{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"5SL6215-7CC","brand":"Siemens","brandSlug":"siemens","productSlug":"5SL6215-7CC","canonicalUrl":"https://aoctrl.com/siemens/5SL6215-7CC","factsUrl":"https://aoctrl.com/api/mcp/products/5SL6215-7CC","rawCanonicalId":null},"summary":{"shortDescription":"Siemens SENTRON 5SL6215-7CC miniature circuit breaker, 2-pole, C-curve, 1.6 A, 400 V AC, 6 kA breaking capacity per EN 60898, 2 MW units, IP20.","salesMarkdown":"The Siemens SENTRON 5SL6215-7CC is a 2-pole miniature circuit breaker rated 1.6 A with a C tripping characteristic, designed for 400 V AC residential and infrastructure branch circuits. At 1.6 A it covers low-current lighting strings, control transformers, or signal power supplies — not motor feeders. Mounting position is unrestricted, so horizontal or vertical busbar feeds work equally. For commercial or industrial panels where the prospective short-circuit current exceeds 6 kA, you need the 10 kA variant (5SL4363-7) or a current-limiting upstream fuse. The 1.6 A rating is low; verify your minimum fault current is above the magnetic trip threshold (8 A to 16 A for C-curve) or the breaker may not trip fast on a high-impedance fault. The -40 °C to 75 °C operating range covers unheated utility rooms and attic-mounted panels in most climates.","metaTitle":"Siemens 5SL6215-7CC SENTRON MCB, 2-Pole C-Curve 1.6A 400V 6k","metaDescription":"Siemens SENTRON 5SL6215-7CC miniature circuit breaker, 2-pole, C-curve, 1.6 A, 400 V AC, 6 kA breaking capacity per EN 60898. Active production, available to order. Request a quote","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":["2-Pole MCB (DIN Rail)"],"specifications":{"Depth":"76 mm","Width":"36 mm","Height":"90 mm","Maximum":"75 °C","Minimum":"-40 °C","Sealable":"Yes","Halogen-Free":"Yes","Silicon-Free":"Yes","Design Of Pole":"2P","Number Of Poles":"2","lifecycle_stage":"current","Mounting Position":"any","Installation Depth":"70 mm","Product Brand Name":"SENTRON","Degree Of Pollution":"2","Product Designation":"Miniature circuit breaker","protection class IP":"IP20, with connected conductors","Overvoltage Category":"III","Energy Limitation Class":"3","Suitability For Operation":"Residential buildings/infrastructure","at DC rated value maximum":"72 V","Number Of Modular Width Units":"2","Tripping Characteristic Class":"C","supply voltage at AC rated value":"400 V","according to EN 60898 rated value":"6 kA","Type Of Voltage Of The Operating Voltage":"AC","with multi-phase operation at AC maximum":"440 V","Value Range Of The Supply Voltage Frequency":"50/60 Hz","with multi-phase operation at AC rated value":"440 V","vibration resistance according to IEC 60068-2-6":"50 m/s² at 25 to 150 Hz","Product Extension Installable Supplementary Devices":"Yes","power loss [W] for rated value of the current at AC in hot operating state per pole":"1.3 W"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/a6545637ed82478e3b4e84536cbaca58.pdf","sourceUrl":"https://support.industry.siemens.com/webbackend/api/ProductSupport/TechnicalData?language=en&region=cn&productId=52315&mlfb=5SL6215-7CC","alternativesUrl":"https://aoctrl.com/api/mcp/products/5SL6215-7CC/alternatives.json"},"ai":{"faq":[{"question":"Where can I buy the 5SL6215-7CC and get a price?","answer":"The 5SL6215-7CC is sourced to order against an RFQ through our independent distribution network. Submit a request for quote (RFQ) and we will confirm current pricing and lead time at quote time."},{"question":"Will the 5SL6215-7CC drop into a panel specified around the 5SL4363-7 without rewiring?","answer":"No — the 5SL4363-7 is a 3-pole, 54 mm wide (3 MW) breaker, while the 5SL6215-7CC is 2-pole, 36 mm wide (2 MW). The depth, height, and DIN-rail mounting are identical, but the panel must have a 2-pole busbar and a 36 mm slot. The 5SL4363-7 also carries a 10 kA breaking capacity versus 6 kA on this unit, so a direct swap without checking the fault level is not recommended."},{"question":"What is the 5SL6215-7CC's depth?","answer":"The 5SL6215-7CC has a depth of 76 mm, with an installation depth of 70 mm into the DIN rail. This is standard for the SENTRON 5SL series and clears most domestic enclosures."},{"question":"What compliance documentation does Siemens provide for the 5SL6215-7CC?","answer":"Siemens provides CE declaration of conformity, RoHS and REACH compliance documentation with the shipment. The breaker is halogen-free and silicon-free per its material spec, and carries IP20 finger protection with connected conductors."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/siemens/5SL6215-7CC","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/siemens/5SL6215-7CC when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}