{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"5SL6016-7MC","brand":"Siemens","brandSlug":"siemens","productSlug":"5SL6016-7MC","canonicalUrl":"https://aoctrl.com/siemens/5SL6016-7MC","factsUrl":"https://aoctrl.com/api/mcp/products/5SL6016-7MC","rawCanonicalId":null},"summary":{"shortDescription":"Siemens SENTRON 5SL6016-7MC, COM compact miniature circuit breaker, 1P+N, 16 A rated, DIN-rail mount, 18 mm width, 76 mm depth, IP20/IP40, current lifecycle.","salesMarkdown":"## SENTRON COM compact MCB with integrated metering The Siemens SENTRON 5SL6016-7MC is a COM compact miniature circuit breaker (MCB) in a 1P+N pole design, rated at 16 A AC and compliant with IEC/EN60898-1 and GB/T10963.1. It snaps onto a DIN rail (fastening method per) and occupies an 18 mm width — one standard module — with a 76 mm depth and 90 mm height, so it fits tight sub-distribution boards where every millimeter counts. ## What the 16 A rating means in practice The 16 A rating holds at 30 °C ambient; above that, the thermal-magnetic trip derates — 15.06 A at 40 °C, 14.57 A at 45 °C, 13.53 A at 50 °C, 14.06 A at 55 °C, and 12.98 A at 60 °C. If your panel runs hot (enclosed busway, adjacent loads), size the branch circuit for the derated value at your actual ambient, not the 30 °C nameplate. ## Built-in metering — ammeter, voltmeter, wattmeter, frequency, reactive power This COM compact variant integrates an ammeter (0.04 A initial value, 33 A full-scale), voltmeter, wattmeter, frequency meter, and reactive power meter — all in the same 18 mm footprint.","metaTitle":"Siemens SENTRON 5SL6016-7MC MCB COM compact, 16 A, 1P+N, DIN","metaDescription":"Siemens SENTRON 5SL6016-7MC miniature circuit breaker, 16 A rated, 1P+N, DIN-rail mount, IEC/EN60898-1. Current lifecycle stage, sourced to order against RFQ.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":["1-Pole MCB (DIN Rail)"],"specifications":{"Depth":"76 mm","Width":"18 mm","title":"5SL6016-7MC","Height":"90 mm","Ammeter":"Yes","Maximum":"75 °C","Minimum":"-40 °C","Sealable":"Yes","Standard":"IEC/EN60898-1, GB/T10963.1","Rear Side":"IP20","Voltmeter":"Yes","Wattmeter":"Yes","For Shocks":"IEC 61373","description":"Miniature Circuit Breaker Measuring, Communication AC 230V 6kA, 1+N pole, C, 16A Please consider Radio approval! List of countries: see Certificates","Halogen-Free":"Yes","On The Front":"IP40","Silicon-Free":"Yes","Initial Value":"0.04 A","Design Of Pole":"1P+N","Frequency Meter":"Yes","lifecycle_stage":"current","Fastening Method":"DIN rail","Full-Scale Value":"33 A","Mounting Position":"any","at AC rated value":"16 A","Installation Depth":"70 mm","Product Brand Name":"SENTRON","Degree Of Pollution":"2","Product Designation":"Miniature circuit breaker","protection class IP":"IP20, with connected conductors","Overvoltage Category":"III","Reactive Power Meter":"Yes","Combined Terminal Top":"No","Design Of The Product":"Miniature circuit breaker COM compact","Protocol Is Supported":"Wireless protocol","at 30 °C rated value":"16 A","at 40 °C rated value":"15.06 A","at 45 °C rated value":"14.57 A","at 50 °C rated value":"13.53 A","at 55 °C rated value":"14.06 A","at 60 °C rated value":"12.98 A","Energy Limitation Class":"3","Combined Terminal Bottom":"No","Suitability For Operation":"Residential buildings/infrastructure","Standards For Error Limits":"based on IEC61557-12, IEC62053-22, IEC62053-23","Neutral Conductor Switching":"Yes","For Measured Variable Current":"0.5 %","For Measured Variable Voltage":"0.5 %","Number Of Modular Width Units":"1","Position Of Power Supply Cord":"Any","Tripping Characteristic Class":"C","Type Of Measured Value Detection":"completely","according to EN 60898 rated value":"6 kA","For Measured Variable Active Power":"1 %","Status Display Of The Measured Data":"voltage, current, active power, apparent power, reactive power, active energy, line frequency, power factor, temperature, switching cycles, operating hours, tripping, warnings","Ambient Temperature During Operation":"-25...45°C: max. 85%rF, 45 60°C: max. 43%rF","For Measured Variable Apparent Power":"1 %","For Measured Variable Reactive Power":"1 %","Guideline Via Radio-Controlled System":"2014/53/EU","For Measured Variable Electrical Energy":"1 %","Measurable Line Frequency Initial Value":"45 Hz","Type Of Voltage Of The Operating Voltage":"AC","Frequency With Radio Transmission Maximum":"2 483.5 MHz","Frequency With Radio Transmission Minimum":"2 400 MHz","Reference Condition For Metering Accuracy":"according IEC61557-12, IEC62053-22 and IEC62053-23","insulation voltage (Ui) at AC rated value":"250 V","with single-phase operation at AC maximum":"250 V","Measurable Line Frequency Full-Scale Value":"65 Hz","Measuring Category For Voltage Measurement":"CATIII according IEC 61010-2-030","Measuring Procedure For Current Measurement":"TRMS","Measuring Procedure For Voltage Measurement":"TRMS","Value Range Of The Supply Voltage Frequency":"50/60 Hz","reference current (Iref) 1 at AC rated value":"16 A","Apparent Power Consumption Of The Power Supply":"0.4 VA","For Environmental Sinusoidal Oscillation Check":"IEC 60068-2-6","vibration resistance according to IEC 60068-2-6":"Yes","Mechanical Service Life (Operating Cycles) Typical":"10 000","Product Extension Installable Supplementary Devices":"Yes","electrical endurance (operating cycles) at AC load in the mean value":"7 500","power loss [W] for rated value of the current at AC in hot operating state per pole":"2.1 W"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"stockQuantity":0,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/2c9a9cdf98f12830efd20ad6beb29192.pdf","sourceUrl":"https://support.industry.siemens.com/webbackend/api/ProductSupport/TechnicalData?language=en&region=cn&productId=1438025&mlfb=5SL6016-7MC"},"ai":{"faq":[{"question":"What is 5SL6016-7MC's width and depth for panel layout?","answer":"The width is 18 mm (one standard DIN module) and the depth is 76 mm, with a 70 mm installation depth behind the panel face. Height is 90 mm."},{"question":"What compliance documentation does 5SL6016-7MC carry?","answer":"It complies with IEC/EN60898-1 and GB/T10963.1. It is halogen-free and silicon-free, and rated for shock per IEC 61373. The evidence does not list UL, CSA, or RoHS certification — verify with the manufacturer if those are required for your jurisdiction."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"icboms-matrix-langgraph","citationUrl":"https://aoctrl.com/siemens/5SL6016-7MC","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/siemens/5SL6016-7MC when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-08-11T15:51:03.652Z","lastPublished":"2026-08-11T15:51:03.652Z","indexable":true}}