{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"5SL4610-6CC","brand":"Siemens","brandSlug":"siemens","productSlug":"5SL4610-6CC","canonicalUrl":"https://aoctrl.com/siemens/5SL4610-6CC","factsUrl":"https://aoctrl.com/api/mcp/products/5SL4610-6CC","rawCanonicalId":null},"summary":{"shortDescription":"Siemens SENTRON 5SL miniature circuit breaker, 4-pole (3P+N), 10 A rated, B tripping characteristic, 10 kA breaking capacity per EN 60898, 400 V AC, depth 76 mm, solid/stranded 0.75–25 mm².","salesMarkdown":"## What this 4-pole MCB brings to a panel That's enough for most building-distribution boards where the upstream device provides the back-up limitation. The 72 mm wide body (4 width units on a DIN rail) snaps into any standard 35 mm rail enclosure. Mounting position is unrestricted, so you can orient it vertically, horizontally, or flat — useful when you're squeezing a sub-distribution board into a tight utility closet. ## Where it fits — and where it doesn't The B-curve characteristic (3–5× In) is deliberately chosen for circuits where the load is mostly resistive or has a short inrush — think lighting, socket outlets, control transformers. If you're feeding motor starters or drives with a longer inrush, a C-curve (5–10× In) would be a better match to avoid nuisance trips. The 10 A rating limits this breaker to circuits drawing under about 2.3 kW per phase at 400 V three-phase, or 2.3 kW single-phase at 230 V. The neutral pole is switched, so you get full isolation on all four poles when the breaker is off — no floating neutral downstream. Storage range is wider at -40 to +75 °C. Overvoltage category 3 means it's rated for fixed-installation distribution boards, not for equipment-level protection.","metaTitle":"Siemens 5SL4610-6CC SENTRON MCB, 4P, 10A, B Curve, 10kA","metaDescription":"Siemens 5SL4610-6CC SENTRON miniature circuit breaker, 4-pole 3P+N, 10 A, B characteristic, 10 kA per EN 60898. Current-production part, available to order. Depth 76 mm, solid/stra","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":["4-Pole MCB (DIN Rail)"],"specifications":{"Depth":"76 mm","Solid":"0.75 ... 25 mm²","Width":"72 mm","title":"5SL4610-6CC","Height":"90 mm","Sealable":"Yes","Stranded":"0.75 ... 25 mm²","Rated Value":"50 Hz","description":"Miniature circuit breaker 400 V 10kA, 3+N-pole, B, 10 A Circuit breaker 400 V 10kA, 3+N-pole, B, 10 A","Halogen-Free":"Yes","Silicon-Free":"Yes","During Storage":"-40 ... +75 °C","Number of poles":"4","Type of voltage":"AC","lifecycle_stage":"current","Mounting position":"any","Installation depth":"70 mm","Product brand name":"SENTRON","Ambient temperature":"-25 ... +55 °C","Product designation":"Miniature circuit breaker","Protection class IP":"IP20, with connected conductors","Overvoltage category":"3","Design of the product":"5SL miniature circuit breakers","Energy limiting class":"3","Number of width units":"4","Number of poles / Note":"3P+N","acc. to DIN EN 61346-2":"F","acc. to DIN EN 81346-2":"F","circuit-breaker / Design":"5SL4CC","Suitability for operation":"Residential buildings/infrastructure","Current / at AC / rated value":"10 A","Tripping characteristic class":"B","at DC / rated value / maximum":"60 V","acc. to EN 60898 / rated value":"10 kA","Product feature / Touch protection":"Yes","Supply voltage / at AC / rated value":"400 V","Influence of the surrounding temperature":"+55 °C, max. 95% humidity","Vibration resistance / acc. to IEC 60068-2-6":"50 m/s² at 25 to 150 Hz","with multi-phase operation / at AC / maximum":"440 V","Tightening torque / with screw-type terminals":"2.5 ... 3 N·m","Product function / neutral conductor switching":"Yes","with multi-phase operation / at AC / rated value":"440 V"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"stockQuantity":0,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/c10d9f3167db9ac5897614c07c49f6bf.pdf","sourceUrl":"https://support.industry.siemens.com/webbackend/api/ProductSupport/TechnicalData?language=en&region=cn&productId=286425&mlfb=5SL4610-6CC"},"ai":{"faq":[{"question":"Where can I buy 5SL4610-6CC and how do I get a price?","answer":"This part is sourced and quoted to order against an RFQ through independent distribution. Availability and current pricing are confirmed at quote time — submit an RFQ for a firm price and lead time."},{"question":"What is the closest functional second-source for 5SL4610-6CC?","answer":"The 5SL6606-7YA is a 4-pole MCB in the same SENTRON 5SL family, but it is a 6 A C-curve device with a 6 kA breaking capacity. It is not a functional second-source for a 10 A B-curve application. For a direct electrical match, stay within the 5SL4CC design variant with the same current and curve."},{"question":"What is the depth of 5SL4610-6CC?","answer":"The overall depth is 76 mm. The installation depth behind the panel face is 70 mm. The extra 6 mm accounts for the screw terminals."},{"question":"What conductor sizes does 5SL4610-6CC accept?","answer":"It accepts solid and stranded copper from 0.75 mm² up to 25 mm². The tightening torque range is 2.5 to 3 N·m."},{"question":"Will 5SL4610-6CC drop into a panel specified around 5SL6606-7YA without rewiring?","answer":"Yes, the physical footprint is identical — both are 4-pole (3P+N), 72 mm wide, and use the same terminal range (0.75–25 mm²). No rewiring of the busbar or load cables is needed. However, the B curve of the 5SL4610-6CC trips faster on moderate overcurrents than the C curve of the 5SL6606-7YA, so the selectivity coordination with the upstream breaker must be re-evaluated."},{"question":"What compliance documentation does Siemens provide for 5SL4610-6CC?","answer":"As a current-production SENTRON catalogue item, the standard documentation includes CE declaration of conformity, RoHS and REACH compliance statements, and the EN 60898 test certificate for the 10 kA breaking capacity. The part is also halogen-free and silicon-free, which is documented in the material declaration."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"icboms-matrix-langgraph","citationUrl":"https://aoctrl.com/siemens/5SL4610-6CC","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/siemens/5SL4610-6CC when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-08-11T15:51:03.652Z","lastPublished":"2026-08-11T15:51:03.652Z","indexable":true}}