{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"5SL6132-6RC","brand":"Siemens","brandSlug":"siemens","productSlug":"5SL6132-6RC","canonicalUrl":"https://aoctrl.com/siemens/5SL6132-6RC","factsUrl":"https://aoctrl.com/api/mcp/products/5SL6132-6RC","rawCanonicalId":null},"summary":{"shortDescription":"Siemens SENTRON 5SL6132-6RC, miniature circuit breaker, 1-pole, B characteristic, 32 A, 7.5 kA breaking capacity per EN 60898, 415 V AC, 1 MW unit, IP20.","salesMarkdown":"The Siemens SENTRON 5SL6132-6RC is a 1-pole miniature circuit breaker rated 32 A at AC with a B tripping characteristic and 7.5 kA breaking capacity per EN 60898. Rated for 415 V AC supply voltage (250 V single-phase), it handles residential and light-commercial branch circuits where the B curve provides fast magnetic trip on moderate inrush — think lighting, general-purpose receptacles, and small resistive loads. That matches typical domestic and small-commercial service-entrance ratings; if your available fault current exceeds 7.5 kA, step up to the 10 kA variant in the same SENTRON family. B-curve trip: magnetic release between 3× and 5× In (96–160 A for this 32 A unit). That's faster than a C curve on moderate surges, so it's a good fit for circuits without heavy motor or transformer inrush — keeps nuisance trips off the line.","metaTitle":"5SL6132-6RC SENTRON MCB 32A 1P B Curve 7.5kA","metaDescription":"Siemens SENTRON 5SL6132-6RC miniature circuit breaker, 32 A, 1-pole, B characteristic, 7.5 kA breaking capacity per EN 60898. Active production. Sourced to order.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":["1-Pole MCB (DIN Rail)"],"specifications":{"Depth":"76 mm","Width":"18 mm","Height":"90 mm","Maximum":"75 °C","Minimum":"-40 °C","Sealable":"Yes","Halogen-Free":"Yes","Silicon-Free":"Yes","Design Of Pole":"1P","Number Of Poles":"1","lifecycle_stage":"current","Mounting Position":"any","Installation Depth":"70 mm","Product Brand Name":"SENTRON","Degree Of Pollution":"2","Product Designation":"Miniature circuit breaker","acc. to IEC 81346-2":"F","at AC / rated value":"32 A","protection class IP":"IP20, with connected conductors","Overvoltage Category":"III","acc. to DIN EN 61346-2":"F","Energy Limitation Class":"No","at 30 °C / rated value":"32 A","Suitability For Operation":"Residential buildings/infrastructure","Number Of Modular Width Units":"1","Tripping Characteristic Class":"B","at DC / rated value / maximum":"72 V","acc. to EN 60898 / rated value":"7.5 kA","Product Feature / Touch Protection":"Yes","supply voltage / at AC / rated value":"415 V","Type Of Voltage / Of The Operating Voltage":"AC","with multi-phase operation / at AC / maximum":"440 V","Product Component / Neutral Conductor Switching":"No","with multi-phase operation / at AC / rated value":"440 V","with single-phase operation / at AC / rated value":"250 V","Mechanical Service Life (Switching Cycles) / Typical":"10 000"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":null,"sourceUrl":"https://support.industry.siemens.com/webbackend/api/ProductSupport/TechnicalData?language=en&region=cn&productId=384886&mlfb=5SL6132-6RC","alternativesUrl":"https://aoctrl.com/api/mcp/products/5SL6132-6RC/alternatives.json"},"ai":{"faq":[{"question":"Where can I buy 5SL6132-6RC and get a price?","answer":"The 5SL6132-6RC is sourced and quoted to order against an RFQ through independent distribution. Availability and current pricing are confirmed at quote time."},{"question":"Will 5SL6132-6RC drop into a panel specified around 5SL4120-7CC without rewiring?","answer":"Yes, both share the same 18 mm width, 76 mm depth, and DIN-rail mounting, so the 5SL6132-6RC fits the same panel footprint. The key difference is the tripping curve (B vs C) and breaking capacity (7.5 kA vs 10 kA), so verify the circuit's fault current and load type before swapping."},{"question":"What is the 5SL6132-6RC's depth?","answer":"The 5SL6132-6RC has a depth of 76 mm, which fits standard DIN-rail enclosures with typical 80 mm or greater internal depth."},{"question":"What compliance documentation does this brand provide for 5SL6132-6RC?","answer":"The 5SL6132-6RC is a Siemens SENTRON product certified per EN 60898 (breaking capacity 7.5 kA). It carries IP20 protection class with connected conductors and is rated for overvoltage category III, pollution degree 2. Standard documentation includes the manufacturer's declaration of conformity covering the applicable IEC/EN standards."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/siemens/5SL6132-6RC","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/siemens/5SL6132-6RC when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}