{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"5SL6120-6BB","brand":"Siemens","brandSlug":"siemens","productSlug":"5SL6120-6BB","canonicalUrl":"https://aoctrl.com/siemens/5SL6120-6BB","factsUrl":"https://aoctrl.com/api/mcp/products/5SL6120-6BB","rawCanonicalId":null},"summary":{"shortDescription":"Siemens SENTRON 5SL6 series, miniature circuit breaker, 5SL6120-6BB, 1-pole, B-curve, 20 A rated, 6 kA breaking capacity per EN 60898, 400 V AC, 18 mm width.","salesMarkdown":"The Siemens SENTRON 5SL6120-6BB is a 1-pole miniature circuit breaker rated 20 A with a B-curve tripping characteristic, designed for protecting final circuits in residential buildings and infrastructure installations. It breaks fault currents up to 6 kA per EN 60898 and IEC 60947-2, which covers the typical prospective short-circuit current at the service entrance of most residential and light commercial panels. The 18 mm width (one modular unit) drops into any standard DIN-rail enclosure without needing to shuffle adjacent breakers — a straight swap for a failed or undersized 20 A B-curve unit. The B-curve means the magnetic trip activates at 3 to 5 times rated current (60–100 A for this 20 A unit), making it suitable for resistive and lighting loads with modest inrush — think general-purpose sockets, lighting circuits, and small appliances. The 6 kA breaking capacity is the maximum fault current the breaker can safely interrupt at its rated voltage; at 400 V AC this is adequate for most residential and light commercial service entrances, but verify against the available fault current at the point of installation — if your panel's SCCR exceeds 6 kA, you need a higher-rated upstream device or a current-limiting breaker. ## Panel Integration — DIN Rail and Wiring Notes The 18 mm width occupies one modular unit, and the 70 mm installation depth leaves clearance behind a standard 80 mm deep enclosure. Spring-cage terminals accept 0.2–2.5 mm² solid or ferruled stranded wire; strip length is 8 mm. The breaker is sealable for tamper-proof applications, and the halogen-free, silicon-free construction suits installations where outgassing during a fault must be minimized.","metaTitle":"Siemens 5SL6120-6BB SENTRON MCB, 20 A, B-Curve, 1P, 6 kA","metaDescription":"Siemens SENTRON 5SL6120-6BB miniature circuit breaker, 20 A rated, B-curve, 1-pole, 6 kA breaking capacity per EN 60898. Current lifecycle stage, sourced to order via RFQ.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":null,"categoryPath":[],"specifications":{"Depth":"76 mm","Poles":"1","Width":"18 mm","Height":"90 mm","IP Rating":"IP20","Product Status":"Active"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/e5562d13cec3f78d16b1ae750ea4f1d0.pdf","sourceUrl":"https://support.industry.siemens.com/webbackend/api/ProductSupport/TechnicalData?language=en&region=cn&productId=319810&mlfb=5SL6120-6BB","alternativesUrl":"https://aoctrl.com/api/mcp/products/5SL6120-6BB/alternatives.json"},"ai":{"faq":[],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/siemens/5SL6120-6BB","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/siemens/5SL6120-6BB when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}