{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"5SU1324-6FA06","brand":"Siemens","brandSlug":"siemens","productSlug":"5SU1324-6FA06","canonicalUrl":"https://aoctrl.com/siemens/5SU1324-6FA06","factsUrl":"https://aoctrl.com/api/mcp/products/5SU1324-6FA06","rawCanonicalId":null},"summary":{"shortDescription":"Siemens SENTRON 5SU1324-6FA06 RCBO, 2-pole instantaneous, B tripping characteristic, 6 A rated at 30 °C, 10 kA breaking capacity per EN 60898, 35 kA per IEC 60947-2.","salesMarkdown":"It combines a B-curve miniature circuit breaker (MCB) and a residual current device (RCD) in one 3-module-width unit. The residual current element provides earth-fault protection for personnel and equipment. The EN 60898 rating covers domestic and commercial final circuits; the IEC 60947-2 rating applies when the device is used in industrial distribution boards with higher prospective fault levels. Energy limitation class 3 keeps let-through energy low enough to protect downstream wiring. The 6 A rating is only valid at 30 °C ambient. Inside a closed distribution board, ambient temperature is often higher. At 40 °C the continuous rating drops to 5.7 A; at 50 °C to 5.4 A; at 60 °C to 5.1 A; at 70 °C to 4.62 A. Operating frequency is 50 Hz only. Supply voltage 230/240 V AC, insulation voltage 264 V. The 5SU1324-6FA06 snaps onto DIN rail (3 module widths, 54 mm wide). Mounting position is any orientation. Feed from top or bottom — no restriction. Installation depth 70 mm; total depth 77 mm. IP20 rating applies only after the distribution board is installed and conductors connected — the device itself is not sealed for exposed locations. Halogen-free and silicon-free construction, important for clean-room or corrosive-environment installations where outgassing contaminates contacts or optics.","metaTitle":"Siemens 5SU1324-6FA06 SENTRON RCBO, B Curve 6 A, 10 kA","metaDescription":"Siemens 5SU1324-6FA06 SENTRON RCBO, 2-pole, B curve, 6 A at 30 °C, 10 kA (EN 60898). Current production. Quoted to order. Request RFQ.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":["Residual Current Breakers (RCCB/RCBO)"],"specifications":{"Depth":"77 mm","Width":"54 mm","Height":"90 mm","Maximum":"75 °C","Minimum":"-40 °C","Halogen-Free":"Yes","Silicon-Free":"Yes","Design Of Pole":"2P","Number Of Poles":"2","lifecycle_stage":"current","Mounting Position":"any","at AC rated value":"230/240 V","Installation Depth":"70 mm","Product Brand Name":"SENTRON","Degree Of Pollution":"2","Operating Frequency":"50 Hz","Product Designation":"RCBO","protection class IP":"IP20, if the distribution board is installed, with connected conductors","Overvoltage Category":"III","Design Of The Product":"Instantaneous","Weight With Packaging":"424 g","at 30 °C rated value":"6 A","at 40 °C rated value":"5.7 A","at 45 °C rated value":"5.58 A","at 50 °C rated value":"5.4 A","at 55 °C rated value":"5.22 A","at 60 °C rated value":"5.1 A","at 65 °C rated value":"4.86 A","at 70 °C rated value":"4.62 A","Energy Limitation Class":"3","For Testing Equipment Minimum":"195 V","Number Of Modular Width Units":"3","Position Of Power Supply Cord":"Either top or bottom","Tripping Characteristic Class":"B","Number Of Poles With Protection":"2","according to EN 60898 rated value":"10 kA","insulation voltage (Ui) rated value":"264 V","Supply Voltage Frequency Rated Value":"50 Hz","Surge Voltage Resistance Rated Value":"4 000 V","according to IEC 60947-2 rated value":"35 kA","Surge Current Resistance At (8/20) μS":"1 kA","Influence Of The Surrounding Temperature":"Max. 95% humidity","Type Of Voltage Of The Operating Voltage":"AC","Mechanical Service Life (Operating Cycles) Typical":"10 000"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/f8a3f804604e34cc21a3fa836405929c.pdf","sourceUrl":"https://support.industry.siemens.com/webbackend/api/ProductSupport/TechnicalData?language=en&region=cn&productId=25966&mlfb=5SU1324-6FA06","alternativesUrl":"https://aoctrl.com/api/mcp/products/5SU1324-6FA06/alternatives.json"},"ai":{"faq":[{"question":"How do I get current pricing and availability for 5SU1324-6FA06?","answer":"Submit an RFQ — the part is sourced through independent distribution and quoted to order. Availability and current pricing are confirmed at quote time."},{"question":"What is 5SU1324-6FA06's listed depth (77 mm) on this component line?","answer":"Total depth is 77 mm; installation depth (behind the panel face) is 70 mm."},{"question":"What is 5SU1324-6FA06's listed width (54 mm) on this component line?","answer":"Width is 54 mm, which corresponds to 3 modular DIN-rail units (each 18 mm)."},{"question":"What compliance documentation does this brand provide for 5SU1324-6FA06 (RoHS, REACH, UL, IEC)?","answer":"The device is designed to EN 60898 and IEC 60947-2. Halogen-free and silicon-free construction is declared. For specific RoHS/REACH/UL declarations, request the manufacturer's compliance documentation through an RFQ."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/siemens/5SU1324-6FA06","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/siemens/5SU1324-6FA06 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}