{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"5SU1154-6KK13","brand":"Siemens","brandSlug":"siemens","productSlug":"5SU1154-6KK13","canonicalUrl":"https://aoctrl.com/siemens/5SU1154-6KK13","factsUrl":"https://aoctrl.com/api/mcp/products/5SU1154-6KK13","rawCanonicalId":null},"summary":{"shortDescription":"Siemens SENTRON 5SU1154-6KK13 RCBO, 1P+N, 13 A rated, 10 mA residual, Type A, tripping characteristic B, 10 kA breaking capacity, 2 MW.","salesMarkdown":"The 5SU1154-6KK13: Compared to a standard MCB-only device like the 5SL4363-7, this RCBO integrates the residual-current function, so it occupies the same two-module footprint but eliminates the need for a separate RCCB upstream — saving a DIN position and reducing wiring. The 10 mA trip level is lower than the common 30 mA, making it suitable for circuits where enhanced personnel protection or equipment sensitivity is specified. Depth is 77 mm, installation depth 70 mm — verify enclosure depth clearance, especially in shallow consumer units. IP20 applies when installed in a closed distribution board with connected conductors. Derating is required at elevated ambient temperatures: at 30 °C the rating is 13 A, dropping to 12.48 A at 40 °C, 11.96 A at 50 °C, and 10.01 A at 70 °C. Halogen-free and silicon-free construction suits environments sensitive to corrosive off-gassing, such as marine or offshore installations. The residual current type A detects AC and pulsating DC faults, covering most modern electronic loads.","metaTitle":"Siemens SENTRON 5SU1154-6KK13 RCBO, 13 A, 10 mA, Type A, 2 M","metaDescription":"Siemens SENTRON 5SU1154-6KK13 RCBO, 1P+N, 13 A rated, 10 mA residual, Type A, tripping characteristic B, 10 kA breaking capacity, 2 MW, active production.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":["Residual Current Breakers (RCCB/RCBO)"],"specifications":{"Depth":"77 mm","Width":"36 mm","title":"5SU1154-6KK13","Height":"90 mm","Maximum":"75 °C","Minimum":"-40 °C","description":"RCBO, 10 kA, 1P+N, type A, 10 mA, B char., In: 13 A, Un AC: 230 V","Halogen-Free":"Yes","Silicon-Free":"Yes","Design Of Pole":"1P+N","Number Of Poles":"2","lifecycle_stage":"current","Mounting Position":"any","at AC rated value":"13 A","Installation Depth":"70 mm","Product Brand Name":"SENTRON","Degree Of Pollution":"2","Operating Frequency":"50 Hz","Product Designation":"RCBO","protection class IP":"IP20, if the distribution board is installed, with connected conductors","Overvoltage Category":"III","Design Of The Product":"Instantaneous","Residual Current Type":"A","Weight With Packaging":"281 g","at 30 °C rated value":"13 A","at 40 °C rated value":"12.48 A","at 45 °C rated value":"12.22 A","at 50 °C rated value":"11.96 A","at 55 °C rated value":"11.57 A","at 60 °C rated value":"11.31 A","at 65 °C rated value":"10.53 A","at 70 °C rated value":"10.01 A","Energy Limitation Class":"3","according to EN 61346-2":"F","according to IEC 81346-2":"F","For Testing Equipment Minimum":"100 V","Number Of Modular Width Units":"2","Position Of Power Supply Cord":"Either top or bottom","Tripping Characteristic Class":"B","Number Of Poles With Protection":"1","according to EN 60898 rated value":"10 kA","Tripping Fault Current Rated Value":"10 mA","insulation voltage (Ui) rated value":"264 V","Supply Voltage Frequency Rated Value":"50 Hz","Surge Voltage Resistance Rated Value":"4 000 V","according to IEC 60947-2 rated value":"20 kA","Surge Current Resistance At (8/20) μS":"1 kA","Influence Of The Surrounding Temperature":"Max. 95% humidity","Type Of Voltage Of The Operating Voltage":"AC","Mechanical Service Life (Switching Cycles) Typical":"10 000","for rated value of the current at AC in hot operating state per pole":"3.5 W"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":"$137.69","stockQuantity":0,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/e916af55d9342e32686809c9d6f5eee0.pdf","sourceUrl":"https://support.industry.siemens.com/webbackend/api/ProductSupport/TechnicalData?language=en&region=cn&productId=489266&mlfb=5SU1154-6KK13"},"ai":{"faq":[{"question":"What is the closest functional second-source to 5SU1154-6KK13?","answer":"The 5SL4363-7 is an MCB-only device without residual current protection, so it is not a direct functional replacement. For a drop-in RCBO with the same 2-module width and 13 A rating, the 5SU1154-6KK13 is the correct Siemens order code."},{"question":"What is the depth of 5SU1154-6KK13?","answer":"The depth is 77 mm, with an installation depth of 70 mm."},{"question":"What is the width of 5SU1154-6KK13?","answer":"The width is 36 mm, which corresponds to 2 modular units (MW)."},{"question":"What compliance documentation does Siemens provide for 5SU1154-6KK13?","answer":"The part is halogen-free and silicon-free. Standard Siemens documentation includes the declaration of conformity and product data sheet. For specific RoHS, REACH, or UL certifications, consult the Siemens SENTRON technical documentation for this order code."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"icboms-matrix-langgraph","citationUrl":"https://aoctrl.com/siemens/5SU1154-6KK13","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/siemens/5SU1154-6KK13 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-08-11T15:51:03.652Z","lastPublished":"2026-08-11T15:51:03.652Z","indexable":true}}