{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"5SP4180-6","brand":"Siemens","brandSlug":"siemens","productSlug":"5SP4180-6","canonicalUrl":"https://aoctrl.com/siemens/5SP4180-6","factsUrl":"https://aoctrl.com/api/mcp/products/5SP4180-6","rawCanonicalId":null},"summary":{"shortDescription":"Siemens SENTRON 5SP4180-6, miniature circuit breaker, 1-pole, B characteristic, 80 A, 10 kA per EN 60898, 230/400 V AC, depth 70 mm.","salesMarkdown":"The Siemens SENTRON 5SP4180-6 is a 1-pole miniature circuit breaker with a B tripping characteristic, rated 80 A and 10 kA breaking capacity per EN 60898 at 230/400 V AC. ## Mounting and environment Fastens via DIN rail and screw fixing; mounting position is any. IP20 with connected conductors, IP40 in the handle area with a distribution cover — adequate for enclosed panel environments where incidental contact is the concern. Degree of pollution 3 and overvoltage category 3 per the spec. ## Environmental and service life Halogen-free and silicon-free construction. Shock resistance per IEC 60068-2-27 at 150 m/s² for 11 ms half-sine; vibration resistance per IEC 60068-2-6 at 50 m/s² over 25–150 Hz and 60 m/s² at 35 Hz for 4 seconds.","metaTitle":"Siemens 5SP4180-6 SENTRON MCB, 1P B 80A 10kA","metaDescription":"Siemens SENTRON 5SP4180-6 miniature circuit breaker, 1-pole, B-curve, 80 A, 10 kA per EN 60898. Active production. Quoted to order against RFQ.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":["1-Pole MCB (DIN Rail)"],"specifications":{"Depth":"76 mm","Width":"27 mm","title":"5SP4180-6","Height":"90 mm","Maximum":"75 °C","Minimum":"-40 °C","Sealable":"Yes","description":"Miniature circuit breaker 230/400 V 10kA, 1-pole, B, 80 A, D=70 mm","Halogen-Free":"Yes","Silicon-Free":"Yes","Design Of Pole":"1P","Number Of Poles":"1","lifecycle_stage":"current","Fastening Method":"DIN rail and screw fixing","Mounting Position":"any","at AC rated value":"440 V","Installation Depth":"70 mm","Product Brand Name":"SENTRON","Degree Of Pollution":"3","Product Designation":"Miniature circuit breaker","protection class IP":"IP20 with connected conductors, IP40 in the area of the handle with distribution cover","Overvoltage Category":"3","Tunnel Terminals Top":"Yes","Design Of The Product":"5SP Miniature circuit breakers","Tunnel Terminals Bottom":"Yes","Number Of Modular Width Units":"1.5","Position Of Power Supply Cord":"Any","Tripping Characteristic Class":"B","supply voltage at AC rated value":"400 V","according to EN 60898 rated value":"10 kA","Influence Of The Surrounding Temperature":"Max. 95% rel. humidity","Type Of Voltage Of The Operating Voltage":"AC","Value Range Of The Supply Voltage Frequency":"50/60 Hz","shock resistance according to IEC 60068-2-27":"150m/s² at 11ms half-sine","with multi-phase operation at AC rated value":"440 V","with single-phase operation at AC rated value":"250 V","vibration resistance according to IEC 60068-2-6":"50m/s² at 25 to 150Hz and 60m/s² at 35Hz (4sec)","Mechanical Service Life (Operating Cycles) Typical":"10 000","Product Extension Installable Supplementary Devices":"Yes","power loss [W] for rated value of the current at AC in hot operating state per pole":"7 W"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"stockQuantity":0,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/2498559f89d3358ab4ece199d9d9adfc.pdf","sourceUrl":"https://support.industry.siemens.com/webbackend/api/ProductSupport/TechnicalData?language=en&region=cn&productId=250893&mlfb=5SP4180-6"},"ai":{"faq":[{"question":"Where can I buy 5SP4180-6 and how do I get a price?","answer":"This part is sourced and quoted to order against an RFQ through independent distribution. Submit an RFQ for current availability and pricing — no stock or price figures are published here."},{"question":"What is 5SP4180-6's listed depth (76 mm) on this component line?","answer":"The overall depth is 76 mm; the installation depth behind the panel is 70 mm."},{"question":"What is 5SP4180-6's listed width (27 mm) on this component line?","answer":"The width is 27 mm, which corresponds to 1.5 modular width units on a standard DIN-rail grid."},{"question":"Will 5SP4180-6 drop into a panel that was specified around 5SP4292-7 without rewiring?","answer":"Both are 1-pole SENTRON MCBs on the same DIN-rail footprint, so physical fit is identical. The 5SP4180-6 is a B-curve 80 A unit; the 5SP4292-7 is a C-curve unit at a different rating. Verify the tripping characteristic and ampacity match your circuit design before substitution — the mechanical swap is straightforward, but the protection coordination may differ."},{"question":"What compliance documentation does this brand provide for 5SP4180-6 (RoHS, REACH, UL, IEC)?","answer":"The part is rated per EN 60898 for breaking capacity (10 kA) and carries IEC 60068-2-27 and IEC 60068-2-6 environmental test compliance. It is halogen-free and silicon-free. For RoHS/REACH declarations and any UL listing, request the manufacturer's compliance documentation at quote time — those specifics are not in the published spec record here."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"icboms-matrix-langgraph","citationUrl":"https://aoctrl.com/siemens/5SP4180-6","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/siemens/5SP4180-6 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-08-11T15:51:03.652Z","lastPublished":"2026-08-11T15:51:03.652Z","indexable":true}}