{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"5SP3740-2KK02","brand":"Siemens","brandSlug":"siemens","productSlug":"5SP3740-2KK02","canonicalUrl":"https://aoctrl.com/siemens/5SP3740-2KK02","factsUrl":"https://aoctrl.com/api/mcp/products/5SP3740-2KK02","rawCanonicalId":null},"summary":{"shortDescription":"Siemens SENTRON 5SP3, miniature circuit breaker (MCB), 1-pole, 40 A, E tripping characteristic, 25 kA breaking capacity per EN 60898, busbar mount, 1.5 width units, 5SP3740-2KK02.","salesMarkdown":"The Siemens 5SP3740-2KK02 is a 1-pole miniature circuit breaker from the SENTRON 5SP3 series, rated 40 A with an E tripping characteristic and a 25 kA breaking capacity per EN 60898. It mounts on a 40-mm busbar system per DIN 43870 Part 2 and occupies 1.5 width units — a form factor designed for residential and infrastructure meter panels where the supply cord enters at the lower section of the enclosure. The E-curve trips magnetically between 10× and 20× In (400–800 A for this 40 A unit), which is higher than a B- or C-curve. That selectivity matters when you have inrush from multiple downstream loads or transformer-fed circuits — you want the branch MCB to clear a fault before the upstream device, not nuisance-trip on a motor start. The outgoing feeder uses a spring-loaded terminal; infeed is at the box terminal. That 50 mm² top end means it can handle the incoming service cable for a residential main breaker role, not just branch circuits. Protection class is IP40 with connected conductors — fine for enclosed meter panels, not for wet or outdoor locations without a weatherproof enclosure. Mechanical robustness: shock resistance is 30 g for at least 3 impacts at 11 ms duration; vibration resistance per IEC 60068-2-6 is 2 g over 20 frequency cycles from 5 to 150 Hz. The switch position indicator shows green for OFF, red for ON. ## Sealing and locking provisions The 5SP3740-2KK02 is sealable and includes a locking slide compatible with a lock, additional wire seal, cable ties, and Antilux. This is a practical detail for utility metering or tamper-evident installations where the breaker position must be locked after commissioning.","metaTitle":"Siemens 5SP3740-2KK02 SENTRON MCB, 1P 40A E-Curve, 25kA","metaDescription":"Siemens 5SP3740-2KK02 SENTRON miniature circuit breaker, 1-pole, 40 A, E tripping characteristic, 25 kA breaking capacity per EN 60898. Busbar mount, 1.5 width units. Sourced to or","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":null,"categoryPath":[],"specifications":{"Depth":"89.5 mm","Poles":"1","Height":"151.3 mm","Mounting":"Busbar","IP Rating":"IP40","Product Status":"Active","Temp Operating Max":"55 °C","Temp Operating Min":"-25 °C"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/e75a726f46c8c74252c2110689bce044.pdf","sourceUrl":"https://support.industry.siemens.com/webbackend/api/ProductSupport/TechnicalData?language=en&region=cn&productId=472958&mlfb=5SP3740-2KK02","alternativesUrl":"https://aoctrl.com/api/mcp/products/5SP3740-2KK02/alternatives.json"},"ai":{"faq":[],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/siemens/5SP3740-2KK02","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/siemens/5SP3740-2KK02 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}