{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"5SP3763-2KK02","brand":"Siemens","brandSlug":"siemens","productSlug":"5SP3763-2KK02","canonicalUrl":"https://aoctrl.com/siemens/5SP3763-2KK02","factsUrl":"https://aoctrl.com/api/mcp/products/5SP3763-2KK02","rawCanonicalId":null},"summary":{"shortDescription":"Siemens SENTRON 5SP3 series, 1-pole miniature circuit breaker, 63 A, E-characteristic, 25 kA breaking capacity, busbar mount, 1.5 width units.","salesMarkdown":"The Siemens SENTRON 5SP3763-2KK02 is a 1-pole miniature circuit breaker (MCB) with an E-tripping characteristic, rated 63 A at 230 V AC and 50 Hz. It's built for residential and infrastructure panels — think meter cabinets, distribution boards, and building supply circuits where you need a higher inrush tolerance than a B-curve but faster response than a D-curve. This breaker snaps onto a 40-mm busbar system per DIN 43870 Part 2 — the standard meter-panel layout in European installations. At 1.5 width units (modular), it's wider than a standard single-module MCB, so check your DIN-rail or busbar comb spacing before committing. The enclosure depth is 76.3 mm; overall depth with terminals is 89.5 mm. Infeed is at the box terminal; outgoing is via a spring-loaded terminal that accepts solid or stranded copper from 2.5 to 50 mm². ## What the E-curve and ratings mean on the job The E-tripping characteristic sits between the classic C and D curves — it allows a short-duration inrush of 10 to 20 times rated current before the magnetic trip fires. The 63 A rating carries the continuous load; the 25 kA rated short-circuit capacity (at 230 V AC) means it can safely interrupt a fault up to 25,000 amps without welding its contacts or bursting the case. ## Environmental and handling limits Shock-rated to 30 g (11 ms pulse, 3 impacts) and vibration-tested to 2 g per IEC 60068-2-6, so it'll hold up in a genset enclosure or a panel bolted to a machine skid. The switch-position indicator shows green for ON, red for OFF — no guessing when you're trying to confirm isolation.","metaTitle":"Siemens 5SP3763-2KK02 SENTRON MCB, 63 A, 1P, E-Curve, 25 kA","metaDescription":"Siemens SENTRON 5SP3763-2KK02 miniature circuit breaker, 1-pole, 63 A rated current, E-tripping characteristic, 25 kA breaking capacity at 230 V AC. Active production. Quoted to or","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":null,"categoryPath":[],"specifications":{"Depth":"89.5 mm","Poles":"1","Height":"151.3 mm","Mounting":"Busbar","IP Rating":"IP40","Product Status":"Active","Temp Operating Max":"55 °C","Temp Operating Min":"-25 °C"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/69b5d51c694fa5f13783046d2688e872.pdf","sourceUrl":"https://support.industry.siemens.com/webbackend/api/ProductSupport/TechnicalData?language=en&region=cn&productId=377610&mlfb=5SP3763-2KK02","alternativesUrl":"https://aoctrl.com/api/mcp/products/5SP3763-2KK02/alternatives.json"},"ai":{"faq":[],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/siemens/5SP3763-2KK02","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/siemens/5SP3763-2KK02 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}