{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"5SL4506-6","brand":"Siemens","brandSlug":"siemens","productSlug":"5SL4506-6","canonicalUrl":"https://aoctrl.com/siemens/5SL4506-6","factsUrl":"https://aoctrl.com/api/mcp/products/5SL4506-6","rawCanonicalId":null},"summary":{"shortDescription":"Siemens SENTRON 5SL4506-6 miniature circuit breaker, 230 V AC, 10 kA, 1P+N, B-curve, 6 A.","salesMarkdown":"The Siemens 5SL4506-6 is a SENTRON miniature circuit breaker (MCB) rated 6 A with a B tripping characteristic, 10 kA breaking capacity per EN 60898 and IEC 60947-2, and a 1P+N pole configuration for 230 V AC single-phase circuits. The B-curve means it trips at 3–5× rated current, suited for resistive and general-purpose loads where inrush is modest — lighting, small appliances, and control transformers in residential or light commercial infrastructure panels. ## Panel fit and integration Occupies 2 modular width units (36 mm) on a DIN rail, with a depth of 76 mm and installation depth of 70 mm. Mounting position is unrestricted. IP20 with connected conductors — suitable for enclosed distribution boards. The housing is halogen-free and silicon-free, and the unit is sealable for tamper-proof installations. Supplementary devices (auxiliary switches, shunt trips, alarm contacts) can be added on the side.","metaTitle":"Siemens 5SL4506-6 SENTRON MCB, 6A 10kA B-Curve 1P+N","metaDescription":"Siemens 5SL4506-6 SENTRON miniature circuit breaker, 6A, 10kA breaking capacity, B-curve, 1P+N, 230V AC. Active production. Sourced to order against RFQ.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":["1-Pole MCB (DIN Rail)"],"specifications":{"Depth":"76 mm","Width":"36 mm","title":"5SL4506-6","Height":"90 mm","Maximum":"75 °C","Minimum":"-40 °C","Sealable":"Yes","description":"Miniature circuit breaker 230 V 10kA, 1+N-pole, B, 6A","Halogen-Free":"Yes","Silicon-Free":"Yes","Design Of Pole":"1P+N","Number Of Poles":"2","lifecycle_stage":"current","Mounting Position":"any","Installation Depth":"70 mm","Product Brand Name":"SENTRON","Degree Of Pollution":"2","Product Designation":"Miniature circuit breaker","protection class IP":"IP20, with connected conductors","Overvoltage Category":"III","Energy Limitation Class":"3","Suitability For Operation":"Residential buildings/infrastructure","at DC rated value maximum":"72 V","Number Of Modular Width Units":"2","Tripping Characteristic Class":"B","supply voltage at AC rated value":"230 V","according to EN 60898 rated value":"10 kA","according to IEC 60947-2 rated value":"10 kA","Type Of Voltage Of The Operating Voltage":"AC","Value Range Of The Supply Voltage Frequency":"50/60 Hz","with single-phase operation at AC rated value":"250 V","Mechanical Service Life (Operating Cycles) Typical":"10 000","Product Extension Installable Supplementary Devices":"Yes","power loss [W] for rated value of the current at AC in hot operating state per pole":"1.9 W"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":"$10.67","stockQuantity":0,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/3ce392804f2af16e298b4cc6cab875e3.pdf","sourceUrl":"https://support.industry.siemens.com/webbackend/api/ProductSupport/TechnicalData?language=en&region=cn&productId=359061&mlfb=5SL4506-6"},"ai":{"faq":[{"question":"What are the key ratings of the 5SL4506-6?","answer":"6 A rated current, B-curve (trips at 3–5× In), 10 kA breaking capacity per EN 60898 and IEC 60947-2, 230 V AC single-phase, 1P+N poles, 2 modular width units (36 mm)."},{"question":"Where can I buy the 5SL4506-6?","answer":"Sourced and quoted to order against an RFQ through independent industrial-automation distribution. Availability and current pricing are confirmed at quote time."},{"question":"Will the 5SL4506-6 drop into a panel specified around the 5SL4363-7?","answer":"No — the 5SL4363-7 is a 3-pole, 3-module-width (54 mm) C-curve breaker at 400 V AC, while the 5SL4506-6 is a 1P+N, 2-module-width (36 mm) B-curve unit at 230 V. The footprint, pole count, and voltage ratings differ, so direct swap without rewiring is not possible."},{"question":"What compliance documentation does Siemens provide for the 5SL4506-6?","answer":"The 5SL4506-6 carries ratings per EN 60898 and IEC 60947-2, with IP20 protection, overvoltage category III, and pollution degree 2. The halogen-free and silicon-free construction supports environmental compliance requirements typical for residential and infrastructure installations."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"icboms-matrix-langgraph","citationUrl":"https://aoctrl.com/siemens/5SL4506-6","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/siemens/5SL4506-6 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-08-11T15:51:03.652Z","lastPublished":"2026-08-11T15:51:03.652Z","indexable":true}}