{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"5SL6206-7CC","brand":"Siemens","brandSlug":"siemens","productSlug":"5SL6206-7CC","canonicalUrl":"https://aoctrl.com/siemens/5SL6206-7CC","factsUrl":"https://aoctrl.com/api/mcp/products/5SL6206-7CC","rawCanonicalId":null},"summary":{"shortDescription":"Siemens SENTRON 5SL6 series, miniature circuit breaker, 2-pole, C-curve, 6 A, 400 V AC, 6 kA per EN 60898, 2 MWU, IP20.","salesMarkdown":"The Siemens 5SL6206-7CC is a SENTRON miniature circuit breaker — a 2-pole, C-curve unit rated 6 A at 400 V AC, with a breaking capacity of 6 kA per EN 60898. The 5SL6206-7CC occupies 2 modular width units (36 mm) on a DIN rail, with a depth of 76 mm and an installation depth of 70 mm behind the panel face. That 36 mm footprint is standard for a 2-pole MCB — it clips into the same rail as any other SENTRON 5SL6 device, so a panel layout using 1-pole or 3-pole siblings can accommodate this unit without re-spacing. The IP20 rating applies with connected conductors, meaning the busbar and wiring must be enclosed behind a distribution board cover or cabinet door. Mounting position is unrestricted, which helps when the panel is oriented for cable entry from below or above. ## What the 2-pole C-curve 6 A configuration covers The C-curve at 6 A suits general-purpose branch circuits feeding lighting, socket outlets, or small appliances in residential buildings and infrastructure.","metaTitle":"Siemens 5SL6206-7CC SENTRON MCB, 2-pole C-curve 6A 400V","metaDescription":"Siemens 5SL6206-7CC SENTRON miniature circuit breaker, 2-pole, C-curve, 6A, 400V AC, 6kA per EN 60898. Active production. Quoted to order.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":["2-Pole MCB (DIN Rail)"],"specifications":{"Depth":"76 mm","Width":"36 mm","title":"5SL6206-7CC","Height":"90 mm","Maximum":"75 °C","Minimum":"-40 °C","Sealable":"Yes","description":"Miniature circuit breaker 400 V 6kA, 2-pole, C, 6A Circuit breaker 400 V 6kA, 2-pole, C, 6A","Halogen-Free":"Yes","Silicon-Free":"Yes","Design Of Pole":"2P","Number Of Poles":"2","lifecycle_stage":"current","Mounting Position":"any","Installation Depth":"70 mm","Product Brand Name":"SENTRON","Degree Of Pollution":"2","Product Designation":"Miniature circuit breaker","protection class IP":"IP20, with connected conductors","Overvoltage Category":"III","Energy Limitation Class":"3","Suitability For Operation":"Residential buildings/infrastructure","at DC rated value maximum":"72 V","Number Of Modular Width Units":"2","Tripping Characteristic Class":"C","supply voltage at AC rated value":"400 V","according to EN 60898 rated value":"6 kA","Type Of Voltage Of The Operating Voltage":"AC","with multi-phase operation at AC maximum":"440 V","Value Range Of The Supply Voltage Frequency":"50/60 Hz","with multi-phase operation at AC rated value":"440 V","vibration resistance according to IEC 60068-2-6":"50 m/s² at 25 to 150 Hz","Product Extension Installable Supplementary Devices":"Yes","power loss [W] for rated value of the current at AC in hot operating state per pole":"1.1 W"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"stockQuantity":0,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/11ee2dc4c1cacb91e4cc204c5ea1e4d7.pdf","sourceUrl":"https://support.industry.siemens.com/webbackend/api/ProductSupport/TechnicalData?language=en&region=cn&productId=343641&mlfb=5SL6206-7CC"},"ai":{"faq":[{"question":"Where can I buy the 5SL6206-7CC and get a price?","answer":"The 5SL6206-7CC is sourced and quoted to order against an RFQ through independent distribution. Availability and current pricing are confirmed at quote time."},{"question":"What is the difference between the 5SL6206-7CC and the 5SL4363-7?","answer":"The 5SL4363-7 is a 3-pole, 63 A C-curve MCB rated 10 kA per EN 60898, with a 54 mm width (3 MWU) and 5 W power loss per pole. The 5SL6206-7CC is a 2-pole, 6 A unit at 6 kA, 36 mm wide, with 1.1 W per pole. They share the same 76 mm depth, 90 mm height, 70 mm installation depth, and SENTRON platform — but the 5SL4363-7 is a higher-current, higher-breaking-capacity device for a different branch circuit. They are not drop-in substitutes; the panel layout and conductor sizing must match the respective ratings."},{"question":"What is the depth of the 5SL6206-7CC?","answer":"The 5SL6206-7CC has a depth of 76 mm, with an installation depth of 70 mm behind the panel face."},{"question":"What is the width of the 5SL6206-7CC?","answer":"The 5SL6206-7CC has a width of 36 mm, which corresponds to 2 modular width units on a DIN rail."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"icboms-matrix-langgraph","citationUrl":"https://aoctrl.com/siemens/5SL6206-7CC","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/siemens/5SL6206-7CC when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-08-11T15:51:03.652Z","lastPublished":"2026-08-11T15:51:03.652Z","indexable":true}}