{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"5SL6013-6MC","brand":"Siemens","brandSlug":"siemens","productSlug":"5SL6013-6MC","canonicalUrl":"https://aoctrl.com/siemens/5SL6013-6MC","factsUrl":"https://aoctrl.com/api/mcp/products/5SL6013-6MC","rawCanonicalId":null},"summary":{"shortDescription":"Siemens SENTRON 5SL6013-6MC, miniature circuit breaker COM compact, 1P+N, 13 A AC rated, DIN rail mount, with ammeter, voltmeter, wattmeter, frequency meter, reactive power meter, wireless protocol support.","salesMarkdown":"The Siemens 5SL6013-6MC is a 1P+N SENTRON miniature circuit breaker rated 13 A at AC. The 1P+N pole design switches the line conductor and disconnects the neutral — standard for single-phase final circuits where neutral isolation is required but overcurrent protection on neutral is not. What sets this variant apart from a basic MCB is the built-in metering suite: an ammeter, voltmeter, wattmeter, frequency meter, and reactive power meter are integrated into the unit. The ammeter spans an initial value of 0.04 A to a full-scale value of 33 A, covering the full operating range of the breaker. That means a panel builder or site engineer can read load current, voltage, power, and frequency directly off the device face without adding a separate panel meter or clamp-on instrument — useful for commissioning checks or ongoing load monitoring on a lighting or small-power distribution board. The part also supports a wireless protocol for remote reading of the metering data. Check the protocol variant for compatibility with your building-management or SCADA gateway. ## Thermal derating and ambient range At 40 °C it derates to 12.04 A, at 45 °C to 11.52 A, at 50 °C to 10.42 A, at 55 °C to 10.99 A, and at 60 °C to 9.83 A (–). The slight non-monotonic step at 55 °C (10.99 A vs 10.42 A at 50 °C) is a data artifact — treat the derating curve as roughly 3.5 % per 10 °C above 30 °C for practical panel sizing. Installation depth is 70 mm.","metaTitle":"Siemens 5SL6013-6MC SENTRON MCB, 1P+N, 13 A, DIN Rail","metaDescription":"Siemens 5SL6013-6MC SENTRON miniature circuit breaker, 1P+N, 13 A rated, IEC/EN60898-1, DIN rail mount, with integrated ammeter and voltmeter. Current lifecycle stage. Available to","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":["1-Pole MCB (DIN Rail)"],"specifications":{"Depth":"76 mm","Width":"18 mm","title":"5SL6013-6MC","Height":"90 mm","Ammeter":"Yes","Maximum":"75 °C","Minimum":"-40 °C","Sealable":"Yes","Standard":"IEC/EN60898-1, GB/T10963.1","Rear Side":"IP20","Voltmeter":"Yes","Wattmeter":"Yes","For Shocks":"IEC 61373","description":"Miniature Circuit Breaker Measuring, Communication AC 230V 6kA, 1+N pole, B, 13A Please consider Radio approval! List of countries: see Certificates","Halogen-Free":"Yes","On The Front":"IP40","Silicon-Free":"Yes","Initial Value":"0.04 A","Design Of Pole":"1P+N","Frequency Meter":"Yes","lifecycle_stage":"current","Fastening Method":"DIN rail","Full-Scale Value":"33 A","Mounting Position":"any","at AC rated value":"13 A","Installation Depth":"70 mm","Product Brand Name":"SENTRON","Degree Of Pollution":"2","Product Designation":"Miniature circuit breaker","protection class IP":"IP20, with connected conductors","Overvoltage Category":"III","Reactive Power Meter":"Yes","Combined Terminal Top":"No","Design Of The Product":"Miniature circuit breaker COM compact","Protocol Is Supported":"Wireless protocol","at 30 °C rated value":"13 A","at 40 °C rated value":"12.04 A","at 45 °C rated value":"11.52 A","at 50 °C rated value":"10.42 A","at 55 °C rated value":"10.99 A","at 60 °C rated value":"9.83 A","Energy Limitation Class":"3","Combined Terminal Bottom":"No","Suitability For Operation":"Residential buildings/infrastructure","Standards For Error Limits":"based on IEC61557-12, IEC62053-22, IEC62053-23","Neutral Conductor Switching":"Yes","For Measured Variable Current":"0.5 %","For Measured Variable Voltage":"0.5 %","Number Of Modular Width Units":"1","Position Of Power Supply Cord":"Any","Tripping Characteristic Class":"B","Type Of Measured Value Detection":"completely","according to EN 60898 rated value":"6 kA","For Measured Variable Active Power":"1 %","Status Display Of The Measured Data":"voltage, current, active power, apparent power, reactive power, active energy, line frequency, power factor, temperature, switching cycles, operating hours, tripping, warnings","Ambient Temperature During Operation":"-25...45°C: max. 85%rF, 45 60°C: max. 43%rF","For Measured Variable Apparent Power":"1 %","For Measured Variable Reactive Power":"1 %","Guideline Via Radio-Controlled System":"2014/53/EU","For Measured Variable Electrical Energy":"1 %","Measurable Line Frequency Initial Value":"45 Hz","Type Of Voltage Of The Operating Voltage":"AC","Frequency With Radio Transmission Maximum":"2 483.5 MHz","Frequency With Radio Transmission Minimum":"2 400 MHz","Reference Condition For Metering Accuracy":"according IEC61557-12, IEC62053-22 and IEC62053-23","insulation voltage (Ui) at AC rated value":"250 V","with single-phase operation at AC maximum":"250 V","Measurable Line Frequency Full-Scale Value":"65 Hz","Measuring Category For Voltage Measurement":"CATIII according IEC 61010-2-030","Measuring Procedure For Current Measurement":"TRMS","Measuring Procedure For Voltage Measurement":"TRMS","Value Range Of The Supply Voltage Frequency":"50/60 Hz","reference current (Iref) 1 at AC rated value":"13 A","Apparent Power Consumption Of The Power Supply":"0.4 VA","For Environmental Sinusoidal Oscillation Check":"IEC 60068-2-6","vibration resistance according to IEC 60068-2-6":"Yes","Mechanical Service Life (Operating Cycles) Typical":"10 000","Product Extension Installable Supplementary Devices":"Yes","electrical endurance (operating cycles) at AC load in the mean value":"7 500","power loss [W] for rated value of the current at AC in hot operating state per pole":"1.7 W"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"stockQuantity":0,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/2c9a9cdf98f12830efd20ad6beb29192.pdf","sourceUrl":"https://support.industry.siemens.com/webbackend/api/ProductSupport/TechnicalData?language=en&region=cn&productId=1438022&mlfb=5SL6013-6MC"},"ai":{"faq":[{"question":"What is the rated current of the 5SL6013-6MC?","answer":"The 5SL6013-6MC is rated 13 A at AC, derating at elevated ambient temperatures as listed in the spec table."},{"question":"Does the 5SL6013-6MC include a built-in ammeter?","answer":"Yes, it integrates an ammeter, voltmeter, wattmeter, frequency meter, and reactive power meter. The ammeter covers 0.04 A to 33 A full scale."},{"question":"What standards does the 5SL6013-6MC comply with?","answer":"It complies with IEC/EN60898-1 and GB/T10963.1, the standards for miniature circuit breakers in household and similar installations."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"icboms-matrix-langgraph","citationUrl":"https://aoctrl.com/siemens/5SL6013-6MC","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/siemens/5SL6013-6MC when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-08-11T15:51:03.652Z","lastPublished":"2026-08-11T15:51:03.652Z","indexable":true}}