{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"5SP3716-2KK01","brand":"Siemens","brandSlug":"siemens","productSlug":"5SP3716-2KK01","canonicalUrl":"https://aoctrl.com/siemens/5SP3716-2KK01","factsUrl":"https://aoctrl.com/api/mcp/products/5SP3716-2KK01","rawCanonicalId":null},"summary":{"shortDescription":"Siemens SENTRON 5SP3 series, miniature circuit breaker, 1-pole, 16 A, E characteristic, 25 kA breaking capacity, busbar mount.","salesMarkdown":"The Siemens 5SP3716-2KK01 is a 1-pole SENTRON miniature circuit breaker rated 16 A at 230 V AC, 50 Hz, with an E tripping characteristic and a 25 kA breaking capacity per EN 60898. It mounts on a 40-mm busbar system per DIN 43870 Part 2, which is the standard meter-panel busbar pitch in European residential and infrastructure installations. The 1.5 width units (roughly 27 mm) keep the footprint tight in a multi-pole distribution board. Infeed is via box terminal at the top; outgoing is through a spring-loaded terminal, so no screw torque is needed on the load side — just strip and push. ## Where it goes and what it protects This breaker is designed for residential buildings and infrastructure — think apartment distribution boards, light commercial sub-panels, or meter cabinets. The E characteristic is less common than B or C in general-purpose circuits, but it's specified where the load has a known high inrush that would trip a C curve on energisation: small transformers, power supplies, or capacitor banks. The enclosure depth is 76.3 mm, and the overall depth including terminals is 89.5 mm — that's the dimension to check against a shallow meter-panel lid.","metaTitle":"Siemens 5SP3716-2KK01 SENTRON MCB, 1P 16A E-Curve, 25kA","metaDescription":"Siemens 5SP3716-2KK01 SENTRON miniature circuit breaker, 1-pole, 16 A, E tripping characteristic, 25 kA breaking capacity per EN 60898. Current lifecycle stage. Sourced to order ag","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":null,"categoryPath":[],"specifications":{"Depth":"89.5 mm","Poles":"1","Height":"151.3 mm","Mounting":"Busbar","IP Rating":"IP40","Product Status":"Active","Temp Operating Max":"55 °C","Temp Operating Min":"-25 °C"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/65739c954b45ddeb7eba174bfa3dbb97.pdf","sourceUrl":"https://support.industry.siemens.com/webbackend/api/ProductSupport/TechnicalData?language=en&region=cn&productId=236101&mlfb=5SP3716-2KK01","alternativesUrl":"https://aoctrl.com/api/mcp/products/5SP3716-2KK01/alternatives.json"},"ai":{"faq":[],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/siemens/5SP3716-2KK01","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/siemens/5SP3716-2KK01 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}