{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"5SM3417-0","brand":"Siemens","brandSlug":"siemens","productSlug":"5SM3417-0","canonicalUrl":"https://aoctrl.com/siemens/5SM3417-0","factsUrl":"https://aoctrl.com/api/mcp/products/5SM3417-0","rawCanonicalId":null},"summary":{"shortDescription":"Siemens SENTRON 5SM3417-0, RCCB, 2-pole, 80 A at 40 °C, 100 mA trip, 230 V AC, instantaneous, IP20, DIN rail mount.","salesMarkdown":"The Siemens 5SM3417-0 is a SENTRON residual current circuit breaker (RCCB) rated 80 A at 40 °C, 100 mA trip sensitivity, 2-pole, 230 V AC, instantaneous type (no short-time delay). The 100 mA trip is sized for equipment protection or circuits where a higher leakage threshold is acceptable — not the 30 mA required for personal shock protection in standard socket-outlet circuits. Mounts on DIN rail (2.5 width units, 36 mm wide, 70 mm deep), IP20 with conductors connected. Snaps onto DIN rail (REG). Any mounting position works, but the IP20 rating assumes the distribution board is installed with conductors connected. Terminal accepts solid or stranded from 1.5 to 25 mm². The 70 mm depth fits standard shallow enclosures — check gland plate clearance if back-panel depth is tight. ## Thermal derating Above that, derate linearly: 75.2 A at 50 °C, 70.4 A at 55 °C, 65.6 A at 60 °C, 60.8 A at 65 °C, 56 A at 70 °C. Ambient range is -40 to +75 °C, but the derating curve governs continuous load above 45 °C. ## Compliance & approvals Overvoltage category III. Finger- and back-of-hand safe per protection against electrical shock. Silicon-free construction. I²t value 70 000 A²·s. Designed per DIN EN 61346-2 and DIN EN 81346-2 (function letter F). Operates at 50 Hz only.","metaTitle":"Siemens 5SM3417-0 SENTRON RCCB, 80 A, 100 mA, 2-pole, 230 V","metaDescription":"Siemens 5SM3417-0 SENTRON RCCB, 80 A rated, 100 mA trip, 2-pole, 230 V AC, 10 kA SCCR. Current-production lifecycle. Sourced to order against RFQ.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":null,"categoryPath":["Residual Current Breakers (RCCB/RCBO)"],"specifications":{"Depth":"70 mm","Solid":"1.5 ... 25 mm²","Width":"36 mm","Height":"90 mm","Stranded":"1.5 ... 25 mm²","at 40 Cel":"80 A","at 45 Cel":"80 A","at 50 Cel":"75.2 A","at 55 Cel":"70.4 A","at 60 Cel":"65.6 A","at 65 Cel":"60.8 A","at 70 Cel":"56 A","Rated Value":"50 Hz","Wertebereich":"-5 ... +45 °C","Mounting type":"DIN rail (REG)","Number of poles":"2","lifecycle_stage":"current","Mounting position":"any","Installation depth":"70 mm","Product brand name":"SENTRON","Ambient temperature":"-40 ... +75 °C","Operating frequency":"50Hz","Product designation":"RCCB","Protection class IP":"IP20, if the distribution board is installed, with connected conductors","Overvoltage category":"III","Design of the product":"Instantaneous","Number of width units":"2.5","Type of fault current":"AC","acc. to DIN EN 61346-2":"F","acc. to DIN EN 81346-2":"F","I2t-value / permissible":"70 000 A²·s","circuit-breaker / Design":"5SM3","Short-circuit current rating":"10 kA","Current / at AC / rated value":"80 A","Product feature / silicon-free":"Yes","Position / of power supply cord":"top or bottom","Protection against electrical shock":"Finger and back-of-hand safe","Supply voltage / at AC / rated value":"230 V","Switching function / short-term delayed":"No","Tripping residual current / rated value":"100 mA","Tightening torque / with screw-type terminals":"2.5 ... 3 N·m","Size of installation devices / acc. to DIN 43880":"1","Supply voltage / for testing equipment / minimum":"100 V","Mechanical service life (switching cycles) / typical":"10 000"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":null,"sourceUrl":"https://support.industry.siemens.com/webbackend/api/ProductSupport/TechnicalData?language=en&region=cn&productId=337362&mlfb=5SM3417-0","alternativesUrl":"https://aoctrl.com/api/mcp/products/5SM3417-0/alternatives.json"},"ai":{"faq":[{"question":"Where can I buy the 5SM3417-0?","answer":"Sourced and quoted to order against an RFQ through independent distribution. Availability and current pricing confirmed at quote time."},{"question":"What is the 5SM3417-0 used for?","answer":"It is a residual current circuit breaker (RCCB) for equipment protection or circuits where 100 mA trip sensitivity is acceptable — typically industrial panels, not personal shock protection."},{"question":"What are the key ratings of the 5SM3417-0?","answer":"80 A at 40 °C, 100 mA trip, 2-pole, 230 V AC, instantaneous, 10 kA SCCR, DIN rail mount, IP20."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/siemens/5SM3417-0","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/siemens/5SM3417-0 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}