{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"5SL6410-6","brand":"Siemens","brandSlug":"siemens","productSlug":"5SL6410-6","canonicalUrl":"https://aoctrl.com/siemens/5SL6410-6","factsUrl":"https://aoctrl.com/api/mcp/products/5SL6410-6","rawCanonicalId":null},"summary":{"shortDescription":"Siemens SENTRON 5SL6410-6 miniature circuit breaker, 4-pole, B-curve, 10 A, 6 kA breaking capacity, 400 V AC, 4 width units.","salesMarkdown":"The Siemens SENTRON 5SL6410-6 is a 4-pole miniature circuit breaker (MCB) from the 5SL6 design family, rated 10 A at 400 V AC with a B tripping characteristic. Snap-on DIN rail mounting; the 4-pole body occupies 4 width units (72 mm wide). Conductor range 0.75 mm² to 25 mm², accepting solid or stranded copper. Mounting position is unrestricted; the design is halogen-free and silicon-free, and the enclosure is sealable. These matter for panels in clean-room or coated-board environments where outgassing or tamper evidence is specified.","metaTitle":"Siemens 5SL6410-6 SENTRON MCB, 4-pole B 10 A, 6 kA","metaDescription":"Siemens 5SL6410-6 SENTRON miniature circuit breaker, 4-pole, B-curve, 10 A, 6 kA breaking capacity per EN 60898/IEC 60947-2, 400 V AC. Active production, sourced to order — RFQ for","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":["4-Pole MCB (DIN Rail)"],"specifications":{"Depth":"76 mm","Width":"72 mm","title":"5SL6410-6","Height":"90 mm","Maximum":"25 mm²","Minimum":"0.75 mm²","Sealable":"Yes","Rated Value":"50 Hz","description":"Miniature circuit breaker 400 V 6kA, 4-pole, B, 10 A","Halogen-Free":"Yes","Silicon-Free":"Yes","Number of poles":"4","Type of voltage":"AC","lifecycle_stage":"current","Mounting position":"any","Installation depth":"70 mm","Product brand name":"SENTRON","Product designation":"Miniature circuit breaker","Protection class IP":"IP20, with connected conductors","Overvoltage category":"3","Design of the product":"5SL miniature circuit breakers","Energy limiting class":"3","Number of width units":"4","Number of poles / Note":"4P","acc. to DIN EN 61346-2":"F","acc. to DIN EN 81346-2":"F","circuit-breaker / Design":"5SL6","Suitability for operation":"Residential buildings/infrastructure","Current / at AC / rated value":"10 A","Tripping characteristic class":"B","at DC / rated value / maximum":"60 V","acc. to EN 60898 / rated value":"6 kA","acc. to IEC 60947-2 / rated value":"6 kA","Product feature / Touch protection":"Yes","Supply voltage / at AC / rated value":"400 V","Influence of the surrounding temperature":"Periodically +55°C, max. 95% humidity","with multi-phase operation / at AC / maximum":"440 V","Product function / neutral conductor switching":"No","with multi-phase operation / at AC / rated value":"440 V","Mechanical service life (switching cycles) / typical":"10 000"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"stockQuantity":0,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/7891f742c99c05f4bec13b9ca563b8c9.pdf","sourceUrl":"https://support.industry.siemens.com/webbackend/api/ProductSupport/TechnicalData?language=en&region=cn&productId=393951&mlfb=5SL6410-6"},"ai":{"faq":[{"question":"Where can I buy the 5SL6410-6 and how is it quoted?","answer":"Sourced to order against an RFQ through our independent distribution channel. Availability and current pricing are confirmed at quote time — submit an RFQ for volume or single-piece requirements."},{"question":"What is the 5SL6410-6's breaking capacity and which standard applies?","answer":"Rated breaking capacity is 6 kA per both EN 60898 and IEC 60947-2 — the same figure under both standards, so coordination studies can use either reference."},{"question":"Will the 5SL6410-6 drop into a panel specified around the 5SL4120-7CC?","answer":"Both are 4-pole SENTRON MCBs on the same DIN-rail footprint, so mechanical fit is the same. The 5SL6410-6 carries a B-curve at 10 A / 6 kA; verify that the 5SL4120-7CC's rating (not listed here) matches your branch circuit requirements before swapping."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"icboms-matrix-langgraph","citationUrl":"https://aoctrl.com/siemens/5SL6410-6","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/siemens/5SL6410-6 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-08-11T15:51:03.652Z","lastPublished":"2026-08-11T15:51:03.652Z","indexable":true}}