{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"5SL4410-7","brand":"Siemens","brandSlug":"siemens","productSlug":"5SL4410-7","canonicalUrl":"https://aoctrl.com/siemens/5SL4410-7","factsUrl":"https://aoctrl.com/api/mcp/products/5SL4410-7","rawCanonicalId":null},"summary":{"shortDescription":"Siemens SENTRON 5SL4410-7, 4-pole miniature circuit breaker, C-curve 10 A, 400 V AC, 10 kA breaking capacity, 4 modular width units.","salesMarkdown":"## 4-pole C-curve 10 A MCB for 400 V distribution The Siemens SENTRON 5SL4410-7 is a 4-pole miniature circuit breaker rated 10 A with C-curve tripping characteristic, designed for 400 V AC multi-phase operation at 50/60 Hz. It breaks fault currents up to 10 kA per both EN 60898 and IEC 60947-2 — the same rating under both standards, so no coordination gap between residential and industrial application frameworks. The C-curve (5–10× In magnetic trip) suits it for mixed resistive and moderate inductive loads common in lighting, socket circuits, and small motor branch circuits in residential and infrastructure builds. ## Panel fit and mounting Occupies 4 modular width units (72 mm) on a standard DIN rail, with an installation depth of 70 mm and overall depth of 76 mm. Mounting position is unrestricted — any orientation works. The IP20 rating applies with connected conductors, so it's intended for enclosed distribution boards, not exposed wet locations. Sealable design allows the installer to lock the toggle position after commissioning, preventing unauthorized switching in shared-access panels. ## Environmental and compliance notes Halogen-free and silicon-free construction, rated for ambient temperatures from -40 °C to 75 °C. Overvoltage category III, pollution degree 2 — standard for fixed-installation distribution boards. Mechanical service life is 10 000 operating cycles typical. Power loss per pole at rated current in hot operating state is 0.9 W, which helps when calculating thermal load in a crowded enclosure.","metaTitle":"Siemens 5SL4410-7 SENTRON MCB, 4P C 10A 400V 10kA","metaDescription":"Siemens 5SL4410-7 SENTRON 4-pole C-curve miniature circuit breaker, 10 A, 400 V AC, 10 kA breaking capacity per EN 60898/IEC 60947-2. Active production, available to order.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":["4-Pole MCB (DIN Rail)"],"specifications":{"Depth":"76 mm","Width":"72 mm","title":"5SL4410-7","Height":"90 mm","Maximum":"75 °C","Minimum":"-40 °C","Sealable":"Yes","description":"Miniature circuit breaker 400 V 10kA, 4-pole, C, 10 A","Halogen-Free":"Yes","Silicon-Free":"Yes","Design Of Pole":"4P","Number Of Poles":"4","lifecycle_stage":"current","Mounting Position":"any","Installation Depth":"70 mm","Product Brand Name":"SENTRON","Degree Of Pollution":"2","Product Designation":"Miniature circuit breaker","protection class IP":"IP20, with connected conductors","Overvoltage Category":"III","Energy Limitation Class":"3","Suitability For Operation":"Residential buildings/infrastructure","at DC rated value maximum":"72 V","Number Of Modular Width Units":"4","Tripping Characteristic Class":"C","supply voltage at AC rated value":"400 V","according to EN 60898 rated value":"10 kA","according to IEC 60947-2 rated value":"10 kA","Type Of Voltage Of The Operating Voltage":"AC","with multi-phase operation at AC maximum":"440 V","Value Range Of The Supply Voltage Frequency":"50/60 Hz","with multi-phase operation at AC rated value":"440 V","Mechanical Service Life (Operating Cycles) Typical":"10 000","Product Extension Installable Supplementary Devices":"Yes","power loss [W] for rated value of the current at AC in hot operating state per pole":"0.9 W"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"stockQuantity":0,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/ad43b931801eb24b98c90e7f6e2824ba.pdf","sourceUrl":"https://support.industry.siemens.com/webbackend/api/ProductSupport/TechnicalData?language=en&region=cn&productId=251021&mlfb=5SL4410-7"},"ai":{"faq":[{"question":"What is the breaking capacity of the 5SL4410-7?","answer":"10 kA rated value under both EN 60898 and IEC 60947-2 at 400 V AC, so it meets the same fault-interruption rating for residential and industrial coordination studies."},{"question":"Will the 5SL4410-7 fit a panel designed for the 5SL4363-7?","answer":"No — the 5SL4410-7 is a 4-pole unit occupying 4 modular width units (72 mm), while the 5SL4363-7 is a 3-pole unit at 3 MWU (54 mm). The 5SL4410-7 is 18 mm wider and requires an additional pole's wiring space; it will not drop into a panel wired and spaced for the 3-pole variant without rework."},{"question":"Where can I buy the 5SL4410-7?","answer":"Sourced and quoted to order against an RFQ through independent distribution — availability and current pricing are confirmed at quote time. Submit an inquiry for a firm commercial offer."},{"question":"What compliance documentation does Siemens provide for the 5SL4410-7?","answer":"The part carries ratings per EN 60898 and IEC 60947-2, which imply CE marking for the European market. It is halogen-free and silicon-free. For specific declarations (RoHS, REACH, UL file number), request the manufacturer's current compliance documentation with your RFQ."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"icboms-matrix-langgraph","citationUrl":"https://aoctrl.com/siemens/5SL4410-7","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/siemens/5SL4410-7 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-08-11T15:51:03.652Z","lastPublished":"2026-08-11T15:51:03.652Z","indexable":true}}