{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"5SP3763-2KK01","brand":"Siemens","brandSlug":"siemens","productSlug":"5SP3763-2KK01","canonicalUrl":"https://aoctrl.com/siemens/5SP3763-2KK01","factsUrl":"https://aoctrl.com/api/mcp/products/5SP3763-2KK01","rawCanonicalId":null},"summary":{"shortDescription":"Siemens SENTRON 5SP3 series, main miniature circuit breaker (SHU), 1-pole, 63 A, E tripping characteristic, 25 kA breaking capacity, 230/400 V AC, 50 Hz, busbar mount.","salesMarkdown":"The Siemens 5SP3763-2KK01 is a SENTRON 5SP3 main miniature circuit breaker (SHU) — a 1-pole, 63 A unit with an E tripping characteristic, rated 25 kA breaking capacity per EN 60898 at 230/400 V AC, 50 Hz. It's designed for residential and infrastructure meter panels, mounting on a 40-mm busbar system per DIN 43870 Part 2. The E curve means it's tailored for feeder protection where moderate inrush tolerance is needed — think main incomers or distribution subfeeds in building installations. At 63 A, this breaker handles a substantial residential or light commercial main feed — enough for a multi-unit panel or a large single-family service. Overvoltage category IV (6 kV surge rating) confirms it's rated for the utility-side interface, not just downstream branch circuits. Insulation voltage is 690 V, giving headroom for 400 V line-to-line applications if needed. Physical fit: 89.5 mm deep, 151.3 mm high, occupying 1.5 width units on the busbar. The depth includes the enclosure at 76.3 mm plus the spring-loaded outgoing terminal. Sealable and lockable (locking slide with wire seal, cable ties, Antilux) for utility or authority sealing. ## Integration notes Mounts on a 40-mm busbar system per DIN 43870 Part 2 — standard for European meter panels. Infeed is via box terminal at the bottom (stipulated by installation in the lower section of the meter panel). Outgoing feeder uses a spring-loaded terminal, no screw torque to manage. Switch position indicator shows OFF = green, ON = red. Shock-rated to 30 g (3 impacts, 11 ms duration) and vibration-rated to 2 g per IEC 60068-2-6 — robust for transport and utility environment.","metaTitle":"Siemens 5SP3763-2KK01 SENTRON MCB, 1-pole, 63 A, E-curve, 25","metaDescription":"Siemens SENTRON 5SP3763-2KK01 main miniature circuit breaker, 1-pole, 63 A, E tripping characteristic, 25 kA breaking capacity per EN 60898. Current production. Sourced to order ag","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":null,"categoryPath":[],"specifications":{"Depth":"89.5 mm","Poles":"1","Height":"151.3 mm","Mounting":"Busbar","IP Rating":"IP40","Product Status":"Active"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/2463d900d9656879f44335096b53c77b.pdf","sourceUrl":"https://support.industry.siemens.com/webbackend/api/ProductSupport/TechnicalData?language=en&region=cn&productId=394111&mlfb=5SP3763-2KK01","alternativesUrl":"https://aoctrl.com/api/mcp/products/5SP3763-2KK01/alternatives.json"},"ai":{"faq":[],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/siemens/5SP3763-2KK01","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/siemens/5SP3763-2KK01 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}