{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"5SL4413-7RC","brand":"Siemens","brandSlug":"siemens","productSlug":"5SL4413-7RC","canonicalUrl":"https://aoctrl.com/siemens/5SL4413-7RC","factsUrl":"https://aoctrl.com/api/mcp/products/5SL4413-7RC","rawCanonicalId":null},"summary":{"shortDescription":"Siemens SENTRON 5SL4 series, 5SL4413-7RC miniature circuit breaker, 4-pole, C tripping characteristic, 13 A rated current, 10 kA breaking capacity at 415 V AC, 18 mm width per pole.","salesMarkdown":"## What it is and what it does The Siemens 5SL4413-7RC is a 4-pole SENTRON miniature circuit breaker with a C tripping characteristic, rated 13 A at 415 V AC. It breaks 10 kA per EN 60898, so it handles fault currents up to that level without welding contacts or cascading failure upstream. That's the standard residential and light-commercial interrupting rating — fine for distribution boards where the prospective short-circuit current stays under 10 kA. The C-curve means it trips between 5× and 10× rated current — typical for inductive loads like small motors, fluorescent lighting banks, and transformer primaries where you need to ride through inrush without nuisance tripping. At 13 A per pole, it's sized for a 3 kW three-phase motor or a mixed lighting/power subfeed. ## Panel fit and wiring Each pole occupies one 18 mm width unit — four poles across 72 mm of DIN-rail space. The 76 mm depth and 90 mm height keep it inside standard distribution board envelopes. Installation depth is 70 mm, so it clears shallow back panels. Terminals accept 0.75 to 25 mm² solid or stranded copper. Tightening torque is 2.5 to 3 N·m — a standard screwdriver setting, no special tooling. The breaker is sealable, which matters for utility-metered or tamper-proof installations. Touch protection is built in, and IP20 applies when conductors are connected — normal for enclosed distribution boards. ## What the ratings mean for your BOM line Rated voltage is 415 V AC for multi-phase operation, with a maximum of 440 V. Single-phase operation is rated at 250 V. Overvoltage category III means it's designed for fixed installation downstream of the main distribution board — not for equipment-level protection. Energy limiting class 3 gives good let-through energy reduction, which helps with downstream coordination. Mechanical service life is 10 000 switching cycles typical. Ambient temperature range is -25 to +55 °C, storage from -40 to +75 °C. Halogen-free and silicon-free construction — relevant for clean-room or corrosive-environment installations where outgassing matters.","metaTitle":"Siemens 5SL4413-7RC SENTRON MCB, 4P C 13A 10kA","metaDescription":"Siemens 5SL4413-7RC SENTRON miniature circuit breaker, 4-pole, C-curve, 13 A, 10 kA breaking capacity per EN 60898 at 415 V AC. Active production. Sourced to order against RFQ.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":["4-Pole MCB (DIN Rail)"],"specifications":{"Depth":"76 mm","Solid":"0.75 ... 25 mm²","Width":"18 mm","title":"5SL4413-7RC","Height":"90 mm","Sealable":"Yes","Stranded":"0.75 ... 25 mm²","Rated Value":"50 Hz","description":"Miniature circuit breaker 415 V 10kA, 4-pole, C, 13A","Halogen-Free":"Yes","Silicon-Free":"Yes","During Storage":"-40 ... +75 °C","Number of poles":"4","Type of voltage":"AC","lifecycle_stage":"current","Mounting position":"any","Installation depth":"70 mm","Product brand name":"SENTRON","Ambient temperature":"-25 ... +55 °C","Product designation":"Miniature circuit breaker","Protection class IP":"IP20, with connected conductors","Overvoltage category":"III","Design of the product":"5SL miniature circuit breakers","Energy limiting class":"3","Number of width units":"1","Number of poles / Note":"4P","acc. to DIN EN 61346-2":"F","acc. to DIN EN 81346-2":"F","circuit-breaker / Design":"5SL4","Suitability for operation":"Residential buildings/infrastructure","Current / at AC / rated value":"13 A","Tripping characteristic class":"C","acc. to EN 60898 / rated value":"10 kA","Product feature / Touch protection":"Yes","Supply voltage / at AC / rated value":"415 V","with multi-phase operation / at AC / maximum":"440 V","Tightening torque / with screw-type terminals":"2.5 ... 3 N·m","Product function / neutral conductor switching":"No","with multi-phase operation / at AC / rated value":"440 V","with single-phase operation / at AC / rated value":"250 V","Mechanical service life (switching cycles) / typical":"10 000"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"stockQuantity":0,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/ad43b931801eb24b98c90e7f6e2824ba.pdf","sourceUrl":"https://support.industry.siemens.com/webbackend/api/ProductSupport/TechnicalData?language=en&region=cn&productId=238623&mlfb=5SL4413-7RC"},"ai":{"faq":[{"question":"Where can I buy 5SL4413-7RC and what is the lead time?","answer":"We source this part to order against an RFQ through independent distribution. Availability and current pricing are confirmed at quote time — submit an RFQ for a firm lead time and price."},{"question":"Will 5SL4413-7RC drop into a panel specified around 5SL3120-6MB without rewiring?","answer":"Both are 4-pole SENTRON MCBs on the same 18 mm per-pole DIN footprint, so the mechanical fit is identical. The difference is the rating: 5SL4413-7RC is 13 A C-curve, while 5SL3120-6MB is a different current/trip combination — verify the load requirement before swapping."},{"question":"What compliance documentation does Siemens provide for 5SL4413-7RC?","answer":"The breaker is rated per EN 60898 for breaking capacity. It carries overvoltage category III and energy limiting class 3 designations. Halogen-free and silicon-free construction is specified. For specific certificates (UL, CSA, CE, RoHS, REACH), request the manufacturer's declaration with your RFQ."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"icboms-matrix-langgraph","citationUrl":"https://aoctrl.com/siemens/5SL4413-7RC","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/siemens/5SL4413-7RC when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-08-11T15:51:03.652Z","lastPublished":"2026-08-11T15:51:03.652Z","indexable":true}}