{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"5SL6006-7","brand":"Siemens","brandSlug":"siemens","productSlug":"5SL6006-7","canonicalUrl":"https://aoctrl.com/siemens/5SL6006-7","factsUrl":"https://aoctrl.com/api/mcp/products/5SL6006-7","rawCanonicalId":null},"summary":{"shortDescription":"Siemens SENTRON 5SL6006-7, miniature circuit breaker, 1+N-pole, C-curve, 6 kA breaking capacity per IEC/EN 60898-1, 230 V AC, 1 MW wide, DIN rail mount.","salesMarkdown":"## What it is and what it does The Siemens 5SL6006-7 is a SENTRON miniature circuit breaker (MCB) in a 1+N-pole compact design, rated for 230 V AC with a C-curve tripping characteristic and a 6 kA breaking capacity per IEC/EN 60898-1. It occupies a single modular width (18 mm) on a DIN rail, making it a direct fit for residential and light commercial distribution boards where neutral switching is required. ## Key ratings and what they mean for your panel The C-curve means the breaker trips at 5–10× rated current, suited for loads with moderate inrush like lighting banks, small motors, and general-purpose circuits. The 6 kA breaking capacity is the maximum fault current it can safely interrupt at 230 V AC — adequate for most residential and light commercial installations, but verify your prospective short-circuit current (PSCC) at the point of installation. Rated insulation voltage is 250 V AC, and the operating voltage range is 50/60 Hz. The breaker is rated for overvoltage category III and pollution degree 2, which is standard for fixed-installation distribution panels. It is sealable, halogen-free, and silicon-free — relevant for installations in sensitive environments like healthcare or food processing where outgassing must be controlled. The IP20 rating applies with conductors connected, meaning it is touch-safe in a closed panel but not protected against water ingress. Operating temperature range spans -40 °C to 75 °C, so it can be installed in unconditioned enclosures or outdoor-rated cabinets without derating for cold starts. ## Mounting and integration Snaps onto a standard DIN rail in any mounting position. At 18 mm wide — one modular unit — it fits tightly in a multi-row distribution board. Installation depth is 70 mm, overall depth 76 mm, height 90 mm. The neutral conductor is switched internally, so no separate neutral bar connection is needed for the outgoing circuit. Supplementary devices (auxiliary contacts, shunt trips, undervoltage releases) can be added without replacing the breaker — useful for remote tripping or status feedback in a BMS.","metaTitle":"Siemens 5SL6006-7 SENTRON MCB, 1+N-pole C6, 6 kA, 230 V AC","metaDescription":"Siemens 5SL6006-7 SENTRON miniature circuit breaker, 1+N-pole, C-curve, 6 kA per IEC/EN 60898-1, 230 V AC, 1 MW wide, DIN rail mount. Current production.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":["1-Pole MCB (DIN Rail)"],"specifications":{"Depth":"76 mm","Width":"18 mm","title":"5SL6006-7","Height":"90 mm","Maximum":"75 °C","Minimum":"-40 °C","Sealable":"Yes","Standard":"IEC/EN60898-1, GB/T10963.1","description":"CIRCUIT BREAKER 230V 6KA, 1+N-POLE/1MW C6","Halogen-Free":"Yes","Silicon-Free":"Yes","Design Of Pole":"1P+N","lifecycle_stage":"current","Fastening Method":"DIN rail","Mounting Position":"any","at AC rated value":"230 V","at DC rated value":"60 V","Installation Depth":"70 mm","Product Brand Name":"SENTRON","Degree Of Pollution":"2","Product Designation":"Miniature circuit breaker","protection class IP":"IP20, with connected conductors","Overvoltage Category":"III","Combined Terminal Top":"No","Design Of The Product":"Miniature circuit breaker compact","Energy Limitation Class":"3","Combined Terminal Bottom":"No","Suitability For Operation":"Residential buildings/infrastructure","Neutral Conductor Switching":"Yes","Number Of Modular Width Units":"1","Position Of Power Supply Cord":"Any","Tripping Characteristic Class":"C","according to EN 60898 rated value":"6 kA","Type Of Voltage Of The Operating Voltage":"AC","insulation voltage (Ui) at AC rated value":"250 V","with single-phase operation at AC maximum":"250 V","Value Range Of The Supply Voltage Frequency":"50/60 Hz","vibration resistance according to IEC 60068-2-6":"Yes","Mechanical Service Life (Operating Cycles) Typical":"10 000","Product Extension Installable Supplementary Devices":"Yes","power loss [W] for rated value of the current at AC in hot operating state per pole":"1.4 W"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":"$9.91","stockQuantity":0,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/3b6fe2a7c12f193fa59700ee28c21649.pdf","sourceUrl":"https://support.industry.siemens.com/webbackend/api/ProductSupport/TechnicalData?language=en&region=cn&productId=1364779&mlfb=5SL6006-7"},"ai":{"faq":[{"question":"What are the key ratings of the 5SL6006-7?","answer":"C-curve trip characteristic, 6 kA breaking capacity at 230 V AC per IEC/EN 60898-1, 1+N-pole design, 1 MW wide, DIN rail mount."},{"question":"What compliance documentation is available for the 5SL6006-7?","answer":"It is certified to IEC/EN 60898-1 and GB/T 10963.1. It is halogen-free and silicon-free. The IP20 rating and overvoltage category III are documented."},{"question":"What is the physical size of the 5SL6006-7?","answer":"Width 18 mm (1 MW), height 90 mm, depth 76 mm, installation depth 70 mm."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"icboms-matrix-langgraph","citationUrl":"https://aoctrl.com/siemens/5SL6006-7","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/siemens/5SL6006-7 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-08-11T15:51:03.652Z","lastPublished":"2026-08-11T15:51:03.652Z","indexable":true}}