{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"5SU1324-7FP32","brand":"Siemens","brandSlug":"siemens","productSlug":"5SU1324-7FP32","canonicalUrl":"https://aoctrl.com/siemens/5SU1324-7FP32","factsUrl":"https://aoctrl.com/api/mcp/products/5SU1324-7FP32","rawCanonicalId":null},"summary":{"shortDescription":"Siemens SENTRON 5SU1324-7FP32 RCBO, 2-pole, 32 A rated, 30 mA residual current type A, tripping characteristic C, 10 kA (EN 60898) / 15 kA (IEC 60947-2).","salesMarkdown":"## RCBO for panel protection — 32 A, 30 mA residual, type C The Siemens 5SU1324-7FP32 is a 2-pole RCBO (residual current circuit breaker with overcurrent protection) from the SENTRON series, combining a 32 A MCB with type C tripping characteristic and a 30 mA residual current device type A in a single 36 mm wide module. The 30 mA residual sensitivity (type A) handles pulsating DC fault currents from electronics loads — common in modern lighting, IT equipment, and small drives — so it's suited for general-purpose final circuits rather than pure sine-wave AC-only installations. Full rated current of 32 A holds at 30 °C ambient; at 40 °C it derates to 30.8 A, at 50 °C to 29.5 A, and at 60 °C to 28.8 A (–). That matters when the RCBO sits in a crowded enclosure with multiple heat sources — the actual continuous load should stay under the derated figure for the enclosure's internal temperature. Mounting position is unrestricted, and the supply can enter from either top or bottom. Rated insulation voltage (Ui) is 500 V. Energy limitation class 3 and touch protection fitted. The product designation per IEC 81346-2 and DIN EN 61346-2 is F. Operating frequency is 50 Hz. IP20 with connected conductors in an installed distribution board.","metaTitle":"Siemens 5SU1324-7FP32 SENTRON RCBO, 2-Pole, Type C, 32A, 30m","metaDescription":"Siemens SENTRON 5SU1324-7FP32 RCBO, 2-pole, 32A, 30mA residual current type A, tripping characteristic C. Breaking capacity 10kA (EN 60898) / 15kA (IEC 60947-2). Current-production","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":["Residual Current Breakers (RCCB/RCBO)"],"specifications":{"Depth":"72 mm","Width":"36 mm","Height":"85 mm","Maximum":"70 °C","Minimum":"-40 °C","Halogen-Free":"No","Number Of Poles":"2","lifecycle_stage":"current","Mounting Position":"Any","Installation Depth":"70 mm","Product Brand Name":"SENTRON","Degree Of Pollution":"3","Operating Frequency":"50 Hz","Product Designation":"RCBO","acc. to IEC 81346-2":"F","at AC / rated value":"32 A","protection class IP":"IP20, if the distribution board is installed, with connected conductors","Overvoltage Category":"III","Design Of The Product":"Instantaneous","Residual Current Type":"A","acc. to DIN EN 61346-2":"F","Energy Limitation Class":"3","Weight / With Packaging":"264 g","at 30 °C / rated value":"32 A","at 40 °C / rated value":"30.8 A","at 45 °C / rated value":"30.2 A","at 50 °C / rated value":"29.5 A","at 55 °C / rated value":"29.2 A","at 60 °C / rated value":"28.8 A","Number Of Modular Width Units":"2","Tripping Characteristic Class":"C","acc. to EN 60898 / rated value":"10 kA","For Testing Equipment / Minimum":"195 V","Position / Of Power Supply Cord":"Either top or bottom","Number Of Poles / With Protection":"2","acc. to IEC 60947-2 / rated value":"15 kA","Product Feature / Touch Protection":"Yes","Tripping Fault Current / Rated Value":"30 mA","insulation voltage (Ui) / rated value":"500 V","Supply Voltage Frequency / Rated Value":"50 Hz","Surge Voltage Resistance / Rated Value":"4 000 V","Influence Of The Surrounding Temperature":"Max. 95% humidity","Surge Current Resistance / At (8/20) μS":"0.25 kA","Type Of Voltage / Of The Operating Voltage":"AC","Product Component / Neutral Conductor Switching":"Yes","Mechanical Service Life (Switching Cycles) / Typical":"10 000"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/f8a3f804604e34cc21a3fa836405929c.pdf","sourceUrl":"https://support.industry.siemens.com/webbackend/api/ProductSupport/TechnicalData?language=en&region=cn&productId=1108784&mlfb=5SU1324-7FP32","alternativesUrl":"https://aoctrl.com/api/mcp/products/5SU1324-7FP32/alternatives.json"},"ai":{"faq":[{"question":"Where can I buy 5SU1324-7FP32 and how is it quoted?","answer":"This part is sourced and quoted to order against an RFQ through independent distribution. Availability and current pricing are confirmed at quote time — no stock or price figures are published here."},{"question":"What are the key ratings of 5SU1324-7FP32?","answer":"32 A rated current, 30 mA residual current type A, tripping characteristic C, 2-pole, breaking capacity 10 kA (EN 60898) / 15 kA (IEC 60947-2)."},{"question":"What is the width and depth of 5SU1324-7FP32?","answer":"Width is 36 mm (2 modular units), depth is 72 mm, installation depth is 70 mm."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/siemens/5SU1324-7FP32","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/siemens/5SU1324-7FP32 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}