{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"5SL7202-7RC","brand":"Siemens","brandSlug":"siemens","productSlug":"5SL7202-7RC","canonicalUrl":"https://aoctrl.com/siemens/5SL7202-7RC","factsUrl":"https://aoctrl.com/api/mcp/products/5SL7202-7RC","rawCanonicalId":null},"summary":{"shortDescription":"Siemens Betagard miniature circuit breaker, 5SL7202-7RC, 2-pole, C-curve, 415 V AC, 15 kA (EN 60898) / 20 kA (IEC 60947-2), 2 modular width units.","salesMarkdown":"## What the ratings mean for fit The Siemens Betagard 5SL7202-7RC is a 2-pole miniature circuit breaker rated 415 V AC with a C-curve tripping characteristic. The 15 kA breaking capacity per EN 60898 covers most commercial and light industrial panelboard applications; the 20 kA rating per IEC 60947-2 gives headroom for higher-fault installations where the upstream transformer is close. The C-curve means the magnetic trip operates at 5 to 10 times rated current — standard for motor and lighting circuits where inrush is moderate. The 2-pole design switches both phase and neutral, and the 2-module-width (18 mm per pole) footprint fits standard DIN-rail enclosures. Rated for industrial environments with overvoltage category III and pollution degree 2, this MCB is suitable for fixed installations inside control panels. The IP20 rating applies with conductors connected — the breaker itself is not sealed against washdown, so it belongs inside a cabinet, not on the machine exterior. ## Integration and compliance Mounts in any position on a DIN rail. Depth is 76 mm, installation depth 70 mm — verify enclosure depth clearance if retrofitting into a shallow panel. The 18 mm width per pole (36 mm total for 2 poles) occupies two modular units. Sealable, halogen-free, and silicon-free construction suits environments where outgassing or contamination is a concern. Vibration resistant per IEC 60068-2-6, with a mechanical service life of 10 000 operating cycles typical. Power loss is 1.2 W per pole at rated current in hot operating state — negligible for thermal budgeting in a populated enclosure.","metaTitle":"Siemens Betagard 5SL7202-7RC MCB, 2-Pole C-Curve 15kA","metaDescription":"Siemens Betagard 5SL7202-7RC miniature circuit breaker, 2-pole, C-curve, 15 kA per EN 60898, 20 kA per IEC 60947-2, 415 V AC. Current production. Sourced to order.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":null,"categoryPath":["2-Pole MCB (DIN Rail)"],"specifications":{"Depth":"76 mm","Width":"18 mm","title":"5SL7202-7RC","Height":"90 mm","Maximum":"75 °C","Minimum":"-40 °C","Sealable":"Yes","description":"Miniature circuit breaker 415 V 2-pole 15 kA C 2","Halogen-Free":"Yes","Silicon-Free":"Yes","Design Of Pole":"2P","Number Of Poles":"2","lifecycle_stage":"current","Mounting Position":"any","Installation Depth":"70 mm","Product Brand Name":"Betagard","Degree Of Pollution":"2","Product Designation":"Miniature circuit breaker","protection class IP":"IP20, with connected conductors","Overvoltage Category":"III","Suitability For Operation":"Industry","Number Of Modular Width Units":"2","Tripping Characteristic Class":"C","supply voltage at AC rated value":"415 V","according to EN 60898 rated value":"15 kA","according to IEC 60947-2 rated value":"20 kA","Type Of Voltage Of The Operating Voltage":"AC","with multi-phase operation at AC maximum":"440 V","Value Range Of The Supply Voltage Frequency":"50/60 Hz","with multi-phase operation at AC rated value":"440 V","with single-phase operation at AC rated value":"440 V","vibration resistance according to IEC 60068-2-6":"yes","Mechanical Service Life (Operating Cycles) Typical":"10 000","power loss [W] for rated value of the current at AC in hot operating state per pole":"1.2 W"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"stockQuantity":0,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/970662ff9b3cf1b597e4145bb88b34d6.pdf","sourceUrl":"https://support.industry.siemens.com/webbackend/api/ProductSupport/TechnicalData?language=en&region=cn&productId=646342&mlfb=5SL7202-7RC"},"ai":{"faq":[{"question":"Where can I buy 5SL7202-7RC and get a price?","answer":"We source this part to order against an RFQ. Submit a request for quote and we will confirm availability and current pricing."},{"question":"What is the breaking capacity of 5SL7202-7RC?","answer":"15 kA per EN 60898 and 20 kA per IEC 60947-2 at 415 V AC. The higher IEC figure applies when the breaker is certified under that standard, giving additional fault-current headroom."},{"question":"Will 5SL7202-7RC drop into a panel specified around 5SL4363-7?","answer":"No, not without rewiring. The 5SL7202-7RC is a 2-pole breaker (36 mm wide, 2 modular units), while the 5SL4363-7 is a 3-pole breaker (54 mm wide, 3 modular units). The panel's DIN-rail space and the number of conductors served are different."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"icboms-matrix-langgraph","citationUrl":"https://aoctrl.com/siemens/5SL7202-7RC","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/siemens/5SL7202-7RC when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-08-11T15:51:03.652Z","lastPublished":"2026-08-11T15:51:03.652Z","indexable":true}}