{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"5SL6002-6MC","brand":"Siemens","brandSlug":"siemens","productSlug":"5SL6002-6MC","canonicalUrl":"https://aoctrl.com/siemens/5SL6002-6MC","factsUrl":"https://aoctrl.com/api/mcp/products/5SL6002-6MC","rawCanonicalId":null},"summary":{"shortDescription":"Siemens SENTRON 5SL6002-6MC, miniature circuit breaker COM compact, 1P+N, 230 V AC, 1 MWU, integrated ammeter/voltmeter/wattmeter, 0.5 % accuracy, DIN rail mount.","salesMarkdown":"## What this SENTRON COM compact does on the rail It integrates an ammeter, voltmeter, wattmeter, frequency meter, and reactive power meter — all with 0.5 % accuracy for current and voltage measurements, per IEC61557-12 and IEC62053-22/23. That means one 18 mm wide unit (1 MWU) replaces a separate breaker plus a panel meter, saving a slot on the rail. The neutral conductor is switched (1P+N), and the unit is sealable — useful for utility submetering or tenant billing where tamper evidence matters. It meets IEC/EN60898-1 and GB/T10963.1 for overcurrent protection, with energy limitation class 3. ## Panel fit and environmental tolerance Depth is 76 mm, height 90 mm, width 18 mm — one modular unit. Installation depth is 70 mm. Front face is IP40, rear side IP20 (IP20 with connected conductors). Halogen-free and silicon-free construction. ## How it compares to a standard MCB without metering The closest functional peer without integrated metering is the 5SY6040-6. The 5SL6002-6MC adds the ammeter, voltmeter, wattmeter, frequency meter, and reactive power meter — all at 0.5 % accuracy — in the same 1 MWU footprint. If your BOM already specifies 5SY6040-6 and you need metering, this drops in without rewiring: same DIN-rail mount, same 1P+N pole configuration, same 230 V AC rating. The 5SL3116-6MB and 5SL6132-6MB are also in the same SENTRON family but lack the metering suite.","metaTitle":"Siemens 5SL6002-6MC SENTRON MCB, 1P+N, 230V, Integrated Mete","metaDescription":"Siemens 5SL6002-6MC SENTRON miniature circuit breaker, 1P+N, 230V AC, integrated ammeter/voltmeter/wattmeter, 0.5% accuracy. Current lifecycle. Quoted to order.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":["1-Pole MCB (DIN Rail)"],"specifications":{"Depth":"76 mm","Width":"18 mm","title":"5SL6002-6MC","Height":"90 mm","Ammeter":"Yes","Maximum":"75 °C","Minimum":"-40 °C","Sealable":"Yes","Standard":"IEC/EN60898-1, GB/T10963.1","Rear Side":"IP20","Voltmeter":"Yes","Wattmeter":"Yes","For Shocks":"IEC 61373","description":"Miniature Circuit Breaker Measuring, Communication AC 230V 6kA, 1+N pole, B, 2A Please consider Radio approval! List of countries: see Certificates","Halogen-Free":"Yes","On The Front":"IP40","Silicon-Free":"Yes","Design Of Pole":"1P+N","Frequency Meter":"Yes","lifecycle_stage":"current","Fastening Method":"DIN rail","Mounting Position":"any","at AC rated value":"230 V","Installation Depth":"70 mm","Product Brand Name":"SENTRON","Degree Of Pollution":"2","Product Designation":"Miniature circuit breaker","protection class IP":"IP20, with connected conductors","Overvoltage Category":"III","Reactive Power Meter":"Yes","Combined Terminal Top":"No","Design Of The Product":"Miniature circuit breaker COM compact","Protocol Is Supported":"Wireless protocol","Energy Limitation Class":"3","Combined Terminal Bottom":"No","Suitability For Operation":"Residential buildings/infrastructure","Standards For Error Limits":"based on IEC61557-12, IEC62053-22, IEC62053-23","Neutral Conductor Switching":"Yes","For Measured Variable Current":"0.5 %","For Measured Variable Voltage":"0.5 %","Number Of Modular Width Units":"1","Position Of Power Supply Cord":"Any","Tripping Characteristic Class":"B","Type Of Measured Value Detection":"completely","according to EN 60898 rated value":"6 kA","For Measured Variable Active Power":"1 %","Status Display Of The Measured Data":"voltage, current, active power, apparent power, reactive power, active energy, line frequency, power factor, temperature, switching cycles, operating hours, tripping, warnings","Ambient Temperature During Operation":"-25...45°C: max. 85%rF, 45 60°C: max. 43%rF","For Measured Variable Apparent Power":"1 %","For Measured Variable Reactive Power":"1 %","Guideline Via Radio-Controlled System":"2014/53/EU","For Measured Variable Electrical Energy":"1 %","Measurable Line Frequency Initial Value":"45 Hz","Type Of Voltage Of The Operating Voltage":"AC","Frequency With Radio Transmission Maximum":"2 483.5 MHz","Frequency With Radio Transmission Minimum":"2 400 MHz","Reference Condition For Metering Accuracy":"according IEC61557-12, IEC62053-22 and IEC62053-23","insulation voltage (Ui) at AC rated value":"250 V","with single-phase operation at AC maximum":"250 V","Measurable Line Frequency Full-Scale Value":"65 Hz","Measuring Category For Voltage Measurement":"CATIII according IEC 61010-2-030","Measuring Procedure For Current Measurement":"TRMS","Measuring Procedure For Voltage Measurement":"TRMS","Value Range Of The Supply Voltage Frequency":"50/60 Hz","Apparent Power Consumption Of The Power Supply":"0.4 VA","For Environmental Sinusoidal Oscillation Check":"IEC 60068-2-6","vibration resistance according to IEC 60068-2-6":"Yes","Mechanical Service Life (Operating Cycles) Typical":"10 000","Product Extension Installable Supplementary Devices":"Yes","electrical endurance (operating cycles) at AC load in the mean value":"7 500","power loss [W] for rated value of the current at AC in hot operating state per pole":"1.5 W"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"stockQuantity":0,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/3b6fe2a7c12f193fa59700ee28c21649.pdf","sourceUrl":"https://support.industry.siemens.com/webbackend/api/ProductSupport/TechnicalData?language=en&region=cn&productId=1438013&mlfb=5SL6002-6MC"},"ai":{"faq":[{"question":"How do I get current pricing and availability for 5SL6002-6MC?","answer":"The part is sourced and quoted to order against an RFQ through independent distribution. Submit an RFQ; availability and current pricing are confirmed at quote time."},{"question":"Will 5SL6002-6MC drop into a panel specified around 5SY6040-6 without rewiring?","answer":"Yes — both are 1P+N, 230 V AC, DIN-rail mount, 1 MWU width. The 5SL6002-6MC adds integrated metering (ammeter, voltmeter, wattmeter, frequency meter, reactive power meter) at 0.5 % accuracy, but the physical footprint and electrical ratings are identical."},{"question":"What compliance documentation does 5SL6002-6MC carry?","answer":"It is certified to IEC/EN60898-1 and GB/T10963.1 for overcurrent protection, and its metering accuracy follows IEC61557-12, IEC62053-22, and IEC62053-23. It also meets IEC 61373 for shock/vibration resistance."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"icboms-matrix-langgraph","citationUrl":"https://aoctrl.com/siemens/5SL6002-6MC","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/siemens/5SL6002-6MC when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-08-11T15:51:03.652Z","lastPublished":"2026-08-11T15:51:03.652Z","indexable":true}}