{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"5SL4613-8CC","brand":"Siemens","brandSlug":"siemens","productSlug":"5SL4613-8CC","canonicalUrl":"https://aoctrl.com/siemens/5SL4613-8CC","factsUrl":"https://aoctrl.com/api/mcp/products/5SL4613-8CC","rawCanonicalId":null},"summary":{"shortDescription":"Siemens SENTRON 5SL miniature circuit breaker, 4-pole (3P+N), D tripping characteristic, 13 A rated current, 10 kA breaking capacity per EN 60898, 400 V AC, 4 width units.","salesMarkdown":"The Siemens SENTRON 5SL4613-8CC is a 4-pole (3P+N) miniature circuit breaker rated 13 A with a D tripping characteristic, breaking 10 kA per EN 60898 at 400 V AC. Lifecycle status is active per the manufacturer record. The halogen-free and silicon-free construction simplifies compliance documentation for RoHS and REACH declarations — relevant if your quality system requires full material disclosure per IATF 16949 or similar. ## Physical fit & mounting Any mounting position is allowed. Conductor range 0.75 mm² to 25 mm², and the terminals are sealable — a feature for panel builders who need to lock out adjustments after commissioning. IP20 with connected conductors, so it belongs inside a closed enclosure, not exposed to washdown or dust. ## Coordination note The single-pole peer 5SL4120-7CC (20 A, C-curve) shares the same 76 mm depth and 90 mm height but is 18 mm wide — one width unit. It will not drop into a panel cutout or DIN-rail position sized for the 4-pole 5SL4613-8CC without adding three adjacent slots and rewiring the neutral leg (the single-pole version does not switch neutral). If your panel was laid out for the 5SL4120-7CC, the 5SL4613-8CC needs 72 mm of rail space, not 18 mm. Rated for vibration per IEC 60068-2-6 at 50 m/s² over 25 to 150 Hz. Ambient temperature limit is +55 °C with up to 95% humidity. Overvoltage category III, touch protection fitted.","metaTitle":"Siemens 5SL4613-8CC SENTRON MCB, 4P D 13A 10kA","metaDescription":"Siemens 5SL4613-8CC SENTRON MCB, 4-pole (3P+N), D-curve, 13 A, 10 kA per EN 60898, 400 V AC. Active production. Quoted to order.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":["4-Pole MCB (DIN Rail)"],"specifications":{"Depth":"76 mm","Width":"72 mm","title":"5SL4613-8CC","Height":"90 mm","Maximum":"25 mm²","Minimum":"0.75 mm²","Sealable":"Yes","Rated Value":"50 Hz","description":"Miniature circuit breaker 400 V 10kA, 3+N-pole, D, 13A Circuit breaker 400 V 10kA, 3+N-pole, D, 13A","Halogen-Free":"Yes","Silicon-Free":"Yes","Number of poles":"4","Type of voltage":"AC","lifecycle_stage":"current","Mounting position":"any","Installation depth":"70 mm","Product brand name":"SENTRON","Product designation":"Miniature circuit breaker","Protection class IP":"IP20, with connected conductors","Overvoltage category":"3","Design of the product":"5SL miniature circuit breakers","Number of width units":"4","Number of poles / Note":"3P+N","acc. to DIN EN 61346-2":"F","acc. to DIN EN 81346-2":"F","circuit-breaker / Design":"5SL4CC","Suitability for operation":"Residential buildings/infrastructure","Current / at AC / rated value":"13 A","Tripping characteristic class":"D","at DC / rated value / maximum":"60 V","acc. to EN 60898 / rated value":"10 kA","Product feature / Touch protection":"Yes","Supply voltage / at AC / rated value":"400 V","Influence of the surrounding temperature":"+55 °C, max. 95% humidity","Vibration resistance / acc. to IEC 60068-2-6":"50 m/s² at 25 to 150 Hz","with multi-phase operation / at AC / maximum":"440 V","Product function / neutral conductor switching":"Yes","with multi-phase operation / at AC / rated value":"440 V"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"stockQuantity":0,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/c10d9f3167db9ac5897614c07c49f6bf.pdf","sourceUrl":"https://support.industry.siemens.com/webbackend/api/ProductSupport/TechnicalData?language=en&region=cn&productId=498781&mlfb=5SL4613-8CC"},"ai":{"faq":[{"question":"What is the breaking capacity of 5SL4613-8CC?","answer":"10 kA per EN 60898 at 400 V AC. That rating is the short-circuit capacity the breaker can safely interrupt under standard test conditions."},{"question":"Will 5SL4613-8CC fit in a panel designed for 5SL4120-7CC?","answer":"No. The 5SL4613-8CC is 72 mm wide (4 width units) and switches 3 phases plus neutral. The 5SL4120-7CC is 18 mm wide (1 width unit) and switches a single pole without neutral. The panel cutout and DIN-rail allocation are incompatible without rework."},{"question":"Where can I buy 5SL4613-8CC?","answer":"Sourced and quoted to order against an RFQ through independent industrial-automation distribution. Availability and current pricing are confirmed at quote time — no stock count or lead-time number is published here."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"icboms-matrix-langgraph","citationUrl":"https://aoctrl.com/siemens/5SL4613-8CC","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/siemens/5SL4613-8CC when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-08-11T15:51:03.652Z","lastPublished":"2026-08-11T15:51:03.652Z","indexable":true}}