{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"5SL6016-6","brand":"Siemens","brandSlug":"siemens","productSlug":"5SL6016-6","canonicalUrl":"https://aoctrl.com/siemens/5SL6016-6","factsUrl":"https://aoctrl.com/api/mcp/products/5SL6016-6","rawCanonicalId":null},"summary":{"shortDescription":"Siemens SENTRON 5SL6016-6 miniature circuit breaker, 1P+N, B-curve 16 A, 6 kA breaking capacity per IEC/EN 60898-1, 1 MW width, DIN rail mount.","salesMarkdown":"The 1P+N design switches both phase and neutral, with the neutral pole opening and closing with the line pole. ## DIN-rail fit and panel space Depth is 76 mm (70 mm installation depth), height 90 mm — dimensions that match the SENTRON 5SL family footprint exactly, so it drops into an existing populated rail without re-spacing. ## B-curve — what it means on the line B-curve (3–5× In magnetic trip) means the 5SL6016-6 trips instantaneously between 48 A and 80 A. That's fast enough to protect wiring in circuits with minimal inrush — lighting, resistive heaters, control transformers — but too sensitive for motor or compressor starting. Rated voltage 230 V AC (250 V max single-phase), frequency 50/60 Hz. Halogen-free and silicon-free construction. Mechanical service life 10 000 operating cycles typical. Sealable with a locking facility for isolation lockout. Vibration-resistant per IEC 60068-2-6.","metaTitle":"Siemens 5SL6016-6 SENTRON MCB, 1P+N, B16, 6kA, 1MW","metaDescription":"Siemens 5SL6016-6 SENTRON miniature circuit breaker, 1P+N, B-curve 16 A, 6 kA per IEC/EN 60898-1. 1 MW wide, DIN rail mount. Available to order; confirm price and lead time via RFQ","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":["1-Pole MCB (DIN Rail)"],"specifications":{"Depth":"76 mm","Width":"18 mm","title":"5SL6016-6","Height":"90 mm","Maximum":"75 °C","Minimum":"-40 °C","Sealable":"Yes","Standard":"IEC/EN60898-1, GB/T10963.1","description":"CIRCUIT BREAKER 230V 6KA, 1+N-POLE/1MW B16","Halogen-Free":"Yes","Silicon-Free":"Yes","Design Of Pole":"1P+N","lifecycle_stage":"current","Fastening Method":"DIN rail","Mounting Position":"any","at AC rated value":"230 V","at DC rated value":"60 V","Installation Depth":"70 mm","Product Brand Name":"SENTRON","Degree Of Pollution":"2","Product Designation":"Miniature circuit breaker","protection class IP":"IP20, with connected conductors","Overvoltage Category":"III","Combined Terminal Top":"No","Design Of The Product":"Miniature circuit breaker compact","Energy Limitation Class":"3","Combined Terminal Bottom":"No","Suitability For Operation":"Residential buildings/infrastructure","Neutral Conductor Switching":"Yes","Number Of Modular Width Units":"1","Position Of Power Supply Cord":"Any","Tripping Characteristic Class":"B","according to EN 60898 rated value":"6 kA","Type Of Voltage Of The Operating Voltage":"AC","insulation voltage (Ui) at AC rated value":"250 V","with single-phase operation at AC maximum":"250 V","Value Range Of The Supply Voltage Frequency":"50/60 Hz","vibration resistance according to IEC 60068-2-6":"Yes","Mechanical Service Life (Operating Cycles) Typical":"10 000","Product Extension Installable Supplementary Devices":"Yes","power loss [W] for rated value of the current at AC in hot operating state per pole":"2.3 W"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"stockQuantity":0,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/2c9a9cdf98f12830efd20ad6beb29192.pdf","sourceUrl":"https://support.industry.siemens.com/webbackend/api/ProductSupport/TechnicalData?language=en&region=cn&productId=1364789&mlfb=5SL6016-6"},"ai":{"faq":[{"question":"Where can I buy 5SL6016-6 and get a price?","answer":"Sourced and quoted to order through independent distribution against an RFQ. Availability and current pricing are confirmed at quote time — submit an RFQ for your quantity and delivery location."},{"question":"What is the depth of 5SL6016-6?","answer":"Listed depth is 76 mm; installation depth is 70 mm. Width is 18 mm (1 MW), height 90 mm."},{"question":"Will 5SL6016-6 drop into a panel specified for 5SL6120-7?","answer":"Yes — both are 1 MW wide SENTRON 5SL breakers on the same DIN-rail footprint. The 5SL6120-7 is a C-curve 20 A unit; the 5SL6016-6 is B-curve 16 A. Same mechanical dimensions, same busbar pitch, same accessory compatibility. No rewiring needed if the rating and curve suit the circuit."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"icboms-matrix-langgraph","citationUrl":"https://aoctrl.com/siemens/5SL6016-6","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/siemens/5SL6016-6 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-08-11T15:51:03.652Z","lastPublished":"2026-08-11T15:51:03.652Z","indexable":true}}