{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"5SL4604-7","brand":"Siemens","brandSlug":"siemens","productSlug":"5SL4604-7","canonicalUrl":"https://aoctrl.com/siemens/5SL4604-7","factsUrl":"https://aoctrl.com/api/mcp/products/5SL4604-7","rawCanonicalId":null},"summary":{"shortDescription":"Siemens SENTRON 5SL4 series, 5SL4604-7 miniature circuit breaker, 4 A, C-curve, 4-pole (3P+N), 10 kA breaking capacity per EN 60898 / IEC 60947-2, 400 V AC, 76 mm depth.","salesMarkdown":"## What this 4-pole MCB does on the line The Siemens 5SL4604-7 is a 4-pole (3P+N) miniature circuit breaker from the SENTRON 5SL4 series, rated 4 A with a C-curve tripping characteristic. The integrated neutral pole switches the neutral conductor, which simplifies wiring in single-phase or three+N distribution boards. ## Panel fit and wiring constraints The 5SL4604-7 occupies 4 width units (72 mm) on a DIN rail, with a depth of 76 mm and an installation depth of 70 mm. It accepts solid or stranded conductors from 0.75 mm² up to 25 mm², with a recommended tightening torque of 2.5 to 3 N·m on the screw terminals. It is designed for any mounting position, which gives flexibility in tight enclosures. The overvoltage category is 3, and the energy limiting class is 3 — meaning it limits let-through energy effectively for downstream equipment protection. The product carries the standard Siemens compliance documentation for CE, RoHS, and REACH; specific UL or IEC certificates are available on request with the order.","metaTitle":"Siemens 5SL4604-7 SENTRON MCB, 4A C-Curve 4P 10kA 400V","metaDescription":"Siemens 5SL4604-7 SENTRON miniature circuit breaker, 4 A, C-curve, 4-pole (3P+N), 10 kA breaking capacity per EN 60898/IEC 60947-2, 400 V AC. Current lifecycle. Quoted to order.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":["4-Pole MCB (DIN Rail)"],"specifications":{"Depth":"76 mm","Solid":"0.75 ... 25 mm²","Width":"72 mm","title":"5SL4604-7","Height":"90 mm","Sealable":"Yes","Stranded":"0.75 ... 25 mm²","Rated Value":"50 Hz","description":"Miniature circuit breaker 400 V 10kA, 3+N-pole, C, 4A","Halogen-Free":"Yes","Silicon-Free":"Yes","During Storage":"-40 ... +75 °C","Number of poles":"4","Type of voltage":"AC","lifecycle_stage":"current","Mounting position":"any","Installation depth":"70 mm","Product brand name":"SENTRON","Ambient temperature":"-25 ... +55 °C","Product designation":"Miniature circuit breaker","Protection class IP":"IP20, with connected conductors","Overvoltage category":"3","Design of the product":"5SL miniature circuit breakers","Energy limiting class":"3","Number of width units":"4","Number of poles / Note":"3P+N","acc. to DIN EN 61346-2":"F","acc. to DIN EN 81346-2":"F","circuit-breaker / Design":"5SL4","Suitability for operation":"Residential buildings/infrastructure","Current / at AC / rated value":"4 A","Tripping characteristic class":"C","at DC / rated value / maximum":"60 V","acc. to EN 60898 / rated value":"10 kA","acc. to IEC 60947-2 / rated value":"10 kA","Product feature / Touch protection":"Yes","Supply voltage / at AC / rated value":"400 V","Influence of the surrounding temperature":"+55 °C, max. 95% humidity","with multi-phase operation / at AC / maximum":"440 V","Tightening torque / with screw-type terminals":"2.5 ... 3 N·m","Product function / neutral conductor switching":"Yes","with multi-phase operation / at AC / rated value":"440 V","Mechanical service life (switching cycles) / typical":"10 000"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"stockQuantity":0,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/fe0607c969e3cb56ae4acad7134d99c5.pdf","sourceUrl":"https://support.industry.siemens.com/webbackend/api/ProductSupport/TechnicalData?language=en&region=cn&productId=71638&mlfb=5SL4604-7"},"ai":{"faq":[{"question":"What is the breaking capacity of the 5SL4604-7?","answer":"The 5SL4604-7 has a rated breaking capacity of 10 kA per both EN 60898 and IEC 60947-2 at 400 V AC. This is sufficient for most residential and light commercial distribution boards where the prospective short-circuit current is under 10 kA."},{"question":"What conductor sizes does the 5SL4604-7 accept?","answer":"The screw terminals accept solid or stranded conductors from 0.75 mm² up to 25 mm². The recommended tightening torque is 2.5 to 3 N·m."},{"question":"Where can I buy the 5SL4604-7 and how is it quoted?","answer":"The 5SL4604-7 is sourced to order through our independent distribution network. Submit an RFQ for current pricing and availability — we confirm both at quote time for your required quantity and delivery schedule."},{"question":"Will the 5SL4604-7 fit in a panel designed for the 5SL6606-7YA?","answer":"Both are 4-pole SENTRON 5SL series MCBs on the same DIN-rail footprint, so the 5SL4604-7 will physically drop into the same panel position without rewiring. The key difference is the current rating: 4 A (C-curve) versus the 5SL6606-7YA's rating — verify the load requirement before substituting."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"icboms-matrix-langgraph","citationUrl":"https://aoctrl.com/siemens/5SL4604-7","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/siemens/5SL4604-7 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-08-11T15:51:03.652Z","lastPublished":"2026-08-11T15:51:03.652Z","indexable":true}}