{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"5SU1324-7KK82","brand":"Siemens","brandSlug":"siemens","productSlug":"5SU1324-7KK82","canonicalUrl":"https://aoctrl.com/siemens/5SU1324-7KK82","factsUrl":"https://aoctrl.com/api/mcp/products/5SU1324-7KK82","rawCanonicalId":null},"summary":{"shortDescription":"Siemens SENTRON 5SU1324-7KK82, 2-pole RCBO, 125 A rated current, 30 mA Type A residual current, C characteristic, 10 kA breaking capacity, 50 Hz.","salesMarkdown":"The Siemens SENTRON 5SU1324-7KK82 is a 2-pole residual current circuit breaker with overcurrent protection (RCBO) rated at 125 A with a 30 mA Type A residual current trip and C-curve tripping characteristic. It breaks fault currents up to 10 kA per EN 60898 and IEC 60947-2, so it handles both the overcurrent and ground-fault protection in a single 7-module-wide unit on the DIN rail. At 40 °C it derates to 115.62 A, at 45 °C to 111.25 A, at 50 °C to 106.25 A, at 55 °C to 101.25 A, and at 60 °C to 96.25 A. If your panel runs hot — say 50 °C inside a sealed cabinet — you need to size the upstream breaker for 106 A, not 125 A. The 30 mA Type A residual current trip catches sinusoidal AC faults and pulsating DC faults. The C-curve suits motor and lighting loads with moderate inrush. Breaking capacity is 10 kA under both EN 60898 and IEC 60947-2, meaning it can safely interrupt a 10 kA prospective fault current at the installation point. The insulation voltage is rated 264 V, and overvoltage category III applies — suitable for fixed-installation distribution boards downstream of the main panel. It occupies 7 modular width units (roughly 123 mm on the rail). Depth is 77 mm, width 117 mm, height 90 mm, with an installation depth of 70 mm behind the panel face. Pollution degree 2 (non-conductive pollution with occasional condensation) is the standard for most commercial and light-industrial distribution boards.","metaTitle":"Siemens 5SU1324-7KK82 SENTRON RCBO, 125 A, 30 mA, Type A, 10","metaDescription":"Siemens SENTRON 5SU1324-7KK82 RCBO, 2-pole, 125 A rated, 30 mA Type A residual current, 10 kA breaking capacity (EN 60898 / IEC 60947-2). Current lifecycle. Quoted to order.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":["Residual Current Breakers (RCCB/RCBO)"],"specifications":{"Depth":"77 mm","Width":"117 mm","Height":"90 mm","Maximum":"75 °C","Minimum":"-40 °C","Halogen-Free":"Yes","Silicon-Free":"Yes","Number Of Poles":"2","lifecycle_stage":"current","Mounting Position":"any","Installation Depth":"70 mm","Product Brand Name":"SENTRON","Degree Of Pollution":"2","Operating Frequency":"50 Hz","Product Designation":"RCBO","acc. to IEC 81346-2":"F","at AC / rated value":"125 A","protection class IP":"IP20, if the distribution board is installed, with connected conductors","Overvoltage Category":"III","Design Of The Product":"Instantaneous","Residual Current Type":"A","acc. to DIN EN 61346-2":"F","Energy Limitation Class":"3","Weight / With Packaging":"1 212 g","at 30 °C / rated value":"125 A","at 40 °C / rated value":"115.62 A","at 45 °C / rated value":"111.25 A","at 50 °C / rated value":"106.25 A","at 55 °C / rated value":"101.25 A","at 60 °C / rated value":"96.25 A","Number Of Modular Width Units":"7","Tripping Characteristic Class":"C","acc. to EN 60898 / rated value":"10 kA","For Testing Equipment / Minimum":"195 V","Position / Of Power Supply Cord":"Either top or bottom","Number Of Poles / With Protection":"2","acc. to IEC 60947-2 / rated value":"10 kA","Product Feature / Touch Protection":"Yes","Tripping Fault Current / Rated Value":"30 mA","insulation voltage (Ui) / rated value":"264 V","Supply Voltage Frequency / Rated Value":"50 Hz","Surge Voltage Resistance / Rated Value":"4 000 V","Influence Of The Surrounding Temperature":"Max. 95% humidity","Surge Current Resistance / At (8/20) μS":"1 kA","Type Of Voltage / Of The Operating Voltage":"AC","Product Component / Neutral Conductor Switching":"Yes","Mechanical Service Life (Switching Cycles) / Typical":"10 000"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/f8a3f804604e34cc21a3fa836405929c.pdf","sourceUrl":"https://support.industry.siemens.com/webbackend/api/ProductSupport/TechnicalData?language=en&region=cn&productId=46413&mlfb=5SU1324-7KK82","alternativesUrl":"https://aoctrl.com/api/mcp/products/5SU1324-7KK82/alternatives.json"},"ai":{"faq":[],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/siemens/5SU1324-7KK82","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/siemens/5SU1324-7KK82 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}