{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"5SU1336-6FP06","brand":"Siemens","brandSlug":"siemens","productSlug":"5SU1336-6FP06","canonicalUrl":"https://aoctrl.com/siemens/5SU1336-6FP06","factsUrl":"https://aoctrl.com/api/mcp/products/5SU1336-6FP06","rawCanonicalId":null},"summary":{"shortDescription":"Siemens SENTRON 5SU1336-6FP06 RCBO, 3-pole, 6 A, B characteristic, 30 mA residual current, 6 kA breaking capacity.","salesMarkdown":"The 5SU1336-6FP06: 6 A at 30 °C ambient, derated to 5.7 A at 40 °C and 5 A at 60 °C — the thermal curve matters if this lives in a warm enclosure. B curve means magnetic trip between 3 and 5 times In (18–30 A), so it's sized for resistive or lightly inductive loads, not motor starts. 6 kA breaking capacity per EN 60898 covers most domestic and light commercial fault levels. Type A residual detects AC and pulsating DC faults, which is the standard for circuits with electronics or single-phase rectifiers. ## Panel fit and installation Three modular-width units (54 mm wide) on DIN rail. Depth is 72 mm, installation depth 70 mm — check your enclosure depth if you're retrofitting into a shallow gland plate. Mounting position any, supply feed either top or bottom. IP20 with the distribution board installed and conductors connected — not for open-panel washdown areas. No official successor because none is needed.","metaTitle":"Siemens 5SU1336-6FP06 SENTRON RCBO, 3P, 6A, B Curve, 30mA","metaDescription":"Siemens 5SU1336-6FP06 SENTRON RCBO, 3-pole, 6 A rated, B tripping curve, 30 mA residual current, 6 kA breaking capacity. Current production. Available to order.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":["Residual Current Breakers (RCCB/RCBO)"],"specifications":{"Depth":"72 mm","Width":"54 mm","Height":"85 mm","Maximum":"70 °C","Minimum":"-40 °C","Halogen-Free":"No","Design Of Pole":"3P","Number Of Poles":"3","lifecycle_stage":"current","Mounting Position":"Any","Installation Depth":"70 mm","Product Brand Name":"SENTRON","Degree Of Pollution":"3","Operating Frequency":"50 Hz","Product Designation":"RCBO","at AC / rated value":"6 A","protection class IP":"IP20, if the distribution board is installed, with connected conductors","Overvoltage Category":"III","Design Of The Product":"Instantaneous","Residual Current Type":"A","Energy Limitation Class":"3","Weight / With Packaging":"428 g","according to EN 61346-2":"F","at 30 °C / rated value":"6 A","at 40 °C / rated value":"5.7 A","at 45 °C / rated value":"5.5 A","at 50 °C / rated value":"5.3 A","at 55 °C / rated value":"5.1 A","at 60 °C / rated value":"5 A","according to IEC 81346-2":"F","Number Of Modular Width Units":"3","Tripping Characteristic Class":"B","For Testing Equipment / Minimum":"340 V","Position / Of Power Supply Cord":"Either top or bottom","Number Of Poles / With Protection":"3","according to EN 60898 / rated value":"6 kA","Tripping Fault Current / Rated Value":"30 mA","insulation voltage (Ui) / rated value":"500 V","Supply Voltage Frequency / Rated Value":"50 Hz","Surge Voltage Resistance / Rated Value":"4 000 V","according to IEC 60947-2 / rated value":"6 kA","Influence Of The Surrounding Temperature":"Max. 95% humidity","Surge Current Resistance / At (8/20) μS":"0.25 kA","Type Of Voltage / Of The Operating Voltage":"AC","Mechanical Service Life (Switching Cycles) / Typical":"10 000"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/da928dc0b5f4a44ce49c21ad3c81893a.pdf","sourceUrl":"https://support.industry.siemens.com/webbackend/api/ProductSupport/TechnicalData?language=en&region=cn&productId=1438037&mlfb=5SU1336-6FP06","alternativesUrl":"https://aoctrl.com/api/mcp/products/5SU1336-6FP06/alternatives.json"},"ai":{"faq":[{"question":"Where can I buy 5SU1336-6FP06?","answer":"Sourced and quoted to order against an RFQ through independent distribution; availability and current pricing confirmed at quote time."},{"question":"What is the difference between 5SU1336-6FP06 and 5SY4332-7CV?","answer":"5SY4332-7CV is a Siemens 5SY MCB only — no residual current protection. The 5SU1336-6FP06 is an RCBO combining overcurrent and 30 mA residual protection in one unit. They share the same 3-pole, 6 A, B-curve footprint, but the 5SU adds the RCD function, so it won't drop into a panel wired for a plain MCB without adding the neutral and test circuit."},{"question":"What is the depth of 5SU1336-6FP06?","answer":"72 mm overall depth, 70 mm installation depth behind the panel face."},{"question":"What is the width of 5SU1336-6FP06?","answer":"54 mm, which is three modular-width units on standard DIN rail."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/siemens/5SU1336-6FP06","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/siemens/5SU1336-6FP06 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}