{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"5SL6004-7","brand":"Siemens","brandSlug":"siemens","productSlug":"5SL6004-7","canonicalUrl":"https://aoctrl.com/siemens/5SL6004-7","factsUrl":"https://aoctrl.com/api/mcp/products/5SL6004-7","rawCanonicalId":null},"summary":{"shortDescription":"Siemens SENTRON miniature circuit breaker, 5SL6004-7, 1P+N, C-characteristic, 6 kA breaking capacity per IEC/EN 60898-1, 230 V AC, 60 V DC, 1 modular width, DIN-rail mount.","salesMarkdown":"Rated 6 kA breaking capacity per IEC/EN 60898-1 at 230 V AC, it clears a fault up to that level without welding the contacts — enough for most final subcircuits in a TN or TT system. The 60 V DC rating covers control-voltage applications like relay coils or solenoid valves on a 48 V or 60 V DC bus. Snaps onto a standard 35 mm DIN rail and occupies 1 modular width unit (18 mm,). The 76 mm depth and 70 mm installation depth mean it sits flush in a distribution board with standard 80 mm deep enclosures — no need to oversize the box. Mounting position is unrestricted, so it can be installed horizontally in a shallow panel if needed. Designed to IEC/EN 60898-1 and GB/T10963.1. Halogen-free and silicon-free construction reduces corrosive off-gassing in a fire — relevant for installations in data centers or clean rooms. The part is sealable for anti-tamper applications. Vibration resistance per IEC 60068-2-6 is verified, and the mechanical service life is rated at 4 000 operating cycles typical.","metaTitle":"Siemens 5SL6004-7 SENTRON MCB, 1P+N, C4, 6kA, 230V","metaDescription":"Siemens 5SL6004-7 SENTRON miniature circuit breaker, 1P+N, C-curve, 6kA per IEC/EN 60898-1, 230V AC, 60V DC. Halogen-free, silicon-free, DIN-rail mount. Quoted to order.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":["1-Pole MCB (DIN Rail)"],"specifications":{"Depth":"76 mm","Width":"18 mm","title":"5SL6004-7","Height":"90 mm","Maximum":"75 °C","Minimum":"-40 °C","Sealable":"Yes","Standard":"IEC/EN60898-1, GB/T10963.1","description":"CIRCUIT BREAKER 230V 6KA, 1+N-POLE/1MW C4","Halogen-Free":"Yes","Silicon-Free":"Yes","Design Of Pole":"1P+N","lifecycle_stage":"current","Fastening Method":"DIN rail","Mounting Position":"any","at AC rated value":"230 V","at DC rated value":"60 V","Installation Depth":"70 mm","Product Brand Name":"SENTRON","Degree Of Pollution":"2","Product Designation":"Miniature circuit breaker","protection class IP":"IP20, with connected conductors","Overvoltage Category":"III","Combined Terminal Top":"No","Design Of The Product":"Miniature circuit breaker compact","Energy Limitation Class":"3","Combined Terminal Bottom":"No","Suitability For Operation":"Residential buildings/infrastructure","Neutral Conductor Switching":"Yes","Number Of Modular Width Units":"1","Position Of Power Supply Cord":"Any","Tripping Characteristic Class":"C","according to EN 60898 rated value":"6 kA","Type Of Voltage Of The Operating Voltage":"AC","insulation voltage (Ui) at AC rated value":"250 V","with single-phase operation at AC maximum":"250 V","Value Range Of The Supply Voltage Frequency":"50/60 Hz","vibration resistance according to IEC 60068-2-6":"Yes","Mechanical Service Life (Operating Cycles) Typical":"4 000","Product Extension Installable Supplementary Devices":"Yes","power loss [W] for rated value of the current at AC in hot operating state per pole":"2 W"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"stockQuantity":0,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/3b6fe2a7c12f193fa59700ee28c21649.pdf","sourceUrl":"https://support.industry.siemens.com/webbackend/api/ProductSupport/TechnicalData?language=en&region=cn&productId=1364776&mlfb=5SL6004-7"},"ai":{"faq":[{"question":"Who supplies 5SL6004-7 and how is it quoted for volume purchases?","answer":"The part is sourced through independent distribution and quoted to order against an RFQ. Availability and current pricing are confirmed at quote time."},{"question":"What is 5SL6004-7's listed depth (76 mm) on this component line?","answer":"The depth is 76 mm, with an installation depth of 70 mm."},{"question":"What is 5SL6004-7's listed width (18 mm) on this component line?","answer":"The width is 18 mm, which corresponds to 1 modular width unit."},{"question":"Will 5SL6004-7 drop into a panel that was specified around 5SL6120-7 without rewiring?","answer":"Both are 1-module-wide SENTRON MCBs on the same DIN-rail footprint, so the mechanical fit is identical. The difference is the current rating and possibly the breaking capacity — verify the branch circuit's load and fault level before substituting."},{"question":"What compliance documentation does this brand provide for 5SL6004-7 (RoHS, REACH, UL, IEC)?","answer":"The part is designed to IEC/EN 60898-1 and GB/T10963.1. It is halogen-free and silicon-free. For RoHS/REACH declarations and any UL listing, request the manufacturer's compliance documents at quote time — they are not part of this listing."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"icboms-matrix-langgraph","citationUrl":"https://aoctrl.com/siemens/5SL6004-7","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/siemens/5SL6004-7 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-08-11T15:51:03.652Z","lastPublished":"2026-08-11T15:51:03.652Z","indexable":true}}