{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"5SL6110-8CC","brand":"Siemens","brandSlug":"siemens","productSlug":"5SL6110-8CC","canonicalUrl":"https://aoctrl.com/siemens/5SL6110-8CC","factsUrl":"https://aoctrl.com/api/mcp/products/5SL6110-8CC","rawCanonicalId":null},"summary":{"shortDescription":"Siemens SENTRON 5SL6110-8CC, miniature circuit breaker, 1-pole, D-curve, 10 A, 6 kA per EN 60898, 400 V AC, 1 width unit.","salesMarkdown":"## What it is and what it does The Siemens 5SL6110-8CC is a 1-pole miniature circuit breaker from the SENTRON 5SL series, rated 10 A with a D tripping characteristic. It breaks fault currents up to 6 kA per EN 60898 at 230/400 V AC, single- or multi-phase. The D-curve means it tolerates high inrush currents — think motor starts, transformer energization, or capacitive loads — without nuisance tripping, while still clearing a hard short fast. ## Where it fits and how it mounts Snaps onto a standard DIN rail, one width unit (18 mm). Depth is 76 mm, installation depth 70 mm — leaves clearance for wiring behind the panel door. Mounting position any, so it works upright, sideways, or inverted inside a crowded enclosure. Rated IP20 with connected conductors, so it's intended for dry indoor panels, not washdown zones. ## What the ratings mean for your panel Rated 10 A at 400 V AC, 50 Hz. The D-curve's magnetic trip threshold is 10–20× In (100–200 A), so it's sized for loads with a high starting surge — small motors, solenoid banks, or power supplies with large input caps. The 6 kA breaking capacity per EN 60898 is the standard domestic/commercial fault level; if your available fault current exceeds that, you need an upstream current-limiting device or a higher-rated breaker. Overvoltage category III and pollution degree 2 suit fixed installations inside a building's distribution board. Sealable terminals let you lock the setting after commissioning — useful for tenant or process areas where you don't want the breaker switched off casually.","metaTitle":"Siemens 5SL6110-8CC SENTRON MCB, 1P D 10A 6kA","metaDescription":"Siemens SENTRON 5SL6110-8CC miniature circuit breaker, 1-pole D-curve 10A, 6kA breaking capacity per EN 60898, 400V AC. Current lifecycle. Sourced to order.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":["1-Pole MCB (DIN Rail)"],"specifications":{"Depth":"76 mm","Width":"18 mm","Height":"90 mm","Maximum":"75 °C","Minimum":"-40 °C","Sealable":"Yes","Rated Value":"50 Hz","Halogen-Free":"Yes","Silicon-Free":"Yes","Number Of Poles":"1","Type Of Voltage":"AC","lifecycle_stage":"current","Mounting Position":"any","Installation Depth":"70 mm","Product Brand Name":"SENTRON","Degree Of Pollution":"2","Product Designation":"Miniature circuit breaker","protection class IP":"IP20, with connected conductors","Overvoltage Category":"3","Design Of The Product":"5SL miniature circuit breakers","Number Of Width Units":"1","Number Of Poles / Note":"1P","acc. to DIN EN 61346-2":"F","acc. to DIN EN 81346-2":"F","circuit-breaker / Design":"5SL6CC","Suitability For Operation":"Residential buildings/infrastructure","Tripping Characteristic Class":"D","at DC / rated value / maximum":"72 V","acc. to EN 60898 / rated value":"6 kA","Product Feature / Touch Protection":"Yes","supply voltage / at AC / rated value":"400 V","operating current / at AC / rated value":"10 A","Influence Of The Surrounding Temperature":"Periodically +55°C, max. 95% humidity","vibration resistance / acc. to IEC 60068-2-6":"50 m/s² at 25 to 150 Hz","with multi-phase operation / at AC / maximum":"440 V","Product Function / Neutral Conductor Switching":"No","with multi-phase operation / at AC / rated value":"440 V","with single-phase operation / at AC / rated value":"250 V"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/448c45311fe75ee70c38c3b99456851d.pdf","sourceUrl":"https://support.industry.siemens.com/webbackend/api/ProductSupport/TechnicalData?language=en&region=cn&productId=198190&mlfb=5SL6110-8CC","alternativesUrl":"https://aoctrl.com/api/mcp/products/5SL6110-8CC/alternatives.json"},"ai":{"faq":[{"question":"How do I get current pricing and availability for 5SL6110-8CC?","answer":"We source and quote this part to order against an RFQ; availability and current pricing are confirmed at quote time."},{"question":"What is the breaking capacity of 5SL6110-8CC?","answer":"6 kA per EN 60898 at 230/400 V AC."},{"question":"What does the D-curve mean on this breaker?","answer":"The D tripping characteristic has a magnetic trip threshold of 10–20× In (100–200 A), so it's designed for loads with high inrush current like small motors or transformers."},{"question":"Will 5SL6110-8CC drop into a panel specified around 5SL6016-7KL without rewiring?","answer":"Both are 1-pole SENTRON 5SL breakers on the same DIN-rail footprint (18 mm width, 76 mm depth), so the mechanical fit is identical. The difference is the rating and curve — 5SL6016-7KL is a 16 A B-curve; this is a 10 A D-curve. If the circuit is designed for 10 A D-curve protection, it drops in; if the original spec called for 16 A B-curve, you'd need to verify the load and coordination."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/siemens/5SL6110-8CC","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/siemens/5SL6110-8CC when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}