{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"5SU1324-7FM16","brand":"Siemens","brandSlug":"siemens","productSlug":"5SU1324-7FM16","canonicalUrl":"https://aoctrl.com/siemens/5SU1324-7FM16","factsUrl":"https://aoctrl.com/api/mcp/products/5SU1324-7FM16","rawCanonicalId":null},"summary":{"shortDescription":"Siemens SENTRON 5SU1 series RCBO, 2-pole, 16 A rated at 30 °C, 10 kA breaking capacity per EN 60898, Type A fault current, 230/240 V AC, 50 Hz, C characteristic, instantaneous design.","salesMarkdown":"The Siemens 5SU1324-7FM16 is a 2-pole RCBO (residual current circuit breaker with overcurrent protection) from the SENTRON 5SU1 series, combining a Type A residual current device and a C-characteristic miniature circuit breaker in a single 3-module-wide unit (54 mm). It's rated for 230/240 V AC at 50 Hz, with a 10 kA breaking capacity per EN 60898 — the standard for household and similar installations, certifying its ability to safely interrupt fault currents up to that level. The C tripping curve means it's designed for inductive loads like small motors, pumps, and lighting banks where inrush current can exceed 5× the rated current. The headline 16 A rating holds only at 30 °C ambient. In a sealed distribution board running at 40 °C — common in summer or crowded enclosures — the continuous current drops to 15.2 A. At 50 °C it's 14.4 A, and at 60 °C it's 13.6 A. If your panel ambient hits 70 °C, derate to 12.32 A. This is the number that governs real-world loading, not the 30 °C figure. For a pump drawing 14 A continuous at 45 °C, the 14.88 A derated value leaves only 0.88 A headroom — marginal for a circuit that won't nuisance-trip on a hot day. ## Type A fault current detection — what it catches If your downstream loads include any electronics that chop the sine wave, Type A is the minimum for code compliance in most IEC regions. The instantaneous design (no intentional time delay) means it trips within the standard RCD response time — no coordination with delayed RCDs upstream. ## Halogen-free and silicon-free construction Both the housing and internal insulation are halogen-free and silicon-free. That matters for installations in environments where outgassing from a fault arc could corrode nearby contacts — think data centers, medical equipment, or clean rooms.","metaTitle":"Siemens 5SU1324-7FM16 SENTRON RCBO, 16 A, 10 kA, Type A, 2-p","metaDescription":"Siemens 5SU1324-7FM16 SENTRON RCBO, 16 A rated at 30 °C, 10 kA breaking capacity per EN 60898, Type A fault current, 2-pole, 230/240 V AC, 50 Hz. Sourced to order against RFQ.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":null,"categoryPath":[],"specifications":{"Depth":"77 mm","Poles":"2","Width":"54 mm","Height":"90 mm","Product Status":"Active"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/f8a3f804604e34cc21a3fa836405929c.pdf","sourceUrl":"https://support.industry.siemens.com/webbackend/api/ProductSupport/TechnicalData?language=en&region=cn&productId=537958&mlfb=5SU1324-7FM16","alternativesUrl":"https://aoctrl.com/api/mcp/products/5SU1324-7FM16/alternatives.json"},"ai":{"faq":[],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/siemens/5SU1324-7FM16","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/siemens/5SU1324-7FM16 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}