{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"5SL6213-7","brand":"Siemens","brandSlug":"siemens","productSlug":"5SL6213-7","canonicalUrl":"https://aoctrl.com/siemens/5SL6213-7","factsUrl":"https://aoctrl.com/api/mcp/products/5SL6213-7","rawCanonicalId":null},"summary":{"shortDescription":"Siemens SENTRON 5SL6213-7, 2-pole miniature circuit breaker, C-curve, 13 A rated current, 6 kA breaking capacity per EN 60898 and IEC 60947-2, 400 V AC, 2 modular width units (36 mm).","salesMarkdown":"The Siemens 5SL6213-7 is a 2-pole SENTRON miniature circuit breaker rated 13 A with a C-curve trip characteristic. It breaks fault currents up to 6 kA per EN 60898 and IEC 60947-2 at 400 V AC, 50/60 Hz. That 6 kA rating is the interrupting capacity you size the downstream coordination against — it tells you the breaker can clear a bolted fault at that level without welding its contacts or rupturing the case. ## Fit and panel integration Occupies 2 modular width units (36 mm total) on a DIN rail. Depth is 76 mm, installation depth 70 mm — the extra 6 mm accounts for the front toggle throw. Mounting position is any, so it works in horizontal busbar arrangements or vertical sub-feed panels. IP20 with connected conductors, meaning it's protected against finger contact once wired but not against moisture; keep it inside a rated enclosure. Sealable design allows the installer to lock the toggle in the off position with a padlock hasp — useful for lockout/tagout on a dedicated circuit. Halogen-free and silicon-free construction matters if the panel is in a clean room or oxygen-enriched environment where outgassing could cause corrosion or contamination. ## Electrical ratings and what they mean for the circuit C-curve trips at 5 to 10 times rated current (65 to 130 A magnetic release), which is the standard choice for general-purpose distribution feeding resistive and light inductive loads — lighting, small transformers, control circuits. Not intended for motor starting inrush unless the motor FLA is well below 13 A and the starting current stays under the magnetic threshold. Rated for multi-phase operation up to 440 V AC maximum, with a pollution degree 2 and overvoltage category III — that's the typical environment for a fixed-installation distribution board where transients from upstream switching are expected. Power loss per pole is 1.9 W at rated current in hot operating state; for a 2-pole breaker that's 3.8 W total heat to dissipate inside the enclosure. Stack several of these in a row and the cumulative heat matters for the enclosure's thermal derating.","metaTitle":"Siemens 5SL6213-7 SENTRON MCB, 2P C 13A 6kA","metaDescription":"Siemens 5SL6213-7 SENTRON miniature circuit breaker, 2-pole, C-curve, 13 A, 6 kA per IEC 60898/60947-2. Active production. Sourced to order.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":[],"specifications":{"Depth":"76 mm","Poles":"2","Width":"36 mm","Height":"90 mm","IP Rating":"IP20","Product Status":"Active","Energy Limitation Class":"3"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":"$11.43","priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/a6545637ed82478e3b4e84536cbaca58.pdf","sourceUrl":"https://support.industry.siemens.com/webbackend/api/ProductSupport/TechnicalData?language=en&region=cn&productId=281065&mlfb=5SL6213-7","alternativesUrl":"https://aoctrl.com/api/mcp/products/5SL6213-7/alternatives.json"},"ai":{"faq":[],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/siemens/5SL6213-7","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/siemens/5SL6213-7 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}