{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"5SU1324-6FA16","brand":"Siemens","brandSlug":"siemens","productSlug":"5SU1324-6FA16","canonicalUrl":"https://aoctrl.com/siemens/5SU1324-6FA16","factsUrl":"https://aoctrl.com/api/mcp/products/5SU1324-6FA16","rawCanonicalId":null},"summary":{"shortDescription":"Siemens SENTRON 5SU1324-6FA16 RCBO, 2-pole, type A, 30 mA, B-curve, In 16 A, Un AC 230 V, 10 kA (EN 60898) / 20 kA (IEC 60947-2).","salesMarkdown":"The Siemens SENTRON 5SU1324-6FA16 is a 2-pole RCBO combining overcurrent protection (B-curve, 16 A) and residual current detection (type A, 30 mA) in a single 3-module-width package. It is rated for 230/240 V AC at 50 Hz, with a breaking capacity of 10 kA per EN 60898 and 20 kA per IEC 60947-2. ## Panel fit and mounting constraints Mounting position is any orientation. The IP20 rating applies only when the distribution board is installed with connected conductors — the RCBO itself is not sealed against dust ingress before panel integration. Supply can enter from top or bottom. ## Breaking capacity: what the dual rating means The 10 kA rating per EN 60898 is the standard for household and similar installations.","metaTitle":"Siemens 5SU1324-6FA16 SENTRON RCBO, 16A B-curve 30mA, 2P","metaDescription":"Siemens SENTRON 5SU1324-6FA16 RCBO, 16A, B-curve, 30mA residual current, 2-pole, 10kA (EN 60898) / 20kA (IEC 60947-2). Active production. Quoted to order.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":["Residual Current Breakers (RCCB/RCBO)"],"specifications":{"Depth":"77 mm","Width":"54 mm","Height":"90 mm","Maximum":"75 °C","Minimum":"-40 °C","Halogen-Free":"Yes","Silicon-Free":"Yes","Design Of Pole":"2P","Number Of Poles":"2","lifecycle_stage":"current","Mounting Position":"any","at AC rated value":"230/240 V","Installation Depth":"70 mm","Product Brand Name":"SENTRON","Degree Of Pollution":"2","Operating Frequency":"50 Hz","Product Designation":"RCBO","protection class IP":"IP20, if the distribution board is installed, with connected conductors","Overvoltage Category":"III","Design Of The Product":"Instantaneous","Weight With Packaging":"408 g","Energy Limitation Class":"3","For Testing Equipment Minimum":"195 V","Number Of Modular Width Units":"3","Position Of Power Supply Cord":"Either top or bottom","Tripping Characteristic Class":"B","Number Of Poles With Protection":"2","according to EN 60898 rated value":"10 kA","insulation voltage (Ui) rated value":"264 V","Supply Voltage Frequency Rated Value":"50 Hz","Surge Voltage Resistance Rated Value":"4 000 V","according to IEC 60947-2 rated value":"20 kA","Surge Current Resistance At (8/20) μS":"1 kA","Influence Of The Surrounding Temperature":"Max. 95% humidity","Type Of Voltage Of The Operating Voltage":"AC","Mechanical Service Life (Operating Cycles) Typical":"10 000"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/f8a3f804604e34cc21a3fa836405929c.pdf","sourceUrl":"https://support.industry.siemens.com/webbackend/api/ProductSupport/TechnicalData?language=en&region=cn&productId=348744&mlfb=5SU1324-6FA16","alternativesUrl":"https://aoctrl.com/api/mcp/products/5SU1324-6FA16/alternatives.json"},"ai":{"faq":[{"question":"Where can I buy 5SU1324-6FA16 and how do I get a price?","answer":"The part is sourced and quoted to order against an RFQ through independent distribution. Availability and current pricing are confirmed at quote time."},{"question":"Will 5SU1324-6FA16 drop into a panel specified around 5SU9354-7KK16 without rewiring?","answer":"No — the 5SU9354-7KK16 is a 1P+N unit (2 modules wide) with C-curve and 10 kA breaking capacity, while the 5SU1324-6FA16 is a 2-pole unit (3 modules wide) with B-curve and a 20 kA IEC 60947-2 rating. The width difference (54 mm vs 36 mm) means it will not fit the same DIN-rail slot without re-spacing the panel layout."},{"question":"What is 5SU1324-6FA16's listed depth?","answer":"The overall depth is 77 mm; the installation depth behind the panel face is 70 mm."},{"question":"What compliance documentation does this brand provide?","answer":"The SENTRON series RCBO is designed to EN 60898 and IEC 60947-2. The unit is halogen-free and silicon-free. Specific RoHS/REACH/UL declarations are manufacturer-issued documents; the product carries CE marking for the European market."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/siemens/5SU1324-6FA16","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/siemens/5SU1324-6FA16 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}