{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"5SL4501-7","brand":"Siemens","brandSlug":"siemens","productSlug":"5SL4501-7","canonicalUrl":"https://aoctrl.com/siemens/5SL4501-7","factsUrl":"https://aoctrl.com/api/mcp/products/5SL4501-7","rawCanonicalId":null},"summary":{"shortDescription":"Siemens SENTRON 5SL4501-7, miniature circuit breaker, 1P+N, C characteristic, 1 A rated, 230 V AC, 10 kA breaking capacity per EN 60898 and IEC 60947-2, 2 MW units, IP20.","salesMarkdown":"## What it is and where it goes The Siemens 5SL4501-7 is a SENTRON miniature circuit breaker (MCB) with a 1P+N pole design — it switches the phase and monitors the neutral, but does not switch the neutral. Rated 1 A at 230 V AC with a C tripping characteristic, it breaks fault currents up to 10 kA per EN 60898 and IEC 60947-2. That 10 kA SCCR means it can safely interrupt a short-circuit up to that level without welding the contacts or cascading the fault upstream — critical for selectivity in a distribution board. It occupies 2 modular width units (36 mm) on a DIN rail and is rated IP20 with conductors connected, so it lives inside an enclosure, not on a washdown line. ## What the ratings mean for fit The C-curve means the magnetic trip operates at 5 to 10 times the rated current — so for a 1 A breaker, the instantaneous trip point is between 5 A and 10 A. That suits lighting, control transformers, and small motor loads with moderate inrush. The 10 kA breaking capacity at 230 V AC is standard for residential and light commercial distribution boards. Temperature derating is baked in: at 40 °C ambient the breaker carries 0.95 A, at 55 °C it drops to 0.86 A — so if the panel runs hot, size up one step. Power loss per pole is 1.2 W at rated current; in a crowded enclosure with several breakers, that heat adds up and affects the derating curve. ## Panel integration notes Mounts in any position on a 35 mm DIN rail. Depth is 76 mm overall; installation depth (behind the panel face) is 70 mm. The housing is halogen-free and silicon-free — relevant if the panel is in a clean room or a zone where outgassing matters. Sealable with a lockable cover or padlock accessory to prevent unauthorized switching. Supplementary devices (auxiliary contacts, shunt trips, alarm switches) can be added on the right side without extra wiring space.","metaTitle":"Siemens 5SL4501-7 SENTRON MCB, 1P+N, C-curve, 1 A, 10 kA","metaDescription":"Siemens 5SL4501-7 SENTRON miniature circuit breaker, 1P+N, 230 V AC, 10 kA, C characteristic, 1 A. Active production. Sourced to order against RFQ.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":[],"specifications":{"Depth":"76 mm","Poles":"2","Width":"36 mm","Height":"90 mm","IP Rating":"IP20","Product Status":"Active","Energy Limitation Class":"3"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/3ce392804f2af16e298b4cc6cab875e3.pdf","sourceUrl":"https://support.industry.siemens.com/webbackend/api/ProductSupport/TechnicalData?language=en&region=cn&productId=323151&mlfb=5SL4501-7","alternativesUrl":"https://aoctrl.com/api/mcp/products/5SL4501-7/alternatives.json"},"ai":{"faq":[],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/siemens/5SL4501-7","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/siemens/5SL4501-7 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}