","citationUrl":"https://aoctrl.com/siemens/5SL4410-6","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/siemens/5SL4410-6 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-08-11T15:51:03.652Z","lastPublished":"2026-08-11T15:51:03.652Z","indexable":true}}