{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"5SL4410-7RC","brand":"Siemens","brandSlug":"siemens","productSlug":"5SL4410-7RC","canonicalUrl":"https://aoctrl.com/siemens/5SL4410-7RC","factsUrl":"https://aoctrl.com/api/mcp/products/5SL4410-7RC","rawCanonicalId":null},"summary":{"shortDescription":"Siemens SENTRON 5SL4410-7RC miniature circuit breaker, 4-pole, C-curve, 10 A rated, 10 kA breaking capacity per EN 60898 at 415 V AC, 1 MW width.","salesMarkdown":"## Siemens 5SL4410-7RC — 4-pole C-curve MCB, 10 A, 10 kA The Siemens 5SL4410-7RC is a SENTRON miniature circuit breaker, 4-pole, C-curve, rated 10 A at 415 V AC with a 10 kA breaking capacity per EN 60898. That 10 kA at 415 V means it can safely interrupt a fault current up to 10,000 amps on a 415 V three-phase supply — enough for most residential and light commercial distribution boards in IEC territories. Occupies a single modular width unit (18 mm) per pole, so four poles fit in 72 mm of DIN-rail space. Depth is 76 mm, which is the standard SENTRON 5SL series footprint — it'll drop into any panel already kitted with these breakers without re-drilling or re-routing busbars. Rated 10 A at 30 °C ambient, with a 415 V AC supply voltage. The multi-phase maximum is 440 V AC, so it's fine on 400/415 V three-phase networks. Single-phase operation is rated at 250 V AC — that's the line-to-neutral voltage in a 415/240 V system. DC rating tops out at 72 V, which is enough for control circuits but not for high-voltage DC bus work. That's the standard for domestic and light commercial final circuits in most IEC countries. The energy limitation class is 3, meaning it limits let-through energy well enough for most downstream equipment protection. That's the standard for this class — not a contactor, but fine for occasional manual isolation or breaker-as-switch use in residential panels. For frequent switching duty, you'd want a dedicated disconnect. Snap-on DIN-rail mount, any position. Installation depth is 70 mm — the breaker body extends 70 mm behind the rail, plus the terminals. Sealable — you can wire-seal the toggle to prevent unauthorized operation. Touch protection is built in. Halogen-free and silicon-free — that matters for panels in environments where silicone outgassing can contaminate contacts or optics, and for fire-safety compliance in public buildings. Degree of pollution 2, overvoltage category III — standard for fixed-installation distribution boards. Neutral conductor is not switched — the 4-pole version switches all three phases but the neutral is solid through. If you need a switched neutral, look at the 5SL4...RC series with the 'N' designation.","metaTitle":"Siemens 5SL4410-7RC SENTRON MCB, 4P C 10A 10kA","metaDescription":"Siemens 5SL4410-7RC SENTRON miniature circuit breaker, 4-pole, C-curve, 10 A, 10 kA at 415 V AC. Active production. Sourced to order against RFQ.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":["4-Pole MCB (DIN Rail)"],"specifications":{"Depth":"76 mm","Width":"18 mm","title":"5SL4410-7RC","Height":"90 mm","Maximum":"75 °C","Minimum":"-40 °C","Sealable":"Yes","description":"Miniature circuit breaker 415 V 10kA, 4-pole, C, 10 A","Halogen-Free":"Yes","Silicon-Free":"Yes","Design Of Pole":"4P","Number Of Poles":"4","lifecycle_stage":"current","Mounting Position":"any","Installation Depth":"70 mm","Product Brand Name":"SENTRON","Degree Of Pollution":"2","Product Designation":"Miniature circuit breaker","acc. to IEC 81346-2":"F","at AC / rated value":"10 A","protection class IP":"IP20, with connected conductors","Overvoltage Category":"III","acc. to DIN EN 61346-2":"F","Energy Limitation Class":"3","at 30 °C / rated value":"10 A","Suitability For Operation":"Residential buildings/infrastructure","Number Of Modular Width Units":"1","Tripping Characteristic Class":"C","at DC / rated value / maximum":"72 V","acc. to EN 60898 / rated value":"10 kA","Product Feature / Touch Protection":"Yes","supply voltage / at AC / rated value":"415 V","Type Of Voltage / Of The Operating Voltage":"AC","with multi-phase operation / at AC / maximum":"440 V","Product Component / Neutral Conductor Switching":"No","with multi-phase operation / at AC / rated value":"440 V","with single-phase operation / at AC / rated value":"250 V","Mechanical Service Life (Switching Cycles) / Typical":"10 000"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"stockQuantity":0,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/ad43b931801eb24b98c90e7f6e2824ba.pdf","sourceUrl":"https://support.industry.siemens.com/webbackend/api/ProductSupport/TechnicalData?language=en&region=cn&productId=254365&mlfb=5SL4410-7RC"},"ai":{"faq":[{"question":"What is the breaking capacity of 5SL4410-7RC?","answer":"10 kA per EN 60898 at 415 V AC. That's the standard breaking capacity for domestic and light commercial final circuits in IEC countries."},{"question":"Will 5SL4410-7RC fit in a panel designed for 5SL3116-6MB?","answer":"Yes, the 5SL4410-7RC shares the same 76 mm depth, 18 mm per-pole width, and 90 mm height as the 5SL3116-6MB. Both snap onto standard DIN rail. The 5SL4410-7RC is 4-pole vs 1-pole, so it occupies 72 mm of rail width instead of 18 mm. If the panel busbar and wiring are sized for a 4-pole breaker, it's a direct mechanical fit."},{"question":"Where can I buy 5SL4410-7RC?","answer":"Sourced and quoted to order against an RFQ through independent distribution. Availability and current pricing are confirmed at quote time."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"icboms-matrix-langgraph","citationUrl":"https://aoctrl.com/siemens/5SL4410-7RC","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/siemens/5SL4410-7RC when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-08-11T15:51:03.652Z","lastPublished":"2026-08-11T15:51:03.652Z","indexable":true}}